EmboGuidance VB15
EmboGuidance VB15
EmboGuidance - VB15 aka CVM - Color Vessel Mapping Interventional Radiography: Vascular Please refer to manual for complete system capability at www.siemenslearningcenter.com. 1. A 3D volume has been loaded or acquired into InSpace tab. NOTE: Fusion can be performed and this volume can be loaded into InSpace 2. From the XRAY subtask card, select the EmboGuidance icon. The screen is then changed to a 4 on 1 display format. An additional gray box is opened called AX Emboguidance. 3. Complete Step 1: Identify Vessel. Left click on at least 2 points within the vessel in any MPR view. Marking order does not matter and more than one MPR view can be used to plot seed points. These seed points will display in all views. To verify positioning, scroll through the MPR's or rotate VRT. AX Embolization Guidance Step 1. Identity Vessel Mark the Vessel by selecting more points Then continue to Step 2 Threshold (430 .. 1093) 430 Use InSpace Table Ramp Close Help Any time prior to Step Two, you may manipulate the volume to better locate the desired points of interest. The display will be updated according to the manipulation performed. SIEMENS siemens.com/healthineers Healthineers Job Aid | EmboGuidance -- VB15 aka CVM-Color Vessel Mapping Effective Date: 09/06/2016 | Quality HOOD0516200894002 4. Complete Step 2: Display (vessel tree) Choose options regarding the display of centerline, seed points, bifurcations, etc. AX Embolization Guidance x Step 1: Identify Vessel Step 2: Display i To add or modify Seed Points return to Step 1. Use iPilot for Overlay. Show Centerline Seed Points Bifurcations ~ 3D Volume Centerline Live Close Help 09:38:06 AX 5. iPilot functions can now be performed. Live Close Help Siemens Healthineers Services Page 2 of 3 Job Aid | EmboGuidance -- VB15 aka CVM-Color Vessel Mapping Effective Date: 09/06/2016 | Quality HOOD0516200894002 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3
- Artis Q
- Artis zee
- Artis zeego
- Artis Zen