iFlow
iFlow
iFlow Interventional Radiography: Cardiac 1. Acquire a DSA acquisition. Transfer to the Syngo Workplace. load into the Angio Tab. Select the iFlow icon. 2. Move the cursor over the image. The time of maximum concentration is displayed beneath the cursor. 3. Left-click to mark a point on the image. To delete marks, right-click and select delete all markers. 4. In the adjust TAB, change the duration and starting point: 6.67s A. Is accomplished by clicking on the arrow buttons below duration and starting. This changes the first image and the duration of $/45.33s images displayed (This defines the section of the scene that is computed). Depress the middle button: i. Upward = increasing start time ii. Downward= decreasing start time iii. Toward the right= increased duration iv. Toward the left= decreased duration B. Or enter the number directly. 5. Auto Pixel Shifting and Anatomical background are possible in iFlow. 6. Right-click in the image and select the "Time-versus-Contrast Intensity Curve." 7. Moving the cursor over the image dynamically updates the graph. Creating a Region Of Interest (ROI) to determine the extent of perfusion of a region: a. A maximum of four can be created b. Select the ROI icon c. Chose the ROI type i.e. circle, rectangle, or polygonal: i. Click and drag for the circle and rectangle to desired size ii. Click points to draw outline and double click to finish region for polygonal 8. Storing an iFlow image: SM a. Use the Store Monitor icon b. Export Image As ... c. Copy to film sheet 9. Click on the iFlow icon to close. SIEMENS siemens.com/healthineers Healthineers . Job Aid | iFlow Effective Date: 09/08/2016 | Quality HOOD0516200130431 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2
- Artis zee
- Artis Zeego