How to Launch a Third Party
How to Launch a Third Party
syngo plaza - 3 rd Party Configuration and Launch 1. Open the Viewing Settings dialog box, and click the Other Applications tab card. Viewer Settings General Image Text | Spine Labeling | Window Level Presets|Other Applications | Smart Select | Shortcut Keys Corner Menu | Priors Loading Token View List of applications configured Type or select the name of the application: Browse .. Enter parameters: syngo.via Enter display name: Advanced ... Save Remove New OK Cancel Help 2. To create a new call, click New. The enter boxes on the right side of the tab card are cleared. 3. Enter the data for the application. Type in the name of the application path and name of the program file: for example, http://myserver/servlet/WebEPR. Click Browse to select the file from the file system. Enter parameters. Transfer parameters DICOM tags can also be passed: /DICTAG:XXXX,YYYY;this passes the information that is assigned to this DICOM tag. You can pass up to five of these DICTAG parameters. /DICNAME; this passes the current name of the DICOM directory. Example: http://myserver/servlet/WebEPR?patid=DICTAG:0010,0020. The effect of this entry is that the internet browser is started, the http://myserver/servlet/WebEPR site is loaded, and current patient ID (parameter patid) is passed. Enter display name. Enter the name with which the application will be displayed in the list of OEM applications. Example: Internet. syngo.via. If selected, selected data can be sent from the Patient List and the Viewer to syngo.via by clicking an icon. 4. You can search for and select the application in the file system. SIEMENS www.usa.siemens.com/healthcare 702 Effective date 9/8/2016 Page 1 of 4 Click the Browse button. The Open dialog box opens. Select an * .exe file and click the Open button. The path of this exe file is entered in the Type or select the name… field. 5. Click the Advanced… button, to enable and define the auto launch function of the selected OEM application. The Advanced Settings dialog box opens. Advanced Settings Auto Launch On Start of Load Modality : v On Completion of Load Study desc : Con Closing a Patient Tab Organ : On Activation of Patient Tab + Modality Study Description Organ Auto Launch on OEM image call-up OK Cancel Auto Launch if enabled, the selected OEM application is launched according to the selected criteria. You can select one of the following criteria. o On Start of Load – Loads a study in the selected application at the time as it is being loaded at syngo.plaza Viewer. o On Completed of Load – After loading a study in syngo.plaza Viewer, the study will be loaded into the selected application. o On Closing a Patient Tab – Launches a close command to the selected application when a patient tab is closed. You can further define one of more study specific criteria for auto launch: o Modality – Launches the application if studies from the selected modality are loaded, or closed. o Study Description – Launches the application if studies with the selected study description are loaded, or closed. o Organ – Launches the application if studies with the selected organ are loaded, or closed. To confirm the auto launch settings, click OK. The Advanced Settings dialog box is closed. Click Save. SIEMENS www.usa.siemens.com/healthcare Page 2 of 4 6. To launch a 3rd party application: In the Viewer, select the image whose parameters you wish to transfer to the OEM application. Click the OEM Application icon on the tool palette on the Viewer task card. o If only one application is configured as an OEM application, it is started immediately. o If several OEM applications are configured, a selection list opens. All configured OEM applications are listed there. o Click the application that you want to start. o The icon is dimmed if no OEM application has been defined. SIEMENS www.usa.siemens.com/healthcare Page 3 of 4
- syngo MultiModality Workplace