Fluorospot Compact: Sending Exam Protocol to PACs
Fluorospot Compact: Sending Exam Protocol to PACs step by step
FLC: Sending the Exam Protocol to PACS XPRF Select Fim Send mination Target 1 DACSTORE Target 2 Target 3 1. Select the “Documentation” tab, and navigate to the Send Exam Protocol as: stprocessing “Send” subtask card. SCimage DICOM Dose SR Override configured settings ? Documentation Select Film Send Target 1 DACSTORE Target 2 2. Select the option for “SC Image” (1), as in figure (A). Target 3 3. Prior to sending, ensure all desired images are “marked” and select the “DICOM Send” icon (2). a. Once sent, the patient’s “Exam Protocol” will Send Exam Protocol as: cross over to the default PACS destination along with the selected images. (1) SC image b. The “Exam Protocol” (dose report) will appear as DICOM Dose SR an additional thumbnail in PACS as the last image in the case. Override configured settings (2) Fig. A SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 05/04/2020 | HOOD05162003090145 Healthineers Job Aid | Sending the Exam Protocol to PACS Effective Date: 05/04/2020 | HOOD05162003090145 Note: To send the “Exam Protocol” to an additional or alternate PACS target, utilize the following steps and Figure B. o Select the box for “Override Configured Settings” within the “Send” subtab (1). o Utilize the “Target 1, 2 or 3” to select the desired destination (2). o Select the “DICOM Send” icon (3) to send the protocol to the new/additional targets. o Ensure the images are “unmarked” if only sending the “Exam Protocol” to the additional “Target”. Select Film Send Target 1 store Target 2 syngo_Workplace 12 Workplace 2 Target 3 Send Exam Protocol as: SC image DICOM Dose SR (1) Override configured settings (3) Fig. B SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 05/04/2020 | HOOD05162003090145 Healthineers Page 2 of 3 Job Aid | Sending the Exam Protocol to PACS Effective Date: 05/04/2020 | HOOD05162003090145 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and c autions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be comme rcially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 05/04/2020 | HOOD05162003090145 Healthineers Page 3 of 3
- Ysio
- flc