PEPconnect

How to Create Radiologist Report Flow in syngo. Breast Care

How to Create Radiologist Report Flow in syngo. Breast Care

How to Create a Radiologist Report Flow in syngo.Breast Care 1. Double Click on a study and it will load onto the high resolution monitors. SIEMENS Megan Thompson Server: 10.1.1.58 Mammo Assign XP Prior bilateral, ... Female 10 MG Breast x 10/10/1940 P1 MG Breast MG Reading Findings Navigator Name Value Source 1 HE 9:35 AM 2. Click on the wrench icon in the control area. MG Breast MG Reading Prior 1G SIEMENS www.usa.siemens.com/healthcare 718 Effective 9/8/2016 Page 1 of 3 3. A box will pop up. Click on “report flow”. MG Breast Configuration General ReportFlow™ Global Settings Marking studies "old" · Off After 6 months Default OK Save Cancel 4. Click on the “Plus” icon to add a report flow step. To the right choose the layout you desire and select the tools you would like applied. MG Breast Configuration X General ReportFlow™ Global Settings ReportFlow™ Steps Layouts C.CC Display Tiling Timepoint Laterality Quadruple Current Right C.CC Double Prior Left Single Mixed Mixed C.CCID Layout PC.CC.CWR PC.CC.CWL C.MLO New Layout LO/CC C.ML C C C.MLO C.MLOID C.MLO C.CC C.ML C.MLO/CC.CWR PC.MLO.CWR PC.MLO.CWL C.CC/MLO.CWR|C.M. C.MLO/CC.CWL C.MLO/ML.CWR C.MLO/ML.CWL C.MLO/CC Tools C.MS.CWLIC.MLO/C. Tools <><> C.MLO/CC Fit to Segment Inverted < > C.CC Fit Object to Segment CAD Fit to Acquisition Size + True Size Structured Roaming OK Save Cancel Adding report flow step SIEMENS www.usa.siemens.com/healthcare Page 2 of 3 5. Use the arrows on the left to move the workflow step to desire order in the workflow. Select the step and choose the up or down arrow. MG Breast Configuration General ReportFlow™ Global Settings ReportFlow™ Steps Layouts C.CC Display Tiling Timepoint Laterality Quadruple C.CC Double Prior Loft Single Mixed Mixed C.CCID PC.CC.CWR PC.CC.CWL C.MLO New Layout 1x1 PC.MLOICC C.MLO C.MLO C C C . MLOID C.MLO C.Cc C.ML C.MLO/CC.CWR PC.MLO.CWR SICE PC.MLO.CWL CK MAC C.CC/MLO.CWR|C.M. C.MLO/CC.CWL C.MLO/ML.CWR C.MLO/ML.CWL .MLO/CC SPOT >> C.MS.CWL|C.MLO/C. Tools Fit to Segment GE C.CC Inverted Fit Object to Segment CAD Fit to Acquisition Size True Size Structured Roaming OK Save Cancel 6. Repeat steps 4 and 5 until you have all of the desired steps in the workflow. 7. To delete any unwanted steps, select the step, and use the “minus” icon. MG Breast Configuration General ReportFlow™ Global Settings ReportFlow™ Steps Layouts > C.CC Display Tiling Timepoint Laterality Quadruple Current Right C C.CC Double Prior Left Mixed Mixed C.CCID C C PC.CC.CWR PC.CC.CWL C.MLO New Layout 1x1 PC.MLO/CC >< > C.MLO C.MLO K C S C C.MLOID C.MLO C.CC C.ML C.MLO/CC.CWR PC.MLO.CWR > PC.MLO.CWL CC MAC SPor C.CC/MLO.CWR|C.M. C.MLO/CC.CWL C.MLO/ML.CWR C.MLO/ML.CWL C.MLO/CC FOT- > > C.MS.CWL|C.MLO/C Tools C.MLO/CC . Fit to Segment Inverted C C.CC Fit Object to Segment CAD C Fit to Acquisition Size + True Size Structured Roaming 15 OK Save Cancel 8. Click “Save”. (Note that if you are signed in as administrator you can choose to save the report flow for all users or current user.) SIEMENS www.usa.siemens.com/healthcare Page 3 of 3

  • syngo MultiModality Workplace