Inline Ventricular Function (E-line)
Job Aid for Inline Ventricular Function
Inline Ventricular Function (E-line) syngo MR Systems with E-line 1. Locate the InlineVF sequence in the Dot Cockpit SIEMENS SIEMENS >> heart > function > BEAT_Cine_TrueFISP Edit Q retrospective gating head cine_tf2d12 retro IPAT 00:08 c-spine t-spine I-spine cine_tf2d14 retro IPAT arryth 00:07 whole-spine TimCT whole-spine ventricular volume_ neck soft tissue thorax cine_tr2d13_retro_IPAT_10sl_inVF 01:20 heart Cardiac Dot Engine radial localizer morphology cine_tf2d13_radial_retro 00:10 function BEAT Cine FLASH BEAT Cine TrueFISP prospective triggered BEAT FrequencyScouts BEAT Tagging cine_tf2d12_prosp_TPAT 00:06 dynamic tissue characterization cine tf2d15 prosp_TPAT 5slices 00: 16 MyoMaps flow real-time angiography breast cine_realtime_tf2d_10sl_trig_TPAT3+ 00:08. abdomen pelvis female pelvis male shoulder elbow wrist » hand 2. InlineVF setting is found on the Cardiac tab within the Inline tab a. Under Inline Evaluation dropdown select Ventricular Function Genera TA: 1:20 PM: REF PAT: 3 Voxel size: 1.5×1.5×8.0mm Rel SNR: 1.00 tri Protocol Parameters Voice Commands Routine Contrast Resolution Geometry System Physio io Inline Sequence Common Cardiac MIP Composing Execution Image Management Inline Evaluation Ventricular A Auto Load Save original images v Ventricular Function Copy References Magn. preparation Restart InlineVF Contrasts TE 1.46 ms TR 43. 16 ms Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 OK Cancel SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Job Aid | Inline Ventricular Function (E-line) Effective Date: 06/02/2020 | HOOD05162003092559 3. The Images are Saved in an InlineVF series with Automatic Contours and Base Planes drawn on the images SIM Hospital SIM 3/31/1974, M, 62Y Aera STUDY 2 MR D13 1/27/2012 11:25:21 AM 31 IMA 2 / 3 MF 1.00 AC 1 p2 M/RETRO/NORM/DIS2D 960*768 inline_VF_ Results 647 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 2 of 4 Job Aid | Inline Ventricular Function (E-line) Effective Date: 06/02/2020 | HOOD05162003092559 4. Result tables are saved in the series folder in the Patient Browser a. The result tables can be viewed in the Viewing Task Card SIM Hospita SIM 3/31/1974, M, 62Y 1/27/2012 MR DIS 31 IMA 1 / 3 Left Ventricular Function Absolute Normalized* Ejection Fraction EF 50 % End Diastolic Volume EDV 106 ml 62 ml/m^2 End Systolic Volume ESV 53 ml 31 ml/m^2 Stroke Volume SV 52 ml 31 ml/m^2 Cardiac Output co 2.9 l/min Cardiac Index CI 1.7 l/min/m^2 Average Heart Rate HR 55 bpm Normalized to patient surface area .71 m^2 Patient height 1.58 m Patient weight 69 kg Check ED & ES. Computer estimated ED & ES settings may not be accurate. Check contours. Computer generated contours may not correspond to anatomy. Results will be different when loaded into ArgusVF. MF 1. p2 SC/BLACK IMAGE 024+1024 inline_VF_Results 5. Restart Inline VF a. To be used if slices are repeated for better image quality b. For the repeated sequence Select Inline > Cardiac Tab c. Under Inline Evaluation dropdown select Restart Inline VF Note: Calculation with repeated slices will only be performed if Inline VF is selected > cine_t12d13_retro_IPAT_10sl_inVF General TA: 1:20 PM: REF PAT: 3 Voxel size: 1.5x1.5x8.0mm Rel. SNR: 1.00 : tfi Protocol Parameters sequence Voice Commands Routine Contrast Resolution Geometry System Physio Inline Common Cardiac Execution MIP Composing Image Management Inline Evaluation Restart Inli Off Auto Load Save original images Ventricular Function Copy References Magn preparation Restart InlineVF Contrasts TE 1.46 ms TR 43. 16 ms OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 3 of 4 Job Aid | Inline Ventricular Function (E-line) Effective Date: 06/02/2020 | HOOD05162003092559 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 4 of 4
- Inline Ventricular Function (E-line)