LUMINOS Lotus Max VF11B Optional System Components - Second Plane X-Ray Unit Online Training
This online training introduces hard- and software of the optional and ceiling-suspended X-ray unit to you that is used for second plane acquisitions (VF11B).
Continue Button Untitled Scene Master Template HOOD05162003052540 | Effective Date: 26-Nov-2019 ? LUMINOS Lotus Max Optional System Components Second Plane X-Ray Unit Online Training This online training introduces you to the second plane X-ray unit as an optional system component of the LUMINOS Lotus Max radiography and fluoroscopy system and covers the following three learning objectives: Get to know the hardware components of the ceiling-suspended X-ray unit Understand components and functionalities of the colli-mator and its control panel Learn about the MAXtouch touchscreen user interface (TUI) on the tube 1 3 2 Welcome [Audio file name: audf_llm_sec_plane_olt_welcome.mp3] Welcome to the LUMINOS Lotus Max Optional System Components – Second Plane X-Ray Unit Online Training. This online training introduces you to the second plane X-ray unit as an optional system component of the LUMINOS Lotus Max radiography and fluoroscopy system and covers the following three learning objectives: ? Hints for Navigating this Online Training Before you start, we would like to give you a few tips on how to navigate: Table with 2 columns and 3 rows Not all pages contain audio. Some pages invite you to read for yourself or watch a video. Some pages show an X button in the top right corner. In order to not miss any information provided, click the X button to return to the overview page. Some images show a magnifier icon. Click the icon to see an enlarged view of the image. Another click brings you back to the normal view. Enjoy the course! Hints for Navigating ? LUMINOS Lotus Max – Optional System Components Bucky wall stand for second plane acquisitions Æ Please see online training on PEPconnect Overhead support with X-ray tube and collimator for second plane acquisitions Æ Introduced in this online training Display ceiling suspension Wireless foot switch Æ Please see job aid on PEPconnect Please note: To learn about other optional system components in more detail, please visit the corresponding online trainings in the LUMINOS Lotus Max training area on PEPconnect. Mobile control console on moveable trolley with optional foot switch placed below Optional System Components [Audio file name: audf_llm_sec_plane_olt_optional.mp3] In this online training, we focus the ceiling-suspended X-ray unit available as an optional system component (second plane). In addition to it, there are further optional system components available to complement your LUMINOS Lotus Max system. Please hover over the markers to learn about these system components. Please note: To learn about other optional system components in more detail, please visit the corresponding online training material in the LUMINOS Lotus Max training area on PEPconnect. ? Optional System Components – Examination Room Ceiling-Suspended X-Ray Unit The ceiling-suspended 3D overhead support consists of the following components: Lifting column X-ray tube unit Touchscreen user interface (MAXtouch) Collimator Handles with buttons Use the handles, if you want to manually bring the tube unit into another position (vertical, longitudinal, transverse or rotation). Collimator control panel Ceiling-Suspended X-Ray Unit [Audio file name: audf_llm_sec_plane_olt_csxrt.mp3] The ceiling-suspended X-ray unit is used to perform second plane acquisitions. You control the movements of the 3D overhead support with the aid of the handles and the MAXtouch, the touchscreen user interface. The display on the MAXtouch gives you various information, for example about the position of the support (Source-to-Image Distance – SID, tube angle, generator settings, patient name, and organ programs). Make yourself familiar with the single hardware components of the ceiling-suspended X-ray unit. ? Touchscreen User Interface – MAXtouch The MAXtouch is a color touchscreen user interface for control of multiple functions. The touchscreen corrects its display orientation from portrait to landscape, when the X-ray tube is tilted by 90°. Please note: Various functions of the MAXtouch are available as well on the Touchscreen User Interface (TUI) of the system remote control console. MAXtouch portrait orientation MAXtouch landscape orientation Touchscreen User Interface - MAXtouch [Audio file name: audf_llm_sec_plane_olt_maxtouch.mp3] The MAXtouch is a color touchscreen user interface for control of multiple functions. The touchscreen corrects its display orientation from portrait to landscape, when the X-ray tube is tilted by 90°. Please note: Various functions of the MAXtouch are available as well on the Touchscreen User Interface (TUI) of the system remote control console. ? MAXtouch – Functions of Tube Movement Buttons You control the movements of the 3D overhead support by pressing the buttons on the handles of the X-ray unit. Select the colored callouts bellow to learn more about the functions of the tube movement buttons. Functions of Tube Movement Buttons [Audio file name: audf_llm_sec_plane_olt_tmb.mp3] You control the movements of the 3D overhead support by pressing the buttons on the handles of the X-ray unit. Select the colored callouts bellow to learn more about the functions of the tube movement buttons. Floating tube movement (longitudinal, transverse, vertical) Tube rotation about the horizontal axis Transverse tube movement Longitudinal tube movement Vertical tube movement down (motorized) Vertical tube movement up (motorized) Vertical tube movement up and down Tube rotation about the vertical axis You control the movements of the 3D overhead support by pressing the buttons on the handles of the X-ray unit. Select the colored callouts bellow to learn more about the functions of the tube movement buttons. MAXtouch Touchscreen User Interface (TUI) Using the MAXtouch on the 3D overhead tube in the examination room, you can see the most important system parameters, select the workplace and the organ program, and change acquisition parameters. Select the colored frames in the image to learn more about the MAXtouch touchscreen user interface (TUI). Round buttons start an action immediately. Square buttons toggle a function or open a popup menu Important message with confirmation MAXtouch Touchscreen User Interface (TUI) [Audio file name: audf_llm_sec_plane_olt_maxtouch_tui.mp3] Using the MAXtouch on the 3D overhead tube in the examination room, you can see the most important system parameters, select the workplace and the organ program, and change acquisition parameters. Select the colored frames in the image to learn more about the MAXtouch touchscreen user interface. Page wireless remote control (depends on system options) Switch between active detectors for free exposure (The icon depends on the selected detector) Help / Tool tips on / off Movement button indicators Movement button indicators System position information SID, collimation and grid status Select top alignment Store collimator settings System messages Workplace selection, tracking options, and patient position Tracking tube /detector on / off SID tracking on / off ? Exam set and organ program selection Patient data Generator subtask cards for parameter display and function selection MAXtouch TUI – Generator Tab Card Select the colored frames on the image to learn more about the Generator tab card of the MAXtouch touchscreen user interface. ? Generator Tab Card [Audio file name: audf_llm_sec_plane_olt_maxtouch_generator.mp3] Select the colored frames on the image to learn more about the Generator tab card of the MAXtouch touchscreen user interface. Restore original values Focus large / small Additional copper filter [millimeters] Increase exposure time (dose reduction) Measuring field(s) (dominant) Exposure correction in exposure points [EP] Dose level (sensitivity) Product of tube current and time in steps of 1 EP steps [milliampere seconds] Tube voltage in steps of 0.5 Exposure Points (EP) [kilo volts] MAXtouch TUI – Ortho Tab Card Select the colored frames in the image to learn more about the Ortho tab card of the MAXtouch touchscreen user interface (depends on the configuration sold). Ortho Tab Card [Audio file name: audf_llm_sec_plane_olt_maxtouch_ortho.mp3] Select the colored frames in the image to learn more about the Ortho tab card of the MAXtouch touchscreen user interface (depends on the configuration sold). Confirm the Ortho end position after you have angled the tube down. A check mark is displayed when the position has been confirmed. ? Confirm the Ortho start position after you have angled the tube up. A check mark is displayed when the position has been confirmed. Select TOD (Table-Object Distance) The TOD must be measured for every patient, either from the table top to the Region of Interest (ROI) or from the front of the ortho stand to the ROI. MAXtouch TUI – Setup Tab Card Select the colored frames on the image to learn more about the Setup tab card of the MAXtouch touchscreen user interface. Setup Tab Card [Audio file name: audf_llm_sec_plane_olt_maxtouch_setup.mp3] Select the colored frames on the image to learn more about the Setup tab card of the MAXtouch touchscreen user interface. Select stand movement speed Low speed and high sensitivity Moderate speed and sensitivity High speed and low sensitivity ? CAREPOSITION on / off (option) Block radiation Please note: We recommend using this button at all times, except when a procedure is in progress. This is to prevent the possibility of radiation being emitted by accidental / unintended activation of an exposure release button. Block system movement ? Collimator and Control Panel The collimator and its control panel consist of the following components: Manual vertical collimation Manual horizontal collimation Button for full-field light localizer and laser line light localizer Measuring tape for SID / SOD measurement The measuring tape has two scales: inch (left scale) and cm (right scale) Laser line light localizer with sliding cover The laser line light localizer projects the axis mark for longitudinal centering, which is aligned with the centering mark on the receptor. Its sliding cover is used to protect the eyes of the patient or any other person. Accessory rails The accessory rails may be loaded with a maximum of 70 N (7 kg / 15.4 lbs). Crosshairs in the light localizer window (1) (2) (3) (4) (5) (6) (7) (6) Collimator and Control Panel [Audio file name: audf_llm_sec_plane_olt_ccp.mp3] Please make yourself familiar with the single hardware components of the collimator and its control panel. ? Underside Collimator Control Elements – Laser Light The laser line light localizer is located at the underside of the collimator together with a sliding cover. To protect the eyes of the patient or any other person, the laser outlet (1) of the laser line light localizer can be closed with the sliding cover (1a). (1a) In addition, the locking spring is located on the left guide rail at the underside of the collimator. The locking spring locks the compensating filters, templates, etc., inserted in the accessory rails of the collimator, thus securing them against falling out. To remove the accessories, press the locking spring to the left until the compensating filter, template, etc., can be removed from the collimator. (1) (1a) Underside Collimator Control Elements - Laser Light [Audio file name: audf_llm_sec_plane_olt_ucce.mp3] The laser line light localizer is located at the underside of the collimator together with a sliding cover. To protect the eyes of the patient or any other person, the laser outlet (1) of the laser line light localizer can be closed with the sliding cover (1a). In addition, the locking spring is located on the left guide rail at the underside of the collimator. The locking spring locks the compensating filters, templates, etc., inserted in the accessory rails of the collimator, thus securing them against falling out. To remove the accessories, press the locking spring to the left until the compensating filter, template, etc., can be removed from the collimator. ? Collimator Settings Display on MAXtouch Looking at the icons displayed on the bottom of the MAXtouch, you can check the settings of the collimator (system position information). Select the colored callouts bellow to learn about which icon represents which collimator setting. Collimator Settings Display on MAXtouch [Audio file name: audf_llm_sec_plane_olt_csmt.mp3] Looking at the icons displayed on the bottom of the MAXtouch, you can check the settings of the collimator (system position information). Select the colored callouts bellow to learn about which icon represents which collimator setting. Collimator height in cm or inch Detector or CR cassette orientation: Landscape mode Portrait mode No detector or cassette available in the detector tray Collimator rotation Collimator mode: Manual, or ACSS (Automatic Collimation Size Selection) Collimator width in cm or inch Looking at the icons displayed on the bottom of the MAXtouch, you can check the settings of the collimator (system position information). Select the colored callouts bellow to learn about which icon represents which collimator setting. ? Course Review Congratulations. You have completed the LUMINOS Lotus Max Optional System Components – Second Plane X-Ray Unit Online Training. Select the numbered buttons below to review the material before proceeding to the final assessment. Understand components and functionalities of the colli-mator and its control panel Learn about the MAXtouch touchscreen user interface (TUI) on the tube Get to know the hardware components of the ceiling-suspended X-ray unit 1 1 2 2 2 3 3 3 Course Review [Audio file name: audf_llm_sec_plane_olt_cr.mp3] Congratulations. You have completed the LUMINOS Lotus Max Optional System Components – Second Plane X-Ray Unit Online Training. Select the numbered buttons below to review the material before proceeding to the final assessment. Components & Functionalities of Collimator and Control Panel Manual vertical collimation Manual horizontal collimation Button for full-field light localizer and laser line light localizer Measuring tape for SID / SOD measurement (inch – left scale, cm - right scale) Collimator underside (see also below): Laser line light localizer with sliding cover Accessory rails (maximum load of 70 N – 7 kg / 15.4 lbs) Collimator underside: Crosshairs in the light localizer window The laser line light localizer (5) is located at the underside of the collimator together with a sliding cover. To protect the eyes of the patient or any other person, the laser outlet (8) of the laser line light localizer can be closed with the sliding cover (8a). (1) (2) (3) (4) (5) (6) (7) (6) (8a) (8) MAXtouch Touchscreen User Interface (TUI) Generator subtask cards for parameter display and function selection Patient data Exam set and organ program selection Workplace selection, tracking options, and patient position System messages SID, collimation and grid status System position information Movement button indicators Help / Tool tips on / off Switch between active detectors for free exposure Page wireless remote control Hardware Components of the Ceiling-Suspended X-Ray Unit The ceiling-suspended 3D overhead support consists of the following components: Lifting column X-ray tube unit Touchscreen user interface (MAXtouch) Collimator Handles with buttons Use the handles, if you want to manually bring the tube unit into another position (vertical, longitudinal, transverse or rotation). Collimator control panel Disclaimer Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com ? Disclaimer Assessment This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course and earn your certificate. You may repeat the assessment as many times as needed. Start ? Assessment Select the best answer. ? Question 1 of 5 If I want to manually bring the tube unit into another position,… I use the handles fixed to both sides of the MAXtouch and press the corresponding button for the desired direction of the movement. I grab both sides of the X-ray tube unit to rotate it. I drive the lifting column down with its remote control. I grab the accessory rails and move the tube unit into the desired position. I grab the accessory rails and move the tube unit into the desired position. I grab the accessory rails and move the tube unit into the desired position. Multiple Choice Incorrect Do not grab the accessory rails to move the tube unit into position! Incorrect The lifting column is non-motorized and therefore doesn’t have a remote control. Incorrect Do not grab the X-ray tube unit to move it! It may be heated up. Incorrect Select the best answer. ? Question 2 of 5 Which statement about the collimator is correct? On its control panel, there are two separate knobs for manual vertical and horizontal collimation. Collimator settings get displayed on its left side. The collimator is an option to the ceiling-suspended X-ray tube unit. The collimator is an option to the ceiling-suspended X-ray tube unit. The collimator is an option to the ceiling-suspended X-ray tube unit. The button to turn on / off full-field light localizer and laser line light localizer is located on its underside. The button to turn on / off full-field light localizer and laser line light localizer is located on its underside. The button to turn on / off full-field light localizer and laser line light localizer is located on its underside. Multiple Choice Incorrect The button to turn on / off full-field light localizer and laser line light localizer is placed right in the middle of the collimator front. Incorrect The collimator is always part of the ceiling-suspended X-ray tube unit. Incorrect Collimator settings are dispalyed on the bottom of the MAXtouch. Incorrect Select the best answer. ? Question 3 of 5 Which statement about the underside of the collimator is correct? To protect the eyes of the patient, the laser outlet of the laser line light localizer can be closed with a sliding cover. The accessory rails may be loaded with a maximum of 10 kg / 22 lbs. The locking spring locks the current position of the collimator. The locking spring locks the current position of the collimator. The locking spring locks the current position of the collimator. The tape measure scales are displayed on the underside of the collimator. Multiple Choice Incorrect The tape measure scales are displayed at the collimator front. Incorrect The locking spring locks any accessories inserted in the accessory rails and secures them from falling out. Incorrect 7 kg / 15.4 lbs is the maximum load for the accessory rails. Incorrect Select the applicable image. ? On the MAXtouch, which kind of button starts an action immediately? Question 4 of 5 Pick One Incorrect This icon shows an important message with confirmation. Correct Incorrect Square buttons toggle a function or open a popup menu. Select three (3) answers. ? Question 5 of 5 Which of the following are located on the MAXtouch display? Setup tab card Generator tab card Generator tab card Generator tab card Ortho tab card Ortho tab card Ortho tab card Tools tab card Tools tab card Tools tab card Multiple Answer Incorrect One or more answers are incorrect. Correct Assessment Results YOUR SCORE: PASSING SCORE: Review Retry Retry Continue Continue Continue %Results.ScorePercent%% %Results.PassPercent%% ? Assessment Results You did not pass the course. Take time to review the assessment then select Retry to continue. Congratulations. You passed the course.. Exit To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. ? You have completed the LUMINOS Lotus Max Optional System Components – Second Plane X-Ray Unit Online Training. Completion Navigation Help Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Timeline Select the CC icon to display closed captioning (subtitles). Click Next to continue. Next Caption Icon add subtitles Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Tab Arrow Slide Select the X to close the pop-up. Click Next to continue. Next Layer Slide Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Assessment Slide Question Bank 1 HOOD05162003170117 | Effective Date: 30 MAR 2021 1.1 Welcome 1.2 Hints for Navigating 1.3 Optional System Components 1.4 Ceiling-Suspended X-Ray Unit 1.5 Touchscreen User Interface - MAXtouch 1.6 Functions of Tube Movement Buttons 1.7 MAXtouch Touchscreen User Interface (TUI) 1.8 Generator Tab Card 1.9 Ortho Tab Card 1.10 Setup Tab Card 1.11 Collimator and Control Panel 1.12 Underside Collimator Control Elements - Laser Light 1.13 Collimator Settings Display on MAXtouch 1.14 Course Review 1.15 Disclaimer 1.16 Assessment
- luminos
- lotus
- max
- radiography
- xray
- x-ray
- second
- 2nd
- plane
- vf11b