LUMINOS Lotus Max VF11B Optional System Components - Enhanced CARE Package Online Training
This online training introduces the four features of the Enhanced CARE Package to you (VF11B): Take a snapshot during fluoroscopy, auto store fluoro loops using the Proactive FluoroLoop feature, use histogram dose regulation, and magnify clinical images by using digital zoom.
Continue Button Welcome Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 ? LUMINOS Lotus Max Optional System Components Enhanced CARE Package Online Training In this training, we will introduce and explain the four features of the Enhanced CARE Package. Take a snapshot during fluoroscopy Magnify clinical images by using digital zoom Use histogram dose regulation Auto store fluoro loops using the Proactive FluoroLoop feature 1 4 3 2 Welcome [olt_lum-lotus-max_enhanced-care-pack_en_1-1.mp3] Welcome to the Enhanced CARE Package Online Training for the LUMINOS Lotus Max. In this training, we will introduce and explain the four features of the Enhanced CARE Package. We will explain how to take a snapshot, how to auto-store fluoro loops by using the proactive fluoro loop feature, discuss what the new histogram dose regulation is about and talk about zooming into images by using digital zoom. Let’s start with our first topic! Navigation Hints Before you start, we would like to give you a few tips on how to navigate: Table with 2 columns and 4 rows Not all pages contain audio. Some pages invite you to read for yourself or watch a video. All pages show an ? button in the lower right corner. Click the ? button to get a quick guide through the navigation elements. Some pages show an X button in the upper right corner. Click the X button to return to the overview page and not miss any information provided. Some images show a magnifier icon. Click on the icon to see an enlarged view of the image. Another click brings you back to the normal view. Enjoy the course! ? ? Navigation Hints Navigation Help Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Timeline Select the X to close the pop-up. Click Next to continue. Next Layer Slide Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Assessment Slide Snapshot ? Snapshot Mode Snapshot is a dose-saving alternative to a DFR/DR acquisition. Please note: There is no disruption of the fluoroscopy while activating the Snapshot Mode. Select the colored callouts to learn where and how the Snapshot Mode can be activated. Store Snapshots during Fluoro Snapshot Mode [olt_lum-lotus-max_enhanced-care-pack_en_3-1.mp3] With the Snapshot Mode, you can take a snapshot image during fluoroscopy. Snapshot is a dose-saving alternative to a DFR/DR acquisition. You can take a snapshot by using the touchscreen on the control console, the Examination task card on the FLC interface, or by using the wireless footswitch Please note that there is no disruption of the fluoroscopy while activating the Snapshot Mode. Select the colored callouts on the left to learn where and how the Snapshot Mode can be activated. Take a Snapshot by using the Wireless Footswitch During fluoroscopy, press the highlighted button to take a snapshot image. The snapshot function is only active during fluoroscopy. After fluoro, you can use this button to store the last fluoro image (LIH). Snapshot/Store Image/Store LIH Take a Snapshot by using the FLC Interface During fluoroscopy, take a snapshot by using the highlighted icon on the Fluoro tab in the Examination task card. The icon is only active during fluoroscopy. Store the current image Before fluoroscopy, this icon is displayed. Store Snapshot during Fluoro During fluoroscopy, the icon changes to the Store snapshot during fluoro icon. Take a Snapshot by using the Touchscreen During fluoroscopy, press the highlighted icon to take a snapshot image. The snapshot icon is only active during fluoroscopy. ? In this video, we demonstrate on the FLC interface how to take snapshots during fluoroscopy. Select Play to start the video. Snapshot Demonstration Snapshot Demonstration [vid_lum-lotus-max_enhanced-care-pack_snapshot_en_docx] Speakertext: To activate the Snapshot Mode, perform fluoroscopy. During fluoroscopy, select the Store snapshot icon to take a snapshot image. When a snapshot is saved, a save icon appears. You can take as many snapshots as required during fluoroscopy. Please note: When fluoroscopy has ended, the icon changes to the Store the current image icon. If you want to take snapshots again, you have to perform fluoroscopy again. ? Storage of Snapshots All snapshots are automatically stored in the study (Documentation task card). Storage of Snapshots [olt_lum-lotus-max_enhanced-care-pack_en_3-3.mp3] When storing snapshots, all snapshot images are automatically stored in the study. You can access the snapshot images by going to the Documentation task card. Proactive FluoroLoop ? Proactive FluoroLoop The performed fluoro loop is automatically stored in the study (Documentation task card). Select the callouts to learn where and how the auto-store function can be activated manually. Click here to learn how to activate Auto store fluoro loop at system startup in the User Settings. Auto Store Fluoro Loop Proactive FluoroLoop [olt_lum-lotus-max_enhanced-care-pack_en_4-1.mp3] The Proactive FluoroLoop function comprises an auto-store function for all fluoro loops. When activated, the performed fluoro loop is automatically stored in the study in the Documentation task card. You can activate this function on the touchscreen, the Examination task card on the FLC interface, or the wireless footswitch. Select the callouts to learn where and how the auto-store function can be activated manually. You can also activate the automatic storage of fluoro loops at system startup. If configured in the User Settings, it can be activated upon start up of the system automatically. Click here to learn how to turn this function on and off in the USER SETTINGS. Activate at System Startup In the USER SETTINGS, select the Examination Properties. Enable Active at startup. Now, Auto store fluoro loops is activated right after system startup. Store Fluoro Loop 1 2 Activate Auto Store by using the Wireless Footswitch To store fluoro loops automatically by using the wireless footswitch, do the following: To activate Auto store fluoro loop, press the upper right button. Perform fluoroscopy. The fluoro loop is automatically stored in the study. To deactivate Auto store fluoro loop, press the same button again. Store Fluoro Loop Activate Auto Store by using the Touchscreen To store fluoro loops automatically by using the touchscreen, do the following: To activate Auto store fluoro loop, press the highlighted icon. Perform fluoroscopy. The fluoro loop is automatically stored in the study. To deactivate Auto store fluoro loop, press the same icon again. Enable/disable Automatic Storing a Fluoro Loop Activate Auto Store by using the FLC Interface To use the auto store function for fluoro loops, do the following: Activate the Auto store fluoro loop icon on the Fluoro tab of the Examination task card. Perform fluoroscopy. The fluoro loop is automatically stored in the study. To deactivate the auto-store function, select the icon again. Auto Store Fluoro Loop Automatic Storage of a Fluoro Loop The automatic storage of a fluoro loop is indicated by this icon. Auto Store Fluoro Loop The auto-store function is active. Histogram Dose Regulation ? Histogram Dose Regulation Regulates the dose automatically by using the entire collimated image area as its measuring field Used when dealing with different densities (e.g. prosthetics, metal implants) Not possible for RAD or single shot acquisitions If configured, different settings are available Select the callouts to learn where this function can be activated on the FLC interface and touchscreen! Histogram Dose Regulation Histogram Dose Regulation [olt_lum-lotus-max_enhanced-care-pack_en_5-1.mp3] The third feature of the enhanced CARE package is the histogram dose regulation. Histogram dose regulation regulates the dose automatically by using the entire collimated image area as its measuring field. It is used when dealing with different densities, such as prosthetics and metal implants. Please note that histogram dose regulation is not possible for RAD or single shot acquisitions. You can select the histogram dose regulation on the touchscreen or on the FLC interface. If configured, different histogram regulation settings are available and can be selected. Select the callouts to learn where this function can be activated on the FLC interface and touchscreen. Activate Histogram Dose Regulation on FLC Interface Press the measuring field icon to open the drop-down menu. Select the histogram dose regulation function. 1 Activate Histogram Dose Regulation on Touchscreen Press the measuring field icon to open the drop-down menu. Select the histogram dose regulation function. 1 ? This video shows the difference between using a measuring chamber and using histogram dose regulation. Select Play to start the video! Demonstration Demonstration [vid_lum-lotus-max_enhanced-care-pack_histogram-demo_en_v0-2.docx] Digital Zoom ? Digital Zoom Live image zoom No dose increase Let’s try switching to digital zoom! Select the icon in the Setup tab card to toggle to digital zoom. Digital Zoom Toggle between Zoom and Digital Zoom Select this icon to switch to digital zoom. Set the Zoom Stage (Input Format). Digital Zoom [olt_lum-lotus-max_enhanced-care-pack_en_6-1.mp3] With the Enhanced CARE package, you can toggle between the regular Zoom mode and Digital Zoom. In comparison to the regular Zoom mode, Digital Zoom is a live image zoom for clinical images without increasing the dose. You can toggle to digital zoom on the touchscreen in the Setup tab card. If you switch to digital zoom, the digital zoom stages can be selected in the general functions area below. Let’s try switching to digital zoom! Select the icon in the Setup tab card to toggle to digital zoom. Set the Digital Zoom Stage. Toggle between Zoom and Digital Zoom Select this icon to switch to digital zoom. ? Display on FLC interface Digital Zoom Zoom Please note: You can only change the zoom on the touchscreen. Display on FLC interface [olt_lum-lotus-max_enhanced-care-pack_en_6-2.mp3] On the Examination task card of the FLC interface, you can see which zoom is active. Please note: You can only change the zoom on the touchscreen control – and not on the FLC interface. ? Zoom and Digital Zoom Stages Table with 3 columns and 5 rows Zoom stage Icon Input format approx. Full format/Zoom 0 42 cm x 42 cm Zoom 1 30 cm x 30 cm Zoom 2 23 cm x 23 cm Zoom 3 15 cm x 15 cm Table with 3 columns and 5 rows Digital zoom stage Icon Input format approx. Full format/Zoom 0 42 cm x 42 cm Zoom 1 30 cm x 30 cm Zoom 2 23 cm x 23 cm Zoom 3 15 cm x 15 cm Please note: At 30 p/s, only Digital Zoom 0 and Digital Zoom 2 are possible. Zoom and Digital Zoom Stages [olt_lum-lotus-max_enhanced-care-pack_en_6-3.mp3] Here you can see more information regarding the zoom and digital zoom stages. Please note: At 30 p/s, only Digital Zoom 0 and Digital Zoom 2 are possible. Course Review ? Course Review Congratulations. You have completed the Enhanced CARE Package course for the LUMINOS Lotus Max. Select the numbered buttons below to review the material before proceeding to the final assessment. Auto-store fluoro loops using the Proactive FluoroLoop feature Take a snapshot during fluoroscopy 1 1 1 2 2 2 3 3 3 4 4 4 Use histogram dose regulation Magnify clinical images by using digital zoom Course Review Magnify Clinical Images Using Digital Zoom Digital zoom is a live image zoom for clinical images without increasing the dose. On the touchscreen, you can toggle between the regular zoom and digital zoom. When digital zoom is selected, the digital zoom stages can be selected below. On the Examination task card (FLC interface), you can see which zoom is active. At 30 p/s, only Digital Zoom 0 and Digital Zoom 2 are possible. Toggle between Zoom and Digital Zoom Set the Digital Zoom Stage Digital Zoom Use Histogram Dose Regulation Histogram dose regulation regulates the dose automatically. It covers the collimated image area. Select this function as an alternative to the standard measuring fields. You can activate this function on the touchscreen and on the FLC interface. Histogram dose regulation is not possible for RAD or single shot acquisitions. Histogram Dose Regulation Auto Store Fluoro Loops Using Proactive FluoroLoop The Proactive FluoroLoop function comprises an auto-store function for fluoro loops. When activated, the performed fluoro loop is automatically stored in the study (Documentation task card). You can activate this function manually on the Examination task card (FLC interface), the touchscreen, or the wireless footswitch. You can also activate the automatic storage of fluoro loops at system startup via USER SETTINGS > Examination Properties. Auto Store Fluoro Loop Take Snapshots during Fluoroscopy With the snapshot mode, you can take snapshot images during fluoroscopy. The snapshot function is only active during fluoroscopy. Snapshot is a dose-saving alternative to a DFR/DR acquisition. You can take snapshot images on the Examination task card (FLC interface), the touchscreen, or the wireless footswitch. Store Snapshots during Fluoro Disclaimer Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com ? Disclaimer Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate. You may repeat the assessment as many times as needed. Start ? Assessment Select the best answer. ? Question 1 of 6 What is true regarding the Snapshot Mode? Snapshots can only be taken during fluoroscopy. I need to activate the snapshot mode in the Examination Properties. Snapshots can only be taken by using the touchscreen. Snapshots can only be taken by using the touchscreen. Snapshots can only be taken by using the touchscreen. Multiple Choice Incorrect Incorrect Snapshots can be taken by using the touchscreen, FLC interface and, if available, by using the wireless footswitch. Incorrect You do not need to activate the Snapshot Mode in the Examination Properties. Select the best answer. ? Question 2 of 6 On the touchscreen, which icon do you need to press to take snapshot images? 1 2 3 4 1 2 4 3 Multiple Choice Incorrect This is not the icon for taking snapshots. Correct This is not the icon for taking snapshots. Incorrect This is not the icon for taking snapshots. Incorrect Select the best answer. ? Question 3 of 6 On the FLC interface, which icon allows you to store fluoro loops? 1 2 3 3 1 2 Multiple Choice Incorrect This is not the icon for storing fluoro loops. Incorrect Incorrect This is not the icon for storing fluoro loops. Select the best answer. ? Question 4 of 6 How can you activate Auto store fluoro loops at system startup? I go to User Settings > Examination Properties. I press the Auto store fluoro loop icon on the touchscreen for more than 3 seconds. I only need to activate the Auto store fluoro loop function once on the touchscreen. It is active until I deselect it. Multiple Choice Incorrect Incorrect This is not how you activate the auto store function for fluoro loops at system startup. Incorrect This is not how you activate the auto store function for fluoro loops at system startup. Select the best answer. ? Question 5 of 6 How can you activate histogram dose regulation on the FLC interface/touchscreen? 1 2 3 3 1 2 Multiple Choice Incorrect Incorrect This is not the icon for activating histogram dose regulation. Incorrect This is not the icon for activating histogram dose regulation. Select the best answer. ? Question 6 of 6 You want to toggle to Digital Zoom. Which icon do you need to press on the touchscreen? 1 2 3 1 2 3 Multiple Choice Incorrect Pressing this icon would not activate Digital Zoom. Incorrect Incorrect Pressing this icon would not activate Digital Zoom. Assessment Results YOUR SCORE: PASSING SCORE: Review Retry Retry Continue Continue Continue %Results.ScorePercent%Results.ScorePoints% %Results.PassPercent%Results.ScorePoints% ? Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course.. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the LUMINOS Lotus Max Optional System Components – Enhanced CARE Package Online Training. Completion Question Bank 1 HOOD05162003181948 | Effective Date: 27 APR 2021 1.1 Welcome 1.2 Navigation Hints 3.1 Snapshot Mode 3.2 Snapshot Demonstration 3.3 Storage of Snapshots 4.1 Proactive FluoroLoop 5.1 Histogram Dose Regulation 5.2 Demonstration 6.1 Digital Zoom 6.2 Display on FLC interface 6.3 Zoom and Digital Zoom Stages 7.1 Course Review 7.2 Disclaimer 7.3 Assessment 7.11 Completion
- luminos
- lotus
- max
- radiography
- fluoroscopy
- floro
- fluro
- xray
- x-ray
- enhanced
- care
- package
- snpashot
- snapshot
- floroloop
- fluroloop
- fluoroloop
- loop
- histogram
- does
- dose
- regulation
- magnify
- magnification
- zoom
- vf11b