epoc® eDM Lite Operating The Software Job Aid
This job aid provides the instructions on how to operate the eDM Lite software.
Operating the EDM Lite Software Job Aid epoc® eDM Lite The EDM Lite software has a convenient user interface that displays the list of test records on the left and the selected record’s test results on the right. Displaying specific test result types: 1. Select the patients or QA radio buttons on the top of the screen to toggle between test results and QA results 2. Search for test results using the find field by entering a patient ID (blood test), Lot ID (QA test), Operator ID, Host or Reader name, Host or Reader serial number epoc EDM Lite (1.4.5.17984) 2 Find From 11-Apr To 17-Nov-2018 Export Thermal QA Records EQC Records Settings Patient tests 1 O Patients @ CA Results Date/Time Patiert ID Host name Reader Statue Export Analyte Recult Unit Roportable Reference Critical name Statue range range range 11-May-2017 12:20:21 014 15065521400642 8589 OK pl > 7.5 ... 7.000 - 7.500 7.100 - 7.400 7.000 - 7.500 Critical high 11 May 2017 12:10:30 013 15065521100612 8589 OK pCO2 9.1 mmHg 5.0 - 250.0 35.0 - 48.0 5.1 - 200.0 Low 11-May-2017 12:01:18 017 15065521400642 8589 OK p02 207.4 mmHg 80.0 659.0 83.0 108.0 4.0 751.0 High 11-May-2017 11:48:25 011 15065521400642 8589 OK Na+ 155 mmol ... 85 - 180 86 - 150 84 - 181 High K + 1.1 mmol ... 1.5 - 12.0 3.5 - 4.5 0.5 - 13.0 CI- 117 mmol ... 65 - 140 98 - 107 64 - 141 High Ca++ 1.15 mmol ... 0.25 - 4.00 1.15 - 1.33 0.00 - 5.00 Glu 74 mg/dl 20 - 700 74 - 100 19 - 701 I ac 7:35 mmol ... 0.30 - 20.00 0.56 - 1.39 0.00 - 71.00 High Crea 1.39 mg/dL 0.30 - 15.00 0.51 - 1.19 0.00 - 16.00 I ligh Hct < 10 % 10 - 15 38 - 51 9 - 16 Low A 154.7 mmHg 5.0 800.0 4.0 801.0 4.0 801.0 A-a < 1.0 mmHg 1.0 - 800.0 0.0 - 801.0 0.0 - 801.0 a/A > 10 ... % 0.0 - 100.0 -1.0 - 101.0 -1.0 - 101.0 pH(T) cnc 7.000 - 7.500 7.100 - 7.400 7.000 - 7.500 pC02(T) 5.3 mmHg 5.0 - 250.0 35.0 - 48.0 5.1 - 200.0 Low pO2(T) 152.8 mmHy 80.0 - 659.0 83.0 - 108.0 4.0 - 751.0 High A(T) 164.1 mmHg 5.0 - 800.0 4.0 - 801.0 4.0 - 801.0 A-a(T) 11.3 mmllg 1.0 - 800.0 0.0 - 801.0 0.0 - 801.0 a/A(1) 93.1 % 0.0 - 100.0 -1.0 - 101.0 -1.0 - 101.0 Patient Test Info Sample Equipment Respiratory Settings Records (4 of 5) Page 1 of 1 Link status . Wi-Fi Link listening on 192.168.56.1:13255 Bluetooth listening on 60:F6:77:6B:93:A5 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 SIEMENS Master Template Effective Date: 3/11/2019 | HOOD05162002998095 Healthineers Job Aid Effective Date: 24-JUL-2019 | HOOD05162003023786 Job Aid | eDM Lite Operating The Software Effective Date: 24-JUL-2019 | HOOD05162003023876 Displaying test results within a specific date range: 1. Select a date from the To and From section at the top of the screen 2. Tests records for the selected date range will be displayed in the Tests table and arranged in five columns: Date / Time, Patient ID (QA Lot), Host name, Reader name, Status. Radio button should be pressed to conveniently print or export the records 3. Click on a test record to display the test results in the Results table 1 3 epoc EDM Lite (1.4.5.1798 From 11-Apr-2017 To 17-Nov-2018 Export Thermal QA Records EQC Records Settings Patient tests Patients @ CA Results 2 Date/Time Patiert ID Host name Rcador Statue Export Analyte Recult Unit Rcportable Reference Critical name range range range Statue 11-May-2017 12:20:21 014 15065521400642 8589 OK pll > 7.5 ... 7.000 - 7.500 7.100 - 7.400 7.000 - 7.500 Critical high 11 May 2017 12:10:30 013 15065521100612 8589 OK pCO2 9.1 mmHg 5.0 - 250.0 35.0 - 48.0 5.1 - 200.0 Low 11-May-2017 12:01:18 017 15065521400642 8589 OK po2 207.4 mmHg 80.0 659.0 83.0 108.0 4.0 751.0 High 11-May-2017 11:48:25 011 15065521400642 155 mmol ... 85 - 180 86 - 150 84 - 181 8589 OK Na+ High K + 1.1 mmol ... 1.5 - 12.0 3.5 - 4.5 0.5 - 13.0 CI - 117 mmol ... 65 - 140 98 - 107 64 - 141 High Ca+ 1.15 mmol ... 0.25 - 4.00 1.15 - 1.33 0.00 - 5.00 Glu 74 my/dl 20 - 700 74 - 100 19 - 701 lar 735 mmol ... 030 - 20.00 0:56 - 1.39 0.00 - 71.00 High Crea 1.39 mg/dl 0.30 - 15.00 0.51 - 1.19 0.00 - 16.00 I ligh Hct < 10 % 10 - 75 38 - 51 9 - 76 Low A 154.7 mmHg 5.0 800.0 4.0 801.0 4.0 801.0 A-a < 1.0 mmHg 1.0 - 800.0 0.0 - 801.0 0.0 - 801.0 a/A > 10 ... % 0.0 - 100.0 -1.0 - 101.0 -1.0 - 101.0 pH(T) cnc 7.000 - 7.500 7.100 - 7.400 7.000 - 7.500 pCO2(T) 5.3 mmHg 5.0 - 250.0 35.0 - 48.0 5.1 - 200.0 Low pO2(T) 152.8 mmHy 80.0 - 659.0 83.0 - 108.0 4.0 - 751.0 High A(T) 164.1 mmHg 5.0 - 800.0 4.0 - 801.0 4.0 - 801.0 A-a(T) 11.3 mmllg 1.0 - 800.0 0.0 - 801.0 0.0 - 801.0 a/A(1) 93.1 % 0.0 - 100.0 -1.0 - 101.0 -1.0 - 101.0 Patient Test Info Sample Equipment 1. Respiratory Settings Records (4 of 5) Page 1 of 1 Link status . Wi-Fi Link listening on 192.168.56.1:13255 Bluetooth listening on 60:F6:77:6B:93:A5 Note: Test results are displayed in the same format, with the same units and ranges, as received from the epoc Host Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 2 of 4 Job Aid | eDM Lite Operating The Software Effective Date: 24-JUL-2019 | HOOD05162003023876 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 3 of 4 Job Aid | eDM Lite Operating The Software Effective Date: 24-JUL-2019 | HOOD05162003023876 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 4 of 4
- epoc
- eDM
- Lite
- Enterprise
- Data
- Manager