PEPconnect

Lotus Max Image Numbering and Image Types

This table lists the different types of images and how they are numbered.

Lotus Max: (syngo FLC) Image Numbering and Image Types LUMINOS Lotus Max Image numbering and image types In the following table you can see the different image types and how they will be numbered: Image No. Image type Short description Example (left) (right) # none Single Image 13 single image no. 13 # Tomography image # RAD Radiography RAD S# SER Series, also Ortho series of DSA series SS series no. 5 S#_# SER Image of series (not subtracted) SS_12 series no. 5, series number_image number image no. 12 SL#_# SER Image of a stored Fluoro loop SL6_13 stored Fluoro loop no. 6, series number_image number image no. 13 S#_#-# DSA Image of a DSA series (subtracted) SS_12-4 series no. 5, series number_image number-mask image no. 12, current number mask is image no. 4 none OPAC Opacification image (not stored) - - PO_S# none Stored opacification image PO_SS peak opacification image PO (for peak opacification) series from series no. 5 number none SUM Averaged image (not stored) - - SU_S# none Stored averaged image SU_S6 averaged image of series SU (for sum) series number no. 6 SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date: 5 MAR 2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 03 May 2021 | HOOD05162003188070 Job Aid I Image Numbering and Image Types Effective Date: 05/03/ 2021 | HOOD05162003188071 Image No. Image type Short description Example (left) (right) none LIH LIH (Last Image Hold) image or Fluoro - - loop (not stored) LIH# none Stored LIH image LIH3 3rd stored LIH image SL# none Stored Fluoro loop SL4 4th stored Fluoro loop SL#_# none Image out of a stored Fluoro loop SL4_22 4th stored Fluoro loop, series number_image number image no. 22 SNP_# none Snapshot image SNP_3 snapshot image no. 3 SM_# none Store Monitor image or DICOM SC SM_3 image saved from image image/series no. 3 COP_# none Composed image COP_2 composed image from series no. 2 If manual composition took place, an asterisk* is added to the image number. TW_# none Stored twinview image TW_2 2nd twinview image Q_# none Stored quadview image Q_1 1st quadview image none CAP Captured image, e.g. endoscopic or CAP ultra-sound none REP Medical report image/series R6_2 stored medical report no. 6, image no. 2 none REF# Reference image REF6 6th reference image SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Healthineers Master Template Effective Date: 5 MAR 2020 | HOOD05162003074494 Job Aid Effective Date: 03 May 2021 | HOOD05162003188070 Job Aid I Image Numbering and Image Types Effective Date: 05/03/ 2021 | HOOD05162003188071 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Healthineers Unrestricted