eSie Left Heart™ Measure Package 5.1 software release - USA
This online course (OLC) will help the clinician, sonographer, radiographer, nurse, or student understand eSie Left Heart™ Measure Package workflow featuring ejection fraction for both the left ventricle as well as left atrium, utilizing the “one click” method.
uccessful completion of this training is eligible for American Society of Radiology Technician (ASRT) Category A continuing education units (CEU).
Congratulations! You have completed the eSie Left Heart™ Measure Package course. This course covered the use of the eSie Left Heart package with for both EF and ES/ED Volumes for both the LV and LA. Listed below are the key points presented in this course. Take time to review the material. Download Course Review: In this course you have learned to: Comprehend how to activate the eSie Left Heart™ Measure Package for quick ejection fraction and volume data for both the left ventricle as well as left atrium. Identify the technology behind this feature. Gained expertise to implement Edit when needed. Upon completion of this course, the learner will be able to: Comprehend how to activate the eSie Left Heart™ Measure Package for quick ejection fraction, and volume data for both the left ventricle as well as left atrium Identify the technology behind this feature Implement Edit when needed Within this section we will review eSie Left Heart™ (LH) Measure Package for LH ejection fraction (EF), end diastolic (ED) volume (EDV) and end systolic (ES) volume (ESV) for both the left ventricle (LV) as well as the left atrium (LA). We will briefly review some of the technology that drives the “one click” results. It has been noted that there can be a wide range of user measurement variability and results, within an imaging department. Many different methods of measurements can be employed; such as measuring leading edge to leading edge, mid edge to mid edge, and other techniques. Using an Artificial Intelligence powered algorithm, (AI-Powered) eSie Left Heart package can standardize measurement results. Technology Technology behind eSie Measure Package Tab TitleTextMeasurements Available With the use of the eSie Left Heart package quick and accurate Left Heart measurements are available for both Adult Echo and Pediatric Echo packages. eSie Left Heart package is available for Adult transthoracic echocardiogram (TTE), Pediatric echocardiogram and transesophageal echocardiogram (TEE) applications. The eSie LH package can be used on both apical 4 chamber (4CH) as well as apical 2 chamber (2CH) views to derive bi-plane results. Currently the calculations obtained: For the LV: EF, EDV, ESV For the LA: EF, EDV, ESV Benefits The use of eSie Left Heart package can bring many benefits to the department. Some of these are: Standardizing measurement results and reproducibility Streamlining workflow by reducing users interaction time with the images Lowers measurement variability and simplifies complicated tasks eSie Access™ Measurement Interface The “one click” calculation list is displayed utilizing eSie Access™ interface. The eSie Access interface presents the user with the correct measurement list as per mode in use. This allows the “single click” measurement method. The eSie Access also displays the calculation list on the right side of the screen to show measurements made, as well in the results box on the image. If any of the measurements or caliper points are edited, re-positioned or deleted; the results will be updated and instantaneously displayed in the calculation list to show the new results. Tip: To standardize measurements within a department, it is suggested to resist moving the caliper points or tracings unless they are obviously placed incorrectly. Misplaced calipers or tracings can occur when sub-optimal images are measured and there is not enough pixel information for automatic placement. The configuration around the trackball provides an ergonomic design. The Controls and Soft Keys conveniently placed around the trackball are referred to as the home position. Working in the home position minimizes hand movements and reaching, allowing the user to quickly navigate through each task. This same configuration of trackball, Controls and Soft Keys located on the control panel are mirrored as icons on the bottom of the image. The user can either activate the appropriate Control or Soft Key on the control panel; or use the active pointer and trackball to choose the associated icons on the bottom of the image by pointing to the icon with the active arrow and pressing the Select control. Letting the user choose the method of measuring, allows a freedom of using the workflow best suited for that user. Home-base Review of Home base Conrols Instructions:Flash File:HTML5 File:/content/generator/Course_90022330/trackball_exp2019_2/index.htmlPDF File: Soft Keys Review the Soft Key Controls Instructions:Flash File:HTML5 File:/content/generator/Course_90022330/2019_SoftKeys_V2a/index.htmlPDF File: Now that you have a sense of how the Controls and Soft Keys around the trackball work, we will begin with activating the eSie Left Heart package. We will review the workflow. 2D Imaging – Apical 4CH View Press Freeze (if image is not already frozen). Press ED Soft Key The image will transition to the optimal end diastolic phase of the heart cycle. Using the eSie Access™ measurement interface Press the Next control or right click. This will activate a drop-down Measurement Menu. Using the active arrow, point to the eSie Left Heart label. Press Select to choose this eSie Left Heart package. The Left Heart measurements are performed automatically. The calculation list will be displayed on the right side of the screen to show measurements made and also displayed on the image. For easy identification, the LV results are displayed in white and the LA results are displayed in yellow. The tracing is still active and the user can use the active arrow to move into the ED or ES image to edit the tracing if needed. As the active arrow approaches the trace line to be edited, the line will change to red in color. The further away from the trace line, the larger the area can be edited. Inversely, the closer the arrow is positioned to the red trace line the smaller the area is to be edited. Once the user chooses the optimal amount of tracing to be edited, press the Select control. Use the trackball to reposition red highlighted trace area, Press Select to set trace. After all edits are competed press Select control again to complete measurements and send to the report. Process can be repeated for the apical 2CH position LH Example Example of eSie Left Heart Package Instructions:Flash File:HTML5 File:/content/generator/Course_90022330/ESIE LH.mp4PDF File: Explore the links below for the Glossary, References, and Further Reading opportunities. Glossary Glossary ED – End Diastole ES – End Systole EDV – End Diastolic Volume ESV – End Systolic Volume ED/ES – End Diastolic/End Systolic LH – Left Heart LV – Left Ventricle LA – Left Atrium 4CH – Apical 4 Chamber View 2CH – Apical 2 Chamber View TTE – Transthoracic Echocardiogram TEE – Transesophageal Echocardiogram AI Powered – Artificial Intelligence powered algorithm References References Roee S Lazebnik, MD.Ph.D, Siemens Medical Solutions, USA, Inc., Ultrasound, Mountain View CA USA, Knowledge - based Workflow 2008 S. Michelle Bierig, MPH, RDCS, FASE, Donna Ehler, BS, RDCS, FASE, Margaret L. Knoll, RDCS, FASE, Alan D. Waggoner, MHS, RDCS; STANDARDS FOR THE CARDIAC SONOGRAPHER: A Position Paper – ASE Guidelines JASE 2009 Donna Ehler, BS, RDCS, Dennis K. Carney, RCVT, Ann L. Dempsey, MEd, RDCS, Rick Rigling BS, RDCS, Carol Kraft, BS, RDCS, Sandra A. Witt, RDCS, Thomas R. Kimball, MD, Eric J. Sisk, BA, RDCS, Edward A. Geiser, MD, Cris D. Gresser, RN, RDCS, and Alan Waggoner, MHS, RDMS, Guidelines for Cardiac Sonographer Education: Recommendations of the American Society of Echocardiography Sonographer Training and Education Committee The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases. Certain products, product related claims or functionalities described in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. eSie Left Heart™ Measure Package and eSie Access™ is a trademark of Siemens Medical Solutions USA, Inc. ACUSON SC2000™ SC2000 PRIME ultrasound system is a trademark of Siemens Medical Solutions USA, Inc. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Welcome to the Siemens Healthineers eSie Left Heart™ Measure Package with 5.1 software release. This online course will review the process for utilizing eSie Left Heart package for an automated and accurate ejection fraction. During the course, there is a lot of detailed information. Look for links and interactions located on the bottom of pages that provide more information. To successfully complete this course, please view all available content. We hope you enjoy our course. Click on the arrow at the bottom right of each page to continue. Navigation Instructions Navigation Instructions Instructions:Flash File:HTML5 File:/content/generator/Course_90022330/Navigation_Instructions_LH_Final_a/index.htmlPDF File:
- ASRT
- CME
- CEUU
- eSie Measure
- eSie Measurement
- Measurement
- Easy Measurement
- 2D Measurement
- Measurement Tools
- EF measurements
- ejection fraction
- LA ejection
- LV EF
- Acceleration Package
- 2D Measure
- SC2000
- AI
- Artificial Intelligence Powered