Export Protocol Workflow
Export Protocol Workflow
Export Protocols Workflow Note: When exporting protocols the system will be blocked during this time. It is recommended to start a protocol export only when no scans or other applications are running. 1. Export protocols 1 Exam Explorer - WUSERthe Load CD/DVD in drive (or) insert flash drive Object Edit Tools Insert Open Exam Explorer Open Ctrl+O Select > User Tree New .... Ctrl+N Select>Object>Export Save Ctrl+S Pop-up message appears > Select > OK Save AS .... X Print ... Ctrl+P Exam Explorer Export Export Import You are about to export protocols to a storage media. Exit This action may take several minutes. Please be aware, that the system will be blocked during this task. We recommend to start a protocol export only when no scans or other applications are running. Do you want to export now? OK Cance 2. Export Object box opens Drives drop-down o Select > U Drive when using a CD/DVD (or) o Select > F or G Drive when using a flash drive Select > Export Export Object X File Name: Folder head c: \medcom\user @ Medcom user File Type: Drives Exam Database (* . edx) c: Med_System Export sequences a: c: Med System f: MR g: NANO PRO Export Cancel i: Med IPT t: Med_System u: Med_System SIEMENS www.usa.siemens.com/healthcare 497 Effective Date: 09/09/2016 Page 1 of 2 3. Flash Drive >edx file of protocol is available & saved 4. CD/DVD Open > Patient Browser Select > Transfer > Local Job Status Patient Browser Patient Applications Transfer Edit View Filter _valuation Sort Op Import Ctrl+1 Archive to DVD-RW Archive to. Send to ... Local Database Export to. Scheduler Eject from DVD-RW HIS/RIS Eject from .. DVD-ROM Finalize Medium and Eject from DVD-RW DVD-RW Local Job Status ... Ctrl + L Network Job Status ... Ctrl+N Import from Off-line. Export to Off-line Record Off-line Files Delete everything in Local Job Status Select > Close Local Job Status X Status Patient Object | No. of Images Source Destination Posted Remain Failed Objects Co EP Enti 164 DV Local 13:5 O Co ... pt2 Enti ... 119 DV ... Local 13:5. Co ... Imag ... 358 C .... Local 11:5. 00 Stop Restart Continue Delete CD or DVD Progress Clear Close Help Select > Transfer > Record Offline Files CD/DVD drive will open when finished writing to CD/DVD Transfer Edit View Filter Evaluation Sort Op1 Import Ctrl+ Archive to DVD-RW Archive to ... Send to .. Export to Eject from DVD-RW Eject from ... Finalize Medium and Eject from DVD-RW Local Job Status ... Ctrl+L Network Job Status. Ctrl+N Import from Off-line .. Export to Off-line .. Record Off-line Files SIEMENS www.usa.siemens.com/healthcare Page 2 of 2
- MAGNETOM Aera
- MAGNETOM Avanto
- MAGNETOM Espree
- MAGNETOM ESSENZA
- MAGNETOM Skyra
- MAGNETOM Symphony
- a Tim System (SaTs)
- MAGNETOM Trio
- a Tim System (TaTS)
- MAGNETOM Verio
- MAGNETOM Symphony