ACUSON Juniper™ Stress Echo Treadmill Continuous Capture w/o View Control
This quick reference guide shows you how to use stress echo continuous capture without view control.
ACUSON Juniper Stress Echo Treadmill Continuous Capture without View Control Quick Reference Card ACUSON Juniper Healthingets> ACUSON AndPE .......... ................. Step 1 Step 5 Review Stress Echo Configuration To begin acquisition of Rest images, select • • Select New Patient Clip Store • F 4 New Patient Select Clip Store to stop acquisition for the • TIP Patient ID is required to begin an exam current view Application will automatically advance to the • ...... . . . . . . . . . . . . . . . . .. Step 2 Selection Mode before entering the next view 5P1 Select the cardiac transducer Adult Echo ................................. • Step 6 Select Stress Echo • Add Exam To choose Rest images • Stress Echo eSieSca in Selection Mode, position cursor and Step 3 select the left or right A pop-up window appears. Select Set key • the desired Stress Echo Protocol Selected clip(s) will • outline in white Protocol Selection Pharmacology 9$1 Treadmill Continuous Select Clip Store again • TIP Multiple images can be selected with a single left or 9 Pharmacology Continuous to begin acquisition right Set key click. Double- for the next view in click the left or right Set key Bicycle the Rest protocol to progress to the next view. 0gb Bicycle continuous Repeat steps for all • Cancel $1 Treadmill images Step 4 Step 7 Region of interest (ROI) To capture all Post images, select Clip Store • • appears on the image Select Clip Store again to stop • screen acquisition once all Post images Pause Protocol ROI Position / Size can are acquired • be modified Pause Protocol if additional images Rest • outside the application are desired PLAX PSAX AAC TIP Select the left or right Set key to move between position and size. Select left or right Set key again to confirm. TIP In Post continuous capture, all images AZC can be acquired under any designated view. SIEMENS Healthineers siemens-healthineers.com/ultrasound HOOD51200282654 · © Siemens Medical Solutions USA, Inc., 2018 ................ ....... . . . . . . . . . . . . . .. Step 8 Step 10 Stress Echo By View By Stage Once all the Post In Review Mode selected • • images have been acquired, the Review Mode Selection Mode clip(s) can be viewed Sort Compare If desired, select Sort by By Stage • application can be View or By Stage configured to enter • Selection Mode Compare option is 1/2 automatically available “Dog ears” will denote • whether multiple images ................ Step 9 were selected In Selection Mode, select Rename • View on the touch panel to 1 up Step 11 2x1 2x2 Bx2 rename clip(s) 4x3 4x4 5x4 A General Review and Wall Motion WMS Scoring • Select the view name first on 3x3 • Scoring (WMS) Option is available for touch panel Page Stress Echo General Review With the left or right Set key 3/27 • choose the desired clip(s) to be ......... renamed. The clip(s) outline in Step 12 white End Protocol Select End Protocol on the touch screen • Repeat steps until all the desired • to end the stress protocol Post images are selected TIP If desired, Layout can be changed. To scroll through clips, select Page and rotate the corresponding control knob. TIP Upon exit from the application, a standard imaging screen will displayed. If desired, non-stress images can be captured. ACUSON Juniper is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Headquarters Legal Manufacturer & Published by Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Henkestr. 127 Ultrasound 91052 Erlangen, Germany 22010 S.E. 51st Street Phone: +49 9131 84-0 Issaquah, WA 98029 siemens.com/healthineers USA Phone: +1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · Order No. A91US-503-1C-4A00 · Printed in Germany · 5641 02180.5 HOOD51200282654 · © Siemens Medical Solutions USA, Inc., 2018
- Juniper
- ACUSON Juniper
- stress
- echo
- view control
- continuous capture
- adult
- echocardiography
- adult echo
- pediatric echo