Elara Max Hardware Workflow
This video introduces you to the system components of the MOBILETT Elara
Max system.
Welcome to the Mobylette Elara Max hardware workflow video. In this video you will learn how to handle the hardware components of the mobile at ihlara. Before you start moving the system, ensure the system is sufficiently charged. Disconnect the network cable if applicable. Pull the power cable out of the wall outlet. Briefly pull on the cable to trigger the automatic cable rewind. Hold the power plug in one hand while the cable is rewinding to move the system with motorized support. Press the safety switch at the back of the handle for changing the direction. Press the safety switch and start walking forward. Or backward while holding the drive handle with both hands, you can determine the movement speed by changing the pressure on the handle. Move the system with caution to avoid collisions and slow down the movement when you enter a room to park the system at the required spot, release the handle. The system will stop automatically. Position the system next to the patient's bed. Release the articulated arm and lift the X Ray tube assembly to protect the patient from the radiation. Apply a lead apron on the area not being exposed before starting the examination. Verify the patient's identity an select the patient from the work list. If necessary, select a different detector in the examination task card in case the detector set as default. Is not appropriate. The status LED of the newly selected detector will change from orange to green, position the appropriate detector according to the examination needs. For example, place the detector underneath the patients back for an AP projection of the long in line position for the positioning of the tube, always use the handles. Turn the collimator adjustment knobs to set the collimator light. In order to make fine movement adjustments of the articulated arm, press, the microinch mover buttons. If the status indicator light on the articulated arm lights up green, the system is ready for radiation release. Take the hand switch or the optional remote control an step away from the system as far as possible to protect yourself from radiation. Ensure that there are no unprotected persons near the patient. Before you press the exposure button, activate the preparation phase by pressing the radiation preparation button on the remote control. After the acoustic signal press, the exposure released Button to acquire the image. It is also possible to release radiation with the hand switch to activate the preparation phase, press the radiation released button to the first pressure point after the acoustic signal press the radiation release button to the second pressure point. The status indicator light on the articulated arm will change from green to yellow during irradiation. The end of an exposure is indicated by a longer acoustic signal. As soon as the image has been acquired and processed, it will be displayed in the image area of the screen. Remove the detector clean and disinfected before the examination of the next patient before you put the detector back in the detector Holder, ensure that the back of the detector is completely dry. Use the detector cover to protect the detector from fluids when needed, as the detector is not waterproof. As soon as the detector has been inserted into the detector Holder, the battery starts charging and the LED starts blinking green. Fold the articulated arm down an secure it with the transport safety lock. When you have finished your workflow, clean and disinfect the cover of the mobile at Ihlara, Max thoroughly. To ensure that the system is ready for use at all times, reconnected to the power supply after the examinations have been completed.
MOBILETT ELara Max VFIO MOBILETT Max VFIO Copyright @ Siemens Healthcare GmbH, 2018 Workflow Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. SIEMENS This material is to be used as training material only and shall by no means substitute the Operator Hardware Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. Healthineers SIEMENS SIEMENS . The Operator Manual shall be used as your main reference, in particular for relevant safety Healthineers information like warnings and cautions. 1 Pressure Point 2, Pressure Point Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as Healthineers The reproduction, transmission or distribution of this training or its contents is not permitted without well as standard and optional features that do not always have to be present in individual cases. express written authority. Offenders will be liable for damages. Certain products, product related claims or functionalities described in the material (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to All names and data of patients, parameters and configuration dependent designations are fictional and regulatory requirements, the future availability of said Functionalities in any specific country is not To activate the preparation phase examples only. To release radiation guaranteed. Please contact your local Siemens Healthineers sales representative for the most All rights, including rights created by patent grant or registration of a utility model or design, are reserved. current information. SIEMENS . Healthineers SIEMENS SIEMENS Healthineers
- Elara Max Hardware Workflow