PEPconnect

General Laboratory: Blood Gas: Sample Collection and Proper Handling: Capillary Sample Draw

Instructional video about how to collect a capillary blood gas sample.

Blood gas sample collection and proper handling. This is an instructional video about how to collect a capillary blood gas sample. Follow your local hospital procedures to prepare the patient, an collection site for obtaining the blood sample, collecting arterial ized capillary blood may be an alternative to arterial blood collection, particularly in infants. The most typical site for capillary collection in infants is the lateral or medial plantar surface of the heel. However, the tip of the big toe, fingers and earlobe may also be used. Blood gas analysis is performed to test vitals in critically ill patients. Blood gas analysis gives information on gases and may also include electrolytes, metabolites, total hemoglobin, Co, oximetry, and neonatal bilirubin. In theory, blood gas values obtained from a capillary draw approximate arterial values. However, typically the PO2 values obtained with capillary samples may be lower. Please ensure you have all the materials you need to draw a patient sample. This includes a capillary tube, the capillary caps, a Lancet, an alcohol wipe, gauze and bandage. The capillary used for blood gas analysis should include dry electrolyte balanced lithium heparin as the preferred anticoagulant before performing the capillary draw, confirm the patient's identity. To Arty realized the puncture site, warm the skin to a temperature of approximately 42 degrees Celsius. Clean the puncture site. Do not use a skin cleaning wipe that contains quarternary ammonium substance, such as benzalkonium as it may affect the electrolyte parameters reported, particularly sodium. Let it dry. Puncture the skin with a disposable Lancet to a depth no greater than 2.0 millimeters. Wipe away the first droplet of blood. Place the tip of the capillary sampling device in the center of the blood droplet and allow to fill the capillary as rapidly as possible without air bubbles. Fill the capillary tube completely with blood that contains no air bubbles. Seal both ends of the capillary with the Cavaleri caps. Apply pressure to the collection site and bandaged the heel. Makes the sample thoroughly by rotating your wrist back and forth for a minimum of 20 seconds. This helps to dissolve the heparin and minimize clot formation in the capillary. Label the capillary with the patient ID and immediately transport the capillary to a Siemens healthineers blood gas system. Follow a two step mixing process first by rotating your wrist back and forth and then rolling the capillary between your fingers about 10 times. Remove the caps from the capillary. Do not expel any blood on to a gauze pad to ensure sufficient sample volume for analysis. Present the capillary sample to the analyzer and start analysis. Recognize that a sample containing blood clots should not be used on the blood gas analyzer because it can affect not only the accuracy of the patient results but also negatively impact the operation of the blood gas analyzer. The patient's blood gas results will be ready within 60 seconds. According to the CSI guidelines, blood gas testing should be completed within 10 minutes and not longer than 30 minutes after drawing the sample. Remove the capillary from the analyzer and discard the capillary according to hospital guidelines. Proper sample handling, mixing and time to analysis helps to ensure accurate patient results.

air bubbles,wrist back,collection site,alcohol wipe,role capillary,analysis helps,blood sample,capillary caps,capillary blood,blood,sample,patient,capillary,gauze,heparin,total hemoglobin,neonatal bilirubin,hereinafter collectively,future availability,proper handling,patient id,operator manual,specific country,collection,caps,training,benzalkonium,latex,country,remove

MOIST TOWELETTE Seal both ends of the Capillary ,déride Remove Remove caps Gas Capillary blood LATEX Capillary caps capillary with caps Total hemoglobin Capillary Patient ID premoiste Role capillary Cleansing To Single use Only Lancet Gases CO-oximetry Alcohol wipe 55 Sample Collection collection For the proper use Of the software, please always us the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual) SIEMENS Follow your local hospital procedures Proper sample handling, mixing 55 25 issued by Siemens Healtineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Gauze WARNING: Clots can affect the Any material used in this training wi I not be updated on a regular basis and does not necessarily reflect the latest version Of the software 60 -45 15- Blood Gas Analysis and hardware available at the time Of the training. No quaternary MOIST to prepare the patient and collection site and time to analysis helps to ensure Hd Bandage pH accuracy of the test results and 15- TOWELETTE TO TO ETTE ETTE The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Healthineers ammonium substances and Proper Handling -déride Sdéride the fluidics of the instrument. Ben Benzalkonium Chloride , doride Cleansing To for obtaining the blood sample. accurate patient results. Note: Some functions in this material are optional and might not be part Of your system. 40 25 20 Dry, LATEX FREE LATEX such as benzalkonium 20 Certain products, product related claims or functionalities (hereinafter collectively "Functionality") many not (yet) be commercially available @ Siemens Healthcare Diagnostics Inc., 2020 SIEMENS premoiste Neonatal bilirubin Healthineers in your country. Due to regulatory requirements, the future availability Of said Functionalities in any specific country is not guaranteed. in your country. Due to regulatory requ•rements, the future availability Of said Functionalities in any specific country is not guaranteed. Cleansing Toweletter Cleansing To Od electrolyte-balanced Capillary blood Single use Only Please contact your local Siemens Healthineers sales representative for the most current information. RAPIDLab, RAPIDPoint and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., Mix sample in 2 seconds seconds 60 seconds heparin Electrbolytes The reproduction, transmission or distribution Of this training or its contents is not permitted without express written authority. SIEMENS collection or its affiliates. Capillary Sample Blood Draw Capillary SIEMENS Offenders will be liable for damages. Healthineers Role capillary seconds figure 8 motion Healthineers Mlectabolites Do not "milk" All names, data Of patients, parameters and configurations dependent designations are fictional and examples only. Product availability may vary from country to country and is subject to varying regulatory requirements. Roll capillary Clean site Depth not greater Please contact your local representative for availability. All rights, including rights created by patent grant or registration Of a utility model or design are reserved. the collection site between fingers than 2 mm Copyright @ Siemens Healthcare GmbH 2020 10 minutes