EVAR Guidance Job Aid
Job Aid EVAR Guidance Options to Perform EVAR Guidance • CTA data set from PACS, Disc, or USB • Perform a DynaCT with Contrast 1. Open Patient Search and import correct patient from PACS 2. Load CTA or DynaCT into the Active C-Arm folder within the 4D tab Examination Patient Review Patient 3. Select EVAR Guidance from 4D workflow . EVAR Guidance Automatic segmentation and centerline of Aorta, Renals, and Iliacs is performed 4. Create Vessel Tree Celiac, SMA, IMA, etc. Identify vessels manually; a distal single click is needed on any MPR EVAR Guidance Creato Vessel Tres Define Landmarks Check position and angulation of the existing landmarks Add or eo t landmarks. if necessary 5. Define Landmarks Default Landmarks: Ostium of Left renal artery, Ostium of Right Renal Artery, Infrarenal Landing Zone Show Landmark L Remal Additional Landmarks: R Renal Landing Zones, Additional ostia can be defined O You can check the C-arm angulations for the ostia/landing zone pairs + F Centerline F Surface + Overlay SIEMENS Unrestricted siemens.com/healthineers Healthineers Job Aid | EVAR Guidance Effective Date: 03/17/2018 | Quality HOOD05162002847320 NOTE: You can save new angles for projections under Define Landmarks Tab Toggle through all Landmarks to see Ostia and to make adjustments as needed All manipulations and markings can be done Tableside using the Heads up Display (HUD) 6. Overlay Tab (Move C-Arm into area of interest prior to selecting Overlay Tab) Perform 2D3D Registration or 3D3D Registration Select 3D Roadmap to overlay the Live image on the 4D Monitor Select Overlay 3D Objects on Live to see selected 3D objects on the live screen Show the segmented wall as Contour or Wireframe or hide vessel wall Live Unrestricted Siemens Healthineers Services Page 2 of 3 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual” issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality” may not (yet be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2017
- EVAR Guidance
- Hybrid OR