IMMULITE® 2000 Immunoassay System Competency Checklist
Education resource material designed to document competency mastery on-the-job. This Competency Checklist represents all learning objectives for this training area.
IMMULITE® 2000 Immunoassay System Competency Checklist Once an employee has acquired the necessary knowledge and skills to perform basic operation tasks this checklist can be used to observe the employee perform the required tasks for their core job responsibilities and to document demonstrated competency. The observer places their initials and date beside the task when it is performed successfully. Successful completion for each task is determined by the facility. The standards used to evaluate can be documented in the “Criteria” section below. Use the area on the last page to record comments or areas of improvement. If necessary, the observer can record recommended next steps of action for areas of improvement or development opportunities. When all required tasks are completed, the supervisor and employee sign and date this document as a record of completion. Criteria - Standards for successful completion of each task (e.g. Accuracy, Time, Quality, etc.): Observer’s Initials and Completion Date Topic/Tasks System Overview Locate the system components and identify the function of each component Locate and identify the consumables Navigate to the Home screen, Bead and Reagent screen, Help screen, and the LIS screen Sample Processing Load and unload samples Run patient samples with and without an LIS Access the Sample Tubes in Racks screen, Display/Edit screen, and Review screen to retrieve sample information Order unbarcoded patient samples Run patient samples using microsample tubes Add a test to a sample in progress Assign various worklist options to samples Adjustment Identify the kit components Scan the kit barcodes Load the kit components Load and order the adjustors List the adjustment validation guidelines Quality Control Identify the fields on the Control Entry screen Enter a new control Add a test to an existing control Load and order barcoded controls Run controls without barcodes Daily Maintenance Log off the software and restart the computer Perform Daily Probe Cleaning Launch the software Check consumables Prime the substrate Prime the DRDs and water probe Weekly Maintenance Identify Weekly Maintenance Procedures Perform Weekly Maintenance Procedures Monthly/Quarterly Maintenance Quality # HILS1916 Effective Date: 06/09/2017 Page 1 of 2 SIEMENS siemens.com/healthineers Healthineers IMMULITE® 2000 Immunoassay System Competency Checklist Identify Monthly Maintenance Procedures Perform Quarterly Maintenance Procedure Troubleshooting Recall the Tube Journey Locate and Review the Event Log and Day Error Log Identify and Resolve Common Errors Menu Options Navigate Menu Options Utilize Tools to monitor the system Utilize Configurations to setup the system Allergy Identify and load the allergy kit components Run allergy adjustors, controls, and patients Comments Areas of Improvement Next Steps Primary Operator Secondary Operator has been trained on the above documented tasks Supervisor: Employee: Date: Quality # HILS1916 Effective Date: 06/09/2017 Page 2 of 2 SIEMENS siemens.com/healthineers Healthineers
- imulite
- immullite
- imullite
- competency
- training
- mentor
- checklist
- consolidated