ACUSON Juniper™ Enhanced Needle Visualization

This quick reference guide shows you how to use the needle visualization tool.

ACUSON Juniper* Enhanced Needle Visualization Quick Reference Card ACUSON Juniper Using Enhanced Needle Visualization during in-plane ultrasound guided procedures SIMENS> ACUSON Jumper Step 1 Activate a compatible transducer** and select Needle Visual. from Needle Visual. • the touch screen (or, press an assigned User Defined (UD) key). UD 1 UD 2 UD 3 Step 2 Select L/R Flip if needle approach is preferred from the L/R Flip • opposite side. R Step 3 Select beam Angle to optimize for biopsy target location: Angle Angle Shallow Medium Angle Deep • Shallow - Medium - Deep - The system changes the angle of the dotted line on the image. Step 4 Select Needle Enhancement level: 2 W • Needle Enhance 1 is dimmest level - Needle Enhance 2 is medium brightness ngle Angle Deep Needle Enhance. - dium Needle Enhance 3 is brightest level N - * This product is not commercially available. Future availability cannot be guaranteed. ** Enhanced Needle Visualization is compatible with all ACUSON Juniper ultrasound system linear transducers. SIEMENS Healthineers siemens-healthineers.com/ultrasound HOOD51200274053· © Siemens Medical Solutions USA, Inc., 2018 Best Practice Techniques Clinicians using Enhanced Needle Visualization • should be trained in ultrasound guidance techniques. Use a recommended needle size of 16 to 20 gauge. • Ensure the needle is shown perpendicular to the • direction of the steered beam in the enhanced area. Without Enhanced Needle Visualization Direction of steered beam Enhanced area Unenhanced area With Enhanced Needle Visualization To display Enhanced Needle Visualization on the touch Select Needle Visual. from the drop-down menu in the screen, select System Configuration (icon on the touch desired location. screen) > Soft Keys > 2D Lv. Select Close to exit. 11L4 1213 Add Exam System Configuration Soft Key 2D Needle Visual. Elasticity eSieScan General 1 eneral 2 2D LV 2D Frz CLV C Frz PLV P Frz Display Full FOV Custom Keys Split Soft Keys UID Flip Angle Exam L/R Flip Screen Shallow Angle Medium Angle Deep Needle Enhance. Trapezoid Measurement THI Split Biopsy Miden Text Annotation Biopsy Settings Body Marker Physio Settings Trapezoid Clip Settings Physio Settings > Param Exit LUR Fli Clip Store Needle Visual. Printer Clip Setting Blank To assign Enhanced Needle Visualization System Configuration Custom Keys to a User Defined key, select System Gen General 1 Key Direction General 2 Configuration icon > Custom Keys > Key Increase Zoom Clockwise Counter-Clockwise System Display Depth / Focus Function > User Defined 1, User Defined Configuration Custom Keys Depth C Focus - Move Up Focus Soft Keys 2 or User Defined 3. icon Clockwise Counter-Clockwise Exam C Depth T Focus Increase Depth Select Needle Visual. from the drop- Measurement Steer >> Text Annotation Text A down menu. Body Marker Key Function Text B DVR Select Close to exit. Clip Store Print/Store Needle Visual. Printer Pointer Print/Store 2 Barcode Clip Store Simy Wireless Dual Network eft Pedal Split 4B Utility Right Peda None Archive User Defined 1 Needle Visual. Authorization Service User Defined 2 None User Defined 3 None Configure END Key Not Used Close Study ACUSON Juniper is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Legal Manufacturer & Published by Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029 siemens.com/healthineers USA Phone: +1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · Order No. A91US-482-1C-4A00 · Printed in Germany · 5641 01181. HOOD51200274053· © Siemens Medical Solutions USA, Inc., 2018

  • Juniper
  • ACUSON Juniper
  • needle
  • needle visualization
  • enhanced needle visualization
  • needle visual
  • needle enhance