PEPconnect

How to Use FAST Spine

How to Use FAST Spine step by step

How to Use FAST Spine Computed Tomography FAST Spine is a workflow enhancement tool that facilitates the automatic creation of anatomically-oriented spine reconstructions based on a 3D volume. 1. In the Recon card, select 3D as the Recon job type, and from the drop down menu, choose the desired type of spine reconstruction:  Spine Oblique - generates coronal and sagittal reconstructions aligned to the curvature of the spine  Spine Disc - generates a small reconstruction range aligned to a specific disc space  Spine Vertebra - generates a small reconstruction range aligned to a specific vertebra  Spine Multi - generates paraxial reconstructions orthogonal to the spinal canal Recon job 2 3 4 5 6 8 Series description Spine 3.0 MPR ax Slice 3.0 mm Recon job type · Axial O 3D SAFIRE M Strength 3 Recon axis axial Algorithm 130s medium smooth Type oblique FAST M Window Spine axi al coronal sagittal spine oblique spine disc FoV 137 mmx 137 mm 2 Image order spine vertebra spine multi Increment 3.0 mm No. of images 81 Comments Routine Scan Recon Auto Tasking 2. The system will perform a background reconstruction and an auto detection of the spine anatomy. abc Base: Tho ThorAbd RTD abc Detecting IIIIIIIIIIIII|||||| Base: Spine Matrix 256 SIEMENS siemens.com/healthineers Healthineers . Job Aid | How to Use FAST Spine Effective Date: 8/16/2016| Quality HOOD05162001908402 3. When done, the anatomy will be displayed in coronal, axial, and sagittal segments with labelling of individual vertebral bodies and identification of disc spaces done automatically.  L3 - defines a vertebral body  L5/S1 - defines a disc space  T3-T6 - defines a range 13.03.13-12:44:28-STD-Speci ... Hospital 13.03.13-12:44:28-STD-Spec ... AHR Hospital 13.03.13-12:44:28-STD-Speci ... Hospital 13.03.13-12:44-28-STD.1 .... 13.03.13-12:44:28-STD-1 .... 13.03.13-12:44:28-STD-1 ... 18.Nov. 1858, 0, 154Y 18.Nov 1858, 0. 154Y 18.Nov 1858, 0. 154Y 13.Mas-20:13 13-Ma+-2013 13-Mar-2013 12:40:59.49 12:49:59.49 12:49:50.40 MPR 3 MPR 3 MPR 3 RFP 10cm A F SL 3.0 340 SL30 48 SL 30 4. Review all labels and disc space angulations for accuracy. Changes can be made using the tools on the Editing Tool Bar. abc Base: Spine Matrix 256 . Add/Remove Disc - Select Delete Disc and click on disc space to be deleted Screenshots Hospital Screenshots Hospital 000010 000010 "00-Sep-2000, 0. 12M "00-Sep-2000, 0. 12M 00.Sep-2010 00-Sep-2010 15:07:39,20 15:07:39.20 T2 MERZ T2 T4 T4 TB TO 17 10cm TO L30 SL 30 Delete Disc V V Base: Spine Matrix 256 Base: Spine Matrix 256 Siemens Healthineers Services Page 2 of 4 Job Aid | How to Use FAST Spine Effective Date: 8/16/2016| Quality HOOD05162001908402 · Edit Vertebral Label - Click Apply Vetebra Label to add or edit a label x 1 X Screenshots 090010 "09.Sep-2009. 0. 12M 09-Sep-2010 15:07:30.20 MPR 2 x T5 SL 3.0 5. If necessary, adjust disc space angulations in coronal and/or sagittal images, and change the Field of View in the axial segment to include anatomy of interest. 13.03.13-12:44:20-STD-Spec ... AHR Hospital 13.03.13-12:44:28-STO.1. "18.Now 1838. 0. 154Y 13 Mai-2013 12:40:350.40 MPR 3 T5 REP TO H10cm SL 3.0 6. When all labels and disc spaces are identified appropriately, confirm the segmentation by clicking the check mark. 7. Confirm that the reconstruction parameters - including slice thickness, slice increment, kernel/algorithm, and image order - are appropriate, and click the Recon button. Recon Siemens Healthineers Services Page 3 of 4 Job Aid | How to Use FAST Spine Effective Date: 8/16/2016| Quality HOOD05162001908402 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 4 of 4

  • as
  • flash
  • emotion
  • open spirit