MAMMOMAT Inspiration Stereotactic Biopsy: How to Change View Mid Exam
MAMMOMAT Inspiration Stereotactic Biopsy: How to Change View Mid Exam step by step
MAMMOMAT Inspiration Stereotactic Biopsy: How to Change View Mid Exam Women’s Health/Mammography 1. Release Compression. 2. Click "Cancel" on the pop up. WH AWS X The compression force is below 15N ! Please be aware that the accuracy of the targeting can no longer be guaranteed, due to possible movement of the breast as a result of insufficient compression force. Click "Ok" to continue the examination. Click "Cancel" to start with a new scout view. OK Cancel 3. Right-click on image in image gallery. 4. Click "Add" to add an image. Image Attributes ... Repeat ... Correct ... Reprocess ... Add 5. Select “Add” to acquire remaining images. SIEMENS siemens.com/healthineers Healthineers Job Aid | MAMMOMAT Inspiration Stereotactic Biopsy: How to Change View Mid Exam Effective Date: 8/19/2016 | 475 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2 © Siemens Healthcare GmbH, 2017
- Stereotactic Biopsy