MAMMOMAT Revelation: How to Perform Implants
Step by step instructions on how to perform implants on the MAMMOMAT Revelation.
How to Perform Implants MAMMOMAT Revelation 1. Register your patient 2. Select the IMPLANT procedure from the “Open Patient” sub task card if it is not a populated procedure from your RIS Open patient Operator: AB EM Procedure: MPLANT PV sequence: Custom Display M.: Except mag/spot 3. The Acquisition mode in the Acquisition subtask card will automatically default to the IMPLANT, with the correct IPPG. Open patient Acquisition Acquisition mode: Implant IPPG: F1_Imp 4. Manual OpDose will automatically default for the exposure setting. ManualOp Decomp ..... Advanced 5. The technique will automatically be selected based on the patient breast thick- ness. 6. Perform the Implant in place images, and continue with the Implant displaced images. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date: XX/XX/XXXX | HOOD/HILS Job Aid | How to Perform Implants Effective Date: 02/19/2019 | HOOD05162002989662 Procedure IMPLANT imagos 7. Be sure that your icons are labeled correctly for the displaced views. Ex: ID view and also PRIME selections Procedure IMPLANT 8. The Acquisition Mode in the Acquisiton Tab will automatically default back to the correct IPPG for the displaced views. Acquisition Acquisition mode: Prime IPPG: F1_Gen2 9. Click OK. Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 3 Job Aid | How to Perform Implants Effective Date: 02/19/2019 | HOOD05162002989662 Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 3
- MAMMOMAT Revelation: How to Perform Implants