Function Comparison: syngo Dynamics Workplace (VA20) vs Portal
This job aid compares and contrasts the general functions and features of syngo Dynamics VA20 Workplace and the Remote Access Portal.
Functionality Comparison (VA20): syngo Dyanmics Workplace vs. Portal Function/Feature syngo Dynamics syngo Dynamics syngo Dynamics Workplace Portal Portal Comments Configuration Tool: Layout (Auto-hide Toolbar), Autoplay, Color Scheme, Image Process, X N/A and Export Studies drive Log In & select Department; Logging In/Out X X must Log Out or license will stay in use; Use Remote Access Privilege AD LDAP X X Change Password X X Disabled when user is AD LDAP Integrated Unlimited Concurrent Users; Image View Only X X Browser must support Silverlight NPAPI Windows 7 or 10 using Image and Reporting X X Internet Explorer, ActiveX and JavaScript Enabled API Integration X X Study List Menu: Patient, Study, Utili- ties, Print, and Help X N/A Access to User Manual X X syngo Dynamics Portal User Manual; Login Page; Study List Access to Release Notes X X Login Page; Study List Access to Measurements and Calculations Manual X N/A Report & Worksheet Icon X X Department/Server Identified X X Studies From: Enterprise (Deparments/Servers) X X Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/08/2020 | HOOD05162003101228 Healthineers Job Aid | syngo Dyanmics VA20 Workplace vs. Portal Effective Date: 07/08/2020 | HOOD05162003101228 Function/Feature syngo Dynamics syngo Dynamics syngo Dynamics Workplace Portal Portal Comments Local Cache X N/A Selectable Compression X N/A Site ID X X Quick Search (Name starts with… or Patient X X ID is…) Search Field contain: Patient Field Search X X Name, Patient ID, Patient Birth Date, Study Type, Study Date, and Modality Sorting Study List X X Studies in List: # - Scroll Through Study List X N/A Shows pages; Paging buttons utilized rather than scroll bars Selected: # X N/A Study List Columns: Lock Icon, PDF, Patient Name, Patient ID, DOB, Acc#, Study Type, Modality, Study Date, # of Images, Study Location, Prior Studies, Study Status, Reports, Study List Fields X X Indication, Diagnosis, Technologist, Referring Physician, Custom1, Custom2, Report Upload Status, Study Performed Location, Server Name, Department Name, Master Patient ID Adjust Field Length X X Adjust Field Location X X Copy Studies to… X N/A Assign Studies to… X N/A Create New Study X N/A Delete Study X N/A Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/08/2020 | HOOD05162003101228 Healthineers Page 2 of 7 Job Aid | syngo Dyanmics VA20 Workplace vs. Portal Effective Date: 07/08/2020 | HOOD05162003101228 Function/Feature syngo Dynamics syngo Dynamics syngo Dynamics Workplace Portal Portal Comments HL7 Reconciliation Tool X N/A Reviewing Study Images Menu (Patient, Study, Utilities, Images, Print, and X N/A Help) Open Study w/ Double-Click X X Layout X X Full; Max; 2:1; 3:1; 4:1; 6:1; 9:1; 12:1 Drag and drop image to Rearrange Images N/A X desired location, Thumbnails on Workstation Full Screen X X Displays full screen of syngo Dynamics Portal Select Study; Click Report &/or Worksheet X X Separate IE window displays Report & Worksheet Study List Folder X X Return to main Study List Workplace: Generic measurements only if study in Tools X X DEFAULT department. In syngo Dynamics Portal only Generic Measurement tools are available Automatic transfer of Manual entry of measurements to X N/A measurements into field on worksheet worksheet Cardiac Quantification X N/A Vascular Quantification X N/A Original Quality Viewer N/A X Separate IE window displays OQV for selected image Edge Enhancement X N/A DSA Images X X Cannot remove the DSA Mask in portal Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/08/2020 | HOOD05162003101228 Healthineers Page 3 of 7 Job Aid | syngo Dyanmics VA20 Workplace vs. Portal Effective Date: 07/08/2020 | HOOD05162003101228 Function/Feature syngo Dynamics syngo Dynamics syngo Dynamics Workplace Portal Portal Comments Playback Controls X X Priors Folder X X Includes Local dept and Enterprise Image to Report X X All Images X X All Series X X US Studies Only Key Images X X Key images must have been defined on workplace initially Workplace using Page Up or Down arrows will scroll to the Page Up Arrows X X next set of images. In syngo Dynamics Portal it is used to display the next set of images in the layout grid Page Down Arrows X X Used to display images in layout grid Clear Images X X Removes all images from layout grid Delete Image X N/A Print Images to DICOM Printer X N/A Invia Corridor 4DM Integration X N/A Third-Party Application Launchers X N/A Reporting Modify Study Privilege (concurrent license) Study is in DEFAULT Study in DEFAULT department: Reporting Department X N/A unavailable displays; study must be moved to existing department Study In-progress X X Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/08/2020 | HOOD05162003101228 Healthineers Page 4 of 7 Job Aid | syngo Dyanmics VA20 Workplace vs. Portal Effective Date: 07/08/2020 | HOOD05162003101228 Function/Feature syngo Dynamics syngo Dynamics syngo Dynamics Workplace Portal Portal Comments Collaboative Mode X X Take Control X N/A Cath Reporting and Signoff X X Hemo Data must be imported at workplace first Sensis Interface X X Study must be closed for data updates Verify Button X X Report, Close and Worksheet N/A X Separate IE window display Report & Worksheet Save Button N/A X Clicking X to exit will also save study data In syngo Dynamics Portal there Priors Folder X X is a Separate IE window to display Report & Worksheet Automatic Enhanced Discrete Date Export X X Configurable batch export Manual Enhanced Discrete Data Export X N/A Automatic Billing Export X X Nightly batch export Carry Forward X X Decision Support Rules Engine X X Department Name Name of department is Identified X X displayed when reporting evoked Resolve Name/ID Conflict X X Import Third Party Data (Hemodynamics, EP or X N/A Measurements) Coronary Tree Diagrams X X Mark Current Report As Completed X X Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/08/2020 | HOOD05162003101228 Healthineers Page 5 of 7 Job Aid | syngo Dyanmics VA20 Workplace vs. Portal Effective Date: 07/08/2020 | HOOD05162003101228 Function/Feature syngo Dynamics syngo Dynamics syngo Dynamics Workplace Portal Portal Comments Mark Current Report As Verified X X Manually Marking a Study as Read X N/A Manually Marking a Study as Unread X N/A Delete Report X X Clone Report X X Add Report X X Print Preview X X Sent to X X View Data X X Set All Normal X X Print X X Viewing the Fax Log X N/A Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/08/2020 | HOOD05162003101228 Healthineers Page 6 of 7 Job Aid | syngo Dyanmics VA20 Workplace vs. Portal Effective Date: 07/08/2020 | HOOD05162003101228 Please note that the learning material is for training purposes only! For the proper use of the software, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 …………………………………………………………………………………………………………………………………………………………………… Siemens Healthineers Headquarters Siemens Medical Solutions USA, Inc. Siemens Healthcare GmbH 40 Liberty Boulevard Henkestr. 127 Malvern, PA, 19355, USA 91052 Erlangen, Germany Phone: Telephone: +49 9131 84-0 +1-610-448-4500 / +1-888-826-9702 Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/08/2020 | HOOD05162003101228 Healthineers Page 7 of 7
- syngo dynamics
- va20
- workplace
- portal
- remote access