ACUSON Juniper™ eSieScan Workflow Protocols - VA10 & VB10 | 1.5 Software
This quick reference guide shows you how to use eSieScan™ workflow protocols.
ACUSON Juniper ultrasound system VB10 SW Release eSieScan Workflow Protocols Quick Reference Card SIEMENS Healthineers ACUSON Juniper siemens-healthineers.com/juniper Creating an eSieScan Protocol for an advanced workflow Step 1 Step 4 • Select the configuration menu icon • Add Protocol Name, select Progression, and End Protocol Behavior Step 2 Protocol Name Adult Echo eSieScan Progression • Select eSieScan from menu options Automatic Manual Step 3 Automatically ends when all views completed Add Protocol • Select Add Protocol (or Copy End Protocol Behavior a factory default to use as a template) Copy Remain in Acquisition O Enter Review O Enter Report Tip: Protocols can be imported and exported using a USB drive. SIEMENS Healthineers HOOD05162003101617 - June 26, 2020 Step 5 Add View • Select Add View Step 6 View Name : PLAX • Type in View Name Tip: Change order of views using the up / down arrows. Step 7 • Choose major imaging mode(s) from Mode Selection D v Color 2DMode M-Mode Step 8 Measurements • To add a measurement, select Measurements tab Step 9 Application Adult Echo • Select Application, Imaging Mode, and Package / Group • Select desired measurement from list Imaging Mode 2D Tip: eSie Measure workflow acceleration package is available for Package / Group Dimension adult & pediatric cardiac protocols. Step 10 Text & Body Marker • To add text, select Text & Body Marker tab and type desired Text Annotation Text Annotation PLAX LV Step 11 Location • Select positioning of text by clicking anywhere within Patient 10 Hospital Name . SUSXD 2501/2017 033439 the screen and Apply to all Views PLAX LV Apply to all Views 2 siemens-healthineers.com/juniper - HOOD05162003101617 - June 26, 2020 Step 12 Body Marker • To add body marker, select Exam and List Exam Adult Echo List Step 13 MM • Select from available body markers • Body marker will appear on bottom right corner of screen • Modify Transducer Location by activating Transducer Marker Location the blue circle with pointer and adjusting Configuration Tips Workflow Tips • Protocols can be imported / exported with a USB • A protocol can be paused and then resumed at any storage device. time. To pause /resume a protocol, use pause or Protocols can be modified by adding views, resume on the touch screen. You may also pause / • measurements, annotations, and body markers at resume using the Select key. any time. • When a protocol is paused, any additional images that Factory default protocols can be modified. are acquired during the pause will appear in the exam - A view can also be modified at any time, when at the point they were acquired, not at the end of the - not part of a factory default protocol. protocol sequence. • To make a measurement, select the Caliper control and the measurement assigned to that step will be activated. • During Manual Progression, advance to the next view by using either the Select control on the control panel or selecting from the touch screen /thumbnails. • During Automatic Progression, the protocol will automatically advance to the next view. • A view can be repeated; the original image acquired will still remain. • A view can be deleted while in the protocol from the thumbnails. • At the end of the protocol, the system will return to any skipped images. To bypass acquisition of skipped images, select End Study. siemens-healthineers.com/juniper - HOOD05162003101617 - June 26, 2020 3 For the proper use of the software or hardware, please always use At Siemens Healthineers, our purpose is to enable healthcare the Operator Manual or Instructions for Use (hereinafter collectively providers to increase value by empowering them on their journey “Operator Manual”) issued by Siemens Healthineers. This material is towards expanding precision medicine, transforming care delivery, to be used as training material only and shall by no means substitute and improving patient experience, all enabled by digitalizing the Operator Manual. Any material used in this training will not be healthcare. updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the An estimated 5 million patients globally everyday benefit from our training. The Operator Manual shall be used as your main reference, innovative technologies and services in the areas of diagnostic and in particular for relevant safety information like warnings and therapeutic imaging, laboratory diagnostics and molecular medicine, cautions. as well as digital health and enterprise services. Note: Some functions shown in this material are optional and might We are a leading medical technology company with over 170 years not be part of your system. of experience and 18,000 patents globally. With more than 48,000 dedicated colleagues in 75 countries, we will continue to innovate Certain products, product related claims or functionalities described and shape the future of healthcare. in the material (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Juniper, eSieScan, and eSieMeasure are trademarks of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Legal Manufacturer & Published by Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029 siemens-healthineers.com USA Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · 9326 0620 · ©Siemens Medical Solutions USA, Inc., 2020 - HOOD05162003101617 - June 26, 2020
- Juniper
- ACUSON Juniper
- protocols
- workflow protocol
- esiescan