PEPconnect

FLC: Creating A Quality Control Exam and Log

This Step by Step will guide the Users in setting up a Quality Control Exam and
log.

FLC: Creating A Quality Control Exam and Log XPRF 1. Click on the Icon “Quality Control Study” under the “Service” sub tab. Patient Settings Service ALO 2. When the Pop-Up box appears, click on “OK”, the password field should be left blank, unless a customer specific password was created. Password OK Cancel Change Password SIEMENS siemens.com/healthineers Healthineers Job Aid | Quality Control Exam Log Effective Date: 11/29/2018 | Quality HOOD05162002976785 3. The “Quality Control Log” will open. Select the “Examination” Tab on the right. Quality Control Study QualityControl, QualityC .. 30-10-2014 Deviation index | Clinical EXI |Maximum EXI | Minimum EXI | Physical EXI KV mas SID Cufilter Collimation Patient 0 Examination Patient Settings |Service Postprocessing Documentation 0.012008 PEREF 4. Choose the desired OGP View and make the exposures. The exposures will be logged on the Quality Control Study screen. o T = Table o W = Wall QUALITY CONTROL Patient -D Q03T Automatic Exposure 70kV Q03W Automatic Exposure 70kV Examination QualityControl, QualityControl # 655.4 cm x 655.4 cm 30-10-2014 Current Target Postprocessing none KV 52 MAS 2.5 Documentation ms Dose mm Cu 0.0 Focus % 80 Siemens Healthineers Services Page 2 of 3 © Siemens Healthcare GmbH, 2017 Disclaimers*: Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2017