Extracting an Energy Group from a Multi Energy Series
Extracting an Energy Group from a Multi Energy Series All Symbia Systems Description: This step by step document will assist the user in extracting a single energy group from a series that was acquired with multiple energies. 1. On the Command Module Patient Browser, click the Series icon to display the browser as Series. 2. Highlight the multiple energy series that you are wishing to extract from. 3. Launch the Series Arithmetic workflow. 4. Select the Settings tab in the Series Arithmetic workflow and uncheck the “Use Entire Series” checkboxes. Series Arithmetic View Template Workflow Activities Help C A Data Selector Settings |Arithmetic Series Configuration Input Type Output Type Series 1st Series ANY Use Entire Series ANY Arithmetic v 2nd Series: ANY Use Entire Series ANY 5. Go back the the Arithmetic tab SIEMENS siemens.com/healthineers Healthineers . Extracting an Energy Group from a Multi Energy Series Effective Date: 01/18/2018 | Quality HOOD05162002757638 6. Working on the top row (Operand 1), select the energy group you would like to extract by using the pull down menu. 100 0 Ph:1 Fr.1 1355cts 0sec Ph:1 Fr2 1046cts 1 sec Ph:1 Fr:3 682cts 2se Duration:1 sec 64x64 Duration:1 sec 64x64 Duration:1 sec 64x6 Poc7.8mm 99m Poc7.8mm 99m Poc7.8mm 99m Tochnotium Tochnotium Energy Group A Select Series: 7. Go to the second row (Operand 2) and select the series you are working with from the pull down menu “Select Series”. Select Series: 8. Select the “All Frames and all Detectors” for Operand 2. 100 0 Ph:1 Fr.1 1355cts 0sec Ph:1 Fr.2 1046cts 1 sec Ph:1 Fr:3 682cts 2se Duration:1 sec 64x64 Duration:1 sec 64x64 Duration:1 sec 64x6 Poc7.8mm 99m Poc7.8mm 99m Poc7.8mm 99m Tochnotium Tochnotium Technotium COD 2 All Frames Select Series: 9. Click the Extract tool in the toolbar 10. The result series will be shown in the 3rd row. 11. Complete the workflow and refresh the patient browser. 12. You will have another series with the extention “arithmetic”. This is the extracted energy group. Siemens Healthineers Services Page 2 of 3 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instruc- tions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety infor- mation like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018
- Extracting an Energy Group from a Multi Energy Series