FLC: Programming a Stand Position

FLC: Programming a Stand Position

FLC: Programming a Stand Position XPRF 1. Create a new patient exam and select the OGP that requires the new “Stand Position”. Note: This exam will be used for testing purposes. 2. Set up the system as if performing the exam. Ensure the tube, detector, SID, detents and cen- tering are all in the correct position. 3. On the FLC , select the “Settings” subtask card. Select the “PEX Editor” icon and login. Patient Settings Service EXI 4. Select the “Param Module” tab at the top. The “Stand Position” section is noted below. Exam Organ Program Fluoro Program Param. Module Configuration Body Part Examined Stand Position ABDOMEN dentifier Name Collimator settings Ignore for auto-cropping Position: Delete Store New EXI Values Store Position Store Parameters Identifier Delete Activate New Name Spatial Frequency Parameters Min. EXI Max. EXI Target EXI Identifier Delete Store New Name New Position Diamond View ID 00 Gradation Parameters Diamond View Name Off Noise Reduction Identifie Edge Filter: Kernel Name Edge Filter: Gain Shape 1 y Harmonization: Kernel 31 Contrast 0.1 Harmonization: Gain Center Offset 2048 Delete Store New Delete Store New SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 07/8/2020 | HOOD05162003107061 Healthineers Job Aid | Programing a Stand Position Effective Date: 07/08/2020 | HOOD05162003107061 5. Click on the “Identifier” drop down and find a “c” number that is not in use. In this example c012 is utilized. Enter the number in the “Identifier” field (c012) and a stand position name in the “Name” field. Stand Position Identifier Name 008 Collimator settings c009 mppping Position c010 c011 c329 Store Position d001 d002 frameters Delete d003 Attivate New 6. Click on the “New” Icon. Stand Position Identifier c012 Name new position Collimator settings Ignore for auto-cropping Position: Undefined Store Position Store Parameters Delete Activate New 7. Click on “Store Parameters” and then “Store Position”. Stand Position Identifier c012 Name new position Collimator settings Ignore for auto-cropping Position: Undefined Store Position Store Parameters Delete Activate New SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 05/XX/2020 | HOOD0516200309 Healthineers Page 2 of 4 Job Aid | Programing a Stand Position Effective Date: 07/08/2020 | HOOD05162003107061 8. Click on the “Exam” tab and select the “OGP View” requiring the new “Stand Position”. Double click to access the “OGP Program” tab. 9. In the “Stand Position” box, select the newly created stand position from the drop down. Up- date the “OGP” by selecting “Store”. Exam Organ Program Fluoro Program Param. Module Configuration Body Part Examined ANKLE Alternative Acquisition Programs Program Name T ANKLE Right 4-12yrs (d) X ANKLE Right 4-12yrs. Acquisition Mode DR RAD Acquisition Type Table X - Ray Parameters Image Processing Parameters Presettings Mark Image Auto-cropping Standard Set Black Fluoro Program Set CP_RAD_Po .. PT Position Not defined Defined size as cropped MField Laterality Not Defined Amplification 2.0 V Auto View position Not Defined 1 pt Gradation Parameters Anatomically Correct View 1 pt with ext. exp. 4 Extremity/Skull Flip No change )2 pt 3 pt Invert (Image) RA 3 pt with AEC Spatial Frequency Parameters OOO KV 52 Rotate 90 180 270 MAS 2.2 v Extremities - HC Labe ms EXI Values R Exp. Correction EP default Dose 2.5 Sensitivity 400 Windowing Tube Load 80 Width Factor Stand Parameters % Focus Center Shift V Auto TOD not defined cm Filter Type 0.0 Window Center 2000+ Grid No value cm Grid rotation Cu mr Window Width 2500+ Collimator 7.48 × 5.12 = inches Stand Position new position Top Alignment SID Tracking Tracking Anatomic order number 0 Store Store as new Print Delete previous lext 10. Use the patient set up in step 1 to verify the system moves to the correct position. SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 05/XX/2020 | HOOD0516200309 Healthineers Page 3 of 4 Job Aid | Programing a Stand Position Effective Date: 07/08/2020 | HOOD05162003107061 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 05/XX/2020 | HOOD0516200309 Healthineers Page 4 of 4