FLC: Deleting Images from the Documentation Tab
FLC: Deleting Images from the Documentation Tab step by step
FLC: Deleting Images from the Documentation Tab Radiography 1. While in the Documentation Tab, click the Select subtask card. Select Film Send LIO 2. On the bottom left of the Select subtask card, left-mouse click the shred icon. 3. User message “Please select images to delete” will appear. EX User Message Please select images to delete OK Cancel SIEMENS siemens.com/healthineers Healthineers Job Aid | FLC: Deleting Images from the Documentation Tab Effective Date: 06/02/2017 | Quality HOOD05162002609386 4. Left-click on the imageor images to be 3 deleted. An X will appear over the image/images selected. Click OK. RAD 5. If reject analysis is active, a message will Reason for image rejection appear. From the drop down, select the Patient Name: YSIO MAX [XR Elbow AP/LAT Left] “Reason” for deleting. If applicable select Please select the reason for rejecting the images Please enter a user identification. User, and then click OK. Note: Only general x-ray images will request Reason Artifact(s) other than grid artifacts User a Reason and a User for reject analysis. Siemens When deleting fluoro images the Reason for OK Cancel image rejection box will not display. 6. The image or images are now removed from the documentation tab. Note: If the images were not sent to PACs and the Recycle Bin is active the deleted images will move to the Recycle Bin. Siemens Healthineers Services Page 2 of 3 © Siemens Healthcare GmbH, 2017 Job Aid | FLC: Deleting Images from the Documentation Tab Effective Date: 06/02/2017 | Quality HOOD05162002609386 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the lates t version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3 © Siemens Healthcare GmbH, 2017
- FLC Deleting Images from the Documentation Tab