How to Reconstruct Images from RTD Data

How to Reconstruct Images from RTD Data step by step

How to Reconstruct Images from RTD Data Computed Tomography RTD - Real Time Display: the preliminary images seen during the acquisition of a scan range. In order to display images quickly, RTD images are purposefully generated with gaps using a reduced resolution and no specialty filters. As such, RTD images are intended for localization and reconstruction planning only and should not be used for diagnosis. The following is a guide to creating an optimal, diagnostic dataset from RTD images. 1. Perform an appropriate scan of the desired anatomy. The first reconstruction box will display RT indicating that these are RTD images and that most reconstruction parameters have not been applied to this recon job. Topogram Spine RT 2. Adjust the magenta boxes in Segments 1 and 2 to graphically define the desired x -, y- and z- axis reconstruction parameters. The entire box may be repositioned using the bulls-eye in the center. Drag the top and bottom of the box to set the recon begin and end locations in the z- axis. Adjust the size of the box to define the desired Display Field of View (DFOV). Scroll through the images in Segment 2 to verify that DFOV is appropriate for the entire scan range. 1.13-12:44:28-ST Hospital 13.03.13-12:44:28-STD-Specials . Hospital 13.03.13-12:44:28-STD-1 3.1 ... BOMATOM Definition AS 13.03.13-12:44:28-STD-1.3.1. SOMATOM Definition AS CT 20128 CT 20128 H-SP-CR 13-Mar-2013 H-SP 13-Mar-2013 12:48:29.09 12:50:03.21 2 IMA 1 101 IMA 24 TOP 2 RTD 3 SP .- 201.0 SP-436,1 KV 100 KV 120 eff.mAs 167 mA 60 refmAs 382 TI 5.3 11.0 OT 0.0 GT 0.0 SL 5.0/128x0.6/p.28 512 0/0 118 0/44 T801UOPO 1b 17% B40s SBRO A4b SIEMENS siemens.com/healthineers Healthineers Job Aid | How to Reconstruct Images from RTD Data Effective Date: 8/16/2016 | Quality 635 3. Press RECON. Verify that the resulting images include the desired anatomy. Recon NOTE: Prior to reconstructing RT images, a temporary folder with the series name followed by RTD (i.e. "Abdomen RTD") is created in the local database. This folder should not be sent to PACS, as the images are not of diagnostic quality. 13.03.13-08:00:35- 13.03.13-12:18:04-S Local Database 13.03.13-12:44:2 Spine Spine_€ [101] Spine RTD JETZT Prot 11111 Prot Scheduler 3 PHASE ABD [101] Spine RTData THTTT DVD-RW AS+_AAA, CAP_Ar [2] Topogram 0.6 T80f DVD-ROM AS+CarotidCTA [1] Topogram 0.6 T80f Siemens Healthineers Services Page 2 of 3 Job Aid | How to Reconstruct Images from RTD Data Effective Date: 8/16/2016 | Quality 635 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3