Mammomat Inspiration Hardware Overview Online Training - USA
This training introduces you to the system components of the Mammomat Inspiration.
Welcome to the Mammomat Inspiration Hardware Overview Online Training. This training will introduce you to the following system components: X-ray stand Acquisition workstation (AWS) Accessories Upon successful completion of this course, you will be able to: Identify the hardware components of the Mammomat Inspiration X-ray stand and the acquistion workstation (AWS) Perform emergency stops and emergency release procedures Use the single-touch function for angulation adjustment Identify the buttons on the control box and recognize the color-coding Recognize the information on the stand display Congratulations. You have completed the Mammomat Inspiration Hardware Overview Online Training. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Select the link below to view/print your review material before proceeding to the final quiz. Download and print a copy of the Course Review. Components of the X-Ray Stand Emergency STOP buttons Performance and consequences of the emergency STOP Recovery of the system Emergency release Step by step instruction for the performance of the emergency release Operation keys Height and angulation adjustment Single touch function Field light Flat-panel (FD) detector object table Size of the detector (24 x 30 cm) Calibration intervalls due to external influences Compression plates Utilization of compression plate depending on examination purpose Radiation field size depending on size of the compression plate Compression control knobs Manual compression and decompression Foot switch Height adjustment Compression and decompression Field light turns on, if compression pedal is activated Information on the stand display Projection angle Thickness of the compressed object Compression force in Newtons Patient name Blocked movements Face shields Prevents the patient's head from moving into the beam path Different face shields for standard examination, tomosynthesis and biopsy Components of the acquisition workstation (AWS) Control box System ON/OFF Emergency STOP button Decompression of the breast Radiation release The X-ray stand of the Mammomat Inspiration consists of the following parts: Swivel arm Collimator unit Face shield Compression unit Object table (detector) Patient support handles Stand display Foot switches Learn about the components of the X-ray stand. Learn about the components of the X-ray stand. Base ImageHotspotsText BlocksImage FileSwivel arm with X-ray tube unit and collimator (integrated)Compression unit with object table (detector)Patient support handles (on both sides)Emergency STOP button The emergency STOP buttons are located on both sides of the X-ray stand and on the control box at the acquisition workstation. Press the emergency STOP button if an emergency occurs, that implies danger for the patient, the system operator, or for the system. Consequences of engaging the emergency STOP button: all unit drives will be switched off and all movements as well as radiation will be interrupted. decompression is not performed automatically. To release the patient you must decompress the breast manually by performing the emergency release. Recovery of the system: when you have clearly detected the cause of danger and rectified it you can reset the emergency STOP button by turning it clockwise. after you release the emergency STOP button, error messages might be displayed on the screen. Please confirm them and proceed. Learn how to perform an emergency release. Learn how to perform an emergency release. Checklist TitleChecklist TypeChecklist ContentStep 1HTML Forcefully press the emergency release button (1) with one hand, and keep the button pressed. It is located on the top of compression unit. Step 2HTML Place the other hand under the compression plate (2) and press it upward. The patient can be removed from the system. Step 3HTML First remove the hand from the emergency release button, and then remove the hand from the compression plate. Ensure the compression plate does not fall on the detector. Step 4HTML The system is automatically reset upon pressing the emergency release button. Confirm the error message on the AWS monitor. The operation keys are located on both sides of the swivel arm and the compression unit. Their function is identical. Use the operation keys for height adjustment and angulation adjustment. Single touch button: press briefly to move the swivel arm to the preset angle position for the next projection view. press the button slightly longer to transfer the adapted angulation to the opposite site. Field light button: press the field light button to turn the field light on. the field light will turn on automatically when you activate the compression pedal of the foot switch. Learn about the operation keys. Learn about the operation keys. The face shield prevents the patient's head from moving into the beam path. Use the face shield appropriate to the examination. face shield for standard examination face shield for tomosynthesis face shield for biopsy The compression plate is mounted in front of the compression unit. The plastic trays can be removed from the holder to simplify cleaning. There are different compression plates available for different examination purposes. Use the compression plate appropriate to the examination. Please note: the collimator automatically adjusts the radiation field size to the size of the compression plate. select the size of the compression plate as small as possible for optimum exposure and lowest possible radiation exposure. Learn how to mount/remove the compression plate. Learn how to mount and remove the compression plate. The compression control knobs are located on both sides of the compression unit. Compression and decompression are driven by a motor. You can adjust the compression and decompression of the breast manually with the control knobs: turn the knob downward to compress the breast manually. turn the knob upward to decompress the breast manually. You can perform the following actions with the two mirror-inverted foot switches: control motorized compression and decompression. adjust the height of the swivel arm. Recommendation for the placement of the foot switches: place one foot switch on each side of the X-ray stand. position the foot switches so that the pedals for compression point to the center in each case. Learn how to operate the foot switches. Learn how to operate the foot switches. Base ImageHotspotsText BlocksImage FileLower swivel arm (height adjustment)Raise swivel arm (height adjustment)Raise compression plate (decompression) Object illumination switches on automatically when the foot switch pedal is activated.Lower compression plate (compression) Object illumination switches on automatically when the foot switch pedal is activated. The stand display is located at the base of the X-ray stand. It provides the following information: Current projection angle Thickness of the compressed object Current compression force expressed in Newtons Patient name Please note: the (P) next to the compression force shows that all table movements (height and rotation adjustment) are blocked due to a compression force of 30 N or more. Learn about the information on the stand display. Learn about the information on the stand display. Base ImageHotspotsText BlocksImage FileCurrent angle of the swivel arm in [°].Thickness of the compressed object in [mm].Compression force expressed in [N]. The actual compression force is displayed during compression. When using OPCOMP: The force indicator flashes, when optimum compression is attained.Patient nameBlocked movements: As soon as (P) is displayed, all table movements are blocked. The rotation and height adjustment are always blocked when the compression force is around 30 N or more. The control box is part of the acquisition workstation (AWS). You can perform the following actions with the control box: System ON and System OFF Emergency STOP Decompression of the breast Release radiation Learn about the control box. Learn about the control box. Base ImageHotspotsText BlocksImage FileDecompression: Raise compression plate.Emergency STOP button: All system movements and X-ray radiation are stopped.Exposure button: Press to start radiation.System ON. When the system is ready for operation, the button lights up green.System OFF. Color coding of the exposure button. Learn about the color coding of the exposure button. The button flashes green when the system is ready. The button lights up solid green when the system is ready for exposure. The button lights up yellow during irradiation. Learn about the accessories for radiation release. Learn about the accessories for radiation release. Tab TitleTextHand switch In addition to the radiation release at the control box, you can also use the hand switch (option). The hand switch is plugged into the control box. Press the button to release the exposure and hold it down until the acoustic signal ends. Please note: The operating staff always must be located behind the radiation shield when releasing radiation with the hand switch. Foot switch You can also release radiation with the foot switch (option). The foot switch is plugged into the control box. Press the foot switch pedal for radiation relase and keep it pressed during the exposure. Please note: Operating staff must be located behind the radiation shield when releasing radiation with the foot switch. The flat-panel detector (FD) object table is located in the front of the compression unit. The detector in the object table is 24 x 30 cm. Please note: external influences as temperature fluctuations, humidity, or vibrations can change the settings of the detector. Therefore, you should calibrate the detector every three months if the constant room temperature deviates by more than 7°C from the temperature at the last calibration Learn about the magnification table. Learn about the magnification table. The magnification tables (options) are used for magnification exposures. They are available for the factors 1.5 and 1.8. The system automatically recognizes whether a magnification table is installed or not. Please note: The face shield must be removed when using the magnification table, except when using the spot compression plate. Use a compression plate appropriate to the examination, for example the magnification compression plate 16 x 20 cm. Only one factor (either 1.5 or 1.8) can be active on the system. The acquisition workstation (AWS) consists of the following components: Workstation with CD-R/DVD-R drive TFT monitor Control box Mouse Keyboard (on keyboard shelf) Operation console (option) with radiation shield (option) Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Functionalities described in the material or parts of this functionality may not yet be released for customers and not yet be commercially available in every country. Due to regulatory requirements, the future availability of said functionalities or parts thereof in any specific country is not guaranteed. Please contact your local Siemens sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH
- Women's health
- breast
- screening
- Mamomat
- Mammography