ACUSON Juniper™ Stress Echo Treadmill Continuous Capture w/ View Control
This quick reference guide shows you how to use stress echo continuous capture with view control.
ACUSON Juniper Stress Echo Treadmill Continuous Capture with View Control Quick Reference Card ACUSON Juniper Healthingets> ACUSON AndPE .......... ................. Step 1 Step 5 Review Stress Echo Configuration To begin acquisition of Rest images, select • • Select New Patient Clip Store • F 4 New Patient Select Clip Store to stop acquisition for the • TIP Patient ID is required to begin an exam current view Select Clip Store again to begin acquisition • ...... . . . . . . . . . . . . . . . . .. Step 2 for the next view in the Rest protocol 5P1 • Select the cardiac transducer Adult Echo Software can be customized to automatically • advance to Selection Mode after each view Select Stress Echo • Add Exam Stress Echo eSieSca ............... .. . . . . . . . . . .. Step 6 Step 3 To select images, • position cursor over A pop-up window appears. Select desired view and select • the desired Stress Echo Protocol the left or right Set key Selected image • Protocol Selection Pharmacology 9$1 Treadmill Continuous outlines in white. 9 Pharmacology Continuous Double-click the left Bicycle or right Set key to Multiple images can be progress to the next TIP selected with a single left 0gb Bicycle continuous or right Set key click. view. Repeat steps for Cancel $1 Treadmill all images. ............ Step 4 Step 7 (View Control) Region of interest (ROI) To capture Post images, select Clip Store • • appears on the image Select Clip Store again to stop acquisition • screen for the current view PLAX ROI Position / Size can • Select Clip Store to begin acquisition for the PSAX • be modified next view in the Post protocol. Repeat steps A4C for all views AZC TIP Select the left or right Set key to move between position In Post continuous capture, all images and size. Select left or right Set key again to confirm. TIP can be acquired under any designated view. SIEMENS Healthineers siemens-healthineers.com/ultrasound HOOD512002826454 · © Siemens Medical Solutions USA, Inc., 2018 ....... ....... . . . . . . . . . . . . . .. Step 8 Step 10 Pause Protocol By View By Stage To end capture, select In Review Mode selected • • Clip Store or Pause clip(s) can be viewed Sort Protocol if additional Stress Echo If desired, select Sort by By Stage Compare • images outside the application are desired Selection Mode View or By Stage Review Mode Compare option is • Once all the Post 1/2 • available images have been acquired, the application “Dog ears” will denote • can be configured to whether multiple images enter Selection Mode were selected automatically Step 11 .................... A General Review and Wall Motion WMS Scoring Step 9 • To choose Post images Scoring (WMS) Option is available for • Stress Echo General Review Select the left or right Set key • 1 up 2x1 2x2 3x2 to select the clip, once selected, the clip will outline in white 3x3 4x3 4x4 5x4 ......... Step 12 Repeat steps until all the desired End Protocol • Page Select End Protocol on the touch screen • Post images are selected 3/27 to end the stress protocol TIP If desired, Layout can be changed. To scroll through clips, select Page and rotate the corresponding control knob. TIP Upon exit from the application, a standard imaging screen will displayed. If desired, capture non-stress images. ACUSON Juniper is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Legal Manufacturer & Published by Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029 siemens.com/healthineers USA Phone: +1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · Order No. A91US-514-1C-4A00 · Printed in Germany · 5641 0218.x HOOD512002826454 · © Siemens Medical Solutions USA, Inc., 2018
- Juniper
- ACUSON Juniper
- stress
- echo
- view control
- continuous capture
- adult
- echocardiography
- adult echo
- pediatric echo