How to Perform 3D/3D Fusion
How to Perform 3D/3D Fusion
How to Perform 3D-3D Fusion Artis Q, Artis zee, Artis Zen 1. Perform 5s DR, 8s DR, or 20s DR spin. Re- construction will load into Inspace, once loaded, close Inspace and load CT/MR (Reference series) image first. 2. In the Inspace drop down (at top of screen) InSpace Show Mode View orient About? InSide InSpace Website > select Open Additional Volume (the Apply Modality Preset .. Save Modality Preset. Patient Browser will display) > highlight Apply Lighting Preset ... Save Lighting Preset the 3D reconstruction (Model series) and Apply Study Bookmark ... Ctrl-L Save Study Bookmark As. Save Study Bookmark Ctrl-S load. Open Additional Volume Ctrl-O Close Volume Ctrlv Film All Views Save Image Save Image As Export Image ... Startup Wizard Settings. Reset to Defaults 3. Select tools > select Fusion icon. Then Register > initial. Clip | Tools | Measure |X-Ray InSpac 3D/3D Fusion: Registers 2 volumes/datasets. And 4. Select manual/visual icon and adjust the ERDAD Fusion Volume Solection alignment, so the images are Registration Mer Reastration Mode superimposed. -ruarvisuis Registrados SIEMENS siemens.com/healthineers Healthineers . Job Aid | How to Perform 3D-3D Fusion Effective Date: 08/16/2016 | Quality HOOD0516200893402 5. Select Auto > under Automatic CEDAD Fusion Volume Selection Registration Registration, select Pre-Aligned, if manual Registration Metrix Defaul Registration Mode adjustments were made, otherwise, select Fully automatic > Register. Automatic Registration Fully automatic (pro-registration dena by application) Pre-atcned (takes pre-registration of the user into account) Stant Automatic Registrétión: Register Help Close 6. Saving registration > enter name in Registration Matrix field > select floppy Registration Matrix |manually icon. 7. Select iPilot Live or Dynamic from the x-ray iPilot Live X sub task card in InSpace. * The following message may display. The user confirms A Mo_CT_Standard_Heart_Abd, 19190402. F. 1234 of the the message, if the patients are identical. currently selected volume differs from last reconstructed 3DAngio / DynaCT data setl Confirm that patients are identical OK Cance Siemens Healthineers Services Page 2 of 3 Job Aid | How to Perform 3D-3D Fusion Effective Date: 08/16/2016 | Quality HOOD0516200893402 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3
- Artis Q
- Artis zee
- Artis Zen