How to Configure Dose Alerts Somaris X

How to Configure Dose Alerts Somaris X

Configuring Dose Alerts Job Aid SOMARIS X VA30 CT SOMATOM go.VA30; CT SOMATOM X.cite VA30 This job aid will walk you through the steps to configure dose alerts on SOMATOM go. or SOMATOM X.cite with VA30 software. Step 1: Login as a Super User to configure dose alert values. Step 2: Access the settings wheel menu, a) click on clinical configuration, then b) examination configuration, and then c) dose-alert. Here you can set thresholds for both adult and child examinations. istrator Y 2 = Configuration Pane. Administration Portal Clinical Configuration Check up Daily QA Calibration Resume syngo Remote Assist Screen recorder SaveLog Examination Configuration Dose Configuration Contrast Modulation Report Alert Dose Cardiac Adult Child Image CTDIvol 1,000 + mGy CTDIvol 500 + mGy Patient DLP off = mGy cm DLP off + mGy cm Master Template Effective Date: 3/5/2020 | HOOD05162003074494 SIEMENS Job Aid Effective Date: 11/24/2020 | HOOD05162003145043 Page 1 of 4 Healthineers Job Aid | Configuring Dose Alerts SOMARIS X Effective Date: 11/24/2020 | HOOD05162003145043 NOTE: • Dose Alert monitors the maximum of accumulated CTDIvol as well as the accumulated DLP in all z-positions of the entire exam. • When there is a potential to exceed the threshold, the corresponding scan range and parameters displays a red warning icon and a dose message box opens. User must enter user name and dose alert password to proceed! Dose Alert × A A dose alert value will be exceeded! The accumulated CTDIvol (34.30 mGy) will locally exceed the alert value (10 mGy for Adult) The accumulated DLP (967.4 mGy*cm) will locally exceed the alert value (100 mGy"cm for Adult) 4.4s Please reconsider the current examination procedure. Hint The currently used scan protocol cannot be saved! 2 User Name (mandatory) Richard Diagnostic Reason obese Password ..... Confirm Cancel Guide&GO • In the case of Guide&Go, there is an additional option to “ Do Not Show Again”. If you enable this check box and confirm the dose alert message, the dose alert will not show again for the following Guide&Go scans. Dose Alert X A dose alert value will be exceeded! The accumulated CTDIvol (34.30 mGy) will locally exceed the alert value (10 mGy for Adult). The accumulated DLP (967.4 mGy*cm) will locally exceed the alert value (100 mGy*cm for Adult). Please reconsider the current examination procedure. Hint: The currently used scan protocol cannot be saved! User Name (mandatory) Richard Diagnostic Reason obese Password ..... Confirm Cancel Do Not Show Again Master Template Effective Date: 3/5/2020 | HOOD05162003074494 SIEMENS Job Aid Effective Date: 11/24/2020 | HOOD05162003145043 Page 2 of 4 Healthineers Job Aid | Configuring Dose Alerts SOMARIS X Effective Date: 11/24/2020 | HOOD05162003145043 Reviewing Dose Alert Information To review dose alert information for a specific scan event: Step 1: Select dose report series on the patient browser. Step 2: Right mouse button select on image stamp to get menu. Step 3: Select Display DICOM Header to access info. LO View&GO Print Open Open with DICOM Q/R Series Study Ar + Series Number Series Description Modality # Instances in .. Series Archived Exporte 0.60 CT - 2 0.60 CT 502 Patient Protocol CT 503 Dose Report SR 504 Examination Report SR Open View as Read-Cnly @ Open with View as Read-Only with Set Archive state Instances Correct Split to New Series Delete Del Display DICOM Header Display DICOM Header 2020.06.08-22:22:51-DST-Trauma (18/11/1858) Mean CTDIvol: 0.01 mGy CTDIw Phantom Type: [113691,DCM, 1EC Body Dosimetry Phantom'] DLP. 0.49 mGycm Dose Check Alert Details: DLP Alert Value Configured: [R-0038D, SRT,'No'] CTDIvol Alert Value Configured: [R-0038D,SRT,'Yes'] CTDIvol Alert Value: 1000 mGycm Accumulated DLP Forward Estimate: 0.49 mGycm Accumulated CTDIvol Forward Estimate: 0.01 mGy Reason for Proceeding: Person Name Person Role in Procedure: [113850,DCM, "Irradiation Authorizing] Dose Check Notification Details: DLP Notification Value Configured: [R-0038D, SRT,'No'] CTDIvol Notification Value Configured: [R-0038D, SRT,'No'] CTDIvol Forward Estimate: 0.01 mGy n for Proceeding "" Master Template Effective Date: 3/5/2020 | HOOD05162003074494 SIEMENS Job Aid Effective Date: 11/24/2020 | HOOD05162003145043 Page 3 of 4 Healthineers Job Aid | Configuring Dose Alerts SOMARIS X Effective Date: 11/24/2020 | HOOD05162003145043 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 NOTE: Dose alert password must be set and managed by authorized user at the facility in User & Role management. If you have questions about password or need to modify it, contact authorized user or the CCC for assistance. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Master Template Effective Date: 3/5/2020 | HOOD05162003074494 SIEMENS Job Aid Effective Date: 11/24/2020 | HOOD05162003145043 Page 4 of 4 Healthineers