How to Configure and Use CARE kV
How to Configure and Use CARE kV step by step
How to Configure and Use CARE RV Computed Tomography Adapting the kV value for each patient offers significant dose reduction potential; however, configuring CT technical parameters on the fly can be complex and time consuming. Siemens' CARE KV automatically suggests a kV setting for each individual patient, specific to their size and the type of examination being performed, in order to optimize both dose and image quality. This value is applied to the entire scan range and does not modulate during the scan. There are three different modes for CARE KV: Off, On, and Semi, and these can be found on the Scan subtask card. CARE Dose4D |CARE KV On Slice 5.0 mm - Acq. 128 x 0.6 mm Off Pitch 0.6 Semi Eff. mAs KV On Direction Craniocaudal Organ characteristic: Abdomen CTDIvol (32cm): mGy DLP: mGy*cm Scan time 5.15 $ 2: Scan start Start button Rotation time 0.5 s ] Delay Language German API None Routine Scan Recon Auto Tasking 1. CARE KV - Off With CARE KV turned Off, the kV is not adapted to the patient and CARE Dose4D functions to modulate the mAs as usual. The system will use the kV value that has been manually entered into the protocol. CARE Dose4D M CARE KV Off Quality ref. mAs 210| Ref. KV Dose saving optimized for. Eff. mAs kV 120 J XH Organ characteristic: Abdomen CTDIvol (32cm): mGy DLP: mGy*cm 7 9 10 11 12 SIEMENS siemens.com/healthineers Healthineers Job Aid |How to Configure and Use CARE KV Effective Date: 8/16/2016 | Quality 330 2. CARE KV - On With CARE KV turned On, the kV entry on the routine card is dimmed. The most appropriate kV will be selected by the system, based on: The reference kV that has been populated in the IQ definition box The position of the dose optimization slider set for the current type of examination (non- contrast, soft tissue with contrast, vascular/CTA) The patient's size CARE Dose4D CARE KV On Quality ref. mAs 210 2 Ref. kV 120 Eff. mAs kV Dose saving optimized for. Organ characteristic: Abdomen CTDIvol (32cm): mGy DLP: mGy*cm 3 5 7 10 11 12 N - *Generally, the Ref. KV is considered to be the kV that would be manually set on a 70 - 80kg/170lb patient for a specific body part/examination type to attain a desired acceptable image quality. 3. CARE KV - Semi With CARE KV on Semi, the user can manually set the desired kV value and the eff. mAs will be calculated based on: The position of the dose optimization slider set for the current type of examination (non- contrast, soft tissue with contrast, vascular/CTA) The patient's size CARE Dose4D M CARE KV Semi Quality ref. mAs 210 Ref. kV 120 Eff. mAs Dose saving optimized for. kV 120 Organ characteristic: Abdomen 70 80 CTDIvol (32cm): mGy DLP 100 3 S 7 120 11 12 - - 140 Semi mode is useful in instances when a fixed kV is desired in combination with the appropriate mA value, e.g. follow up studies in which the same kV is necessary to produce similar HU values. Siemens Healthineers Services Page 2 of 3 Job Aid |How to Configure and Use CARE KV Effective Date: 8/16/2016 | Quality 330 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3
- TruePoint
- mCT
- mCT 20 Excel
- As
- Flash
- Emotion