PEPconnect

MAX System FLC: Common System Acronyms and System Messages

This step by step is designed to help the User understand common system
acronyms and system messages. Additionally there are suggestions for how to move past the system message.

MAX System FLC: Common acronyms and system messages Common acronyms FLC Fluorospot compact, the operating system of the computer FD Flat detector DIT Digital imaging tower BWS Bucky wall stand Wi‐D Wireless mobile detector for use with patient table, bucky wall stand, and free examinations OGP Organ program‐ a set of parameters for an acquisition. T Table Bucky Acquisition W Wall Bucky Acquisition X Tabletop or Free Exposure FL Fluoroscopy SIEMENS siemens.com/healthineers Healthineers Job Aid Effective Date: 11/07/2017 | Quality HOOD05162002714139 Common system messages FD for Free Mode is in a tray Current acquisition mode is set for free (X). Remove it or attach another FD to OK free mode Take Wi-D out of either wall or table bucky tray. i Insert wi-D in table |2/2| Current acquisition mode is set for table, but Wi-D is not in the table bucky tray. i Align tube / BWS-FD Tube is not aligned to bucky wall stand, check detents. i Align tube / table FD Tube is not aligned to table, check detents. No table tilt Move DIT (FD) towards The DIT is at the extreme end of the table, center of table in longitudinal OK move the DIT to the center of the table to direction allow for full table tilt. Movement blocked - overhead tube OK Park overhead tube or press and hold park not in parking position override button to allow for movement. Risk of collision with FD (DIT) - OK Collision sensors on side of DIT are activated, Direction of movement disabled. move object. FLC will now switch to acqu. mode Disengage radiation switch and OK An exposure was attempted when the Examination tab was not selected. Pressing the press again acquisition button will select the examination tab. A second press will take the exposure. i Raise table to working height. No X-ray. Table at min No DIT (FD) movement - Tube touches the floor. Raise table first OK i FD in parking position |2/2] DIT is not fully un-parked. Make certain a solid green light appears on parking button. Auto-centering not possible. Align Tube cannot align to the table bucky tray, it is tube to FD and FD to tube OK beyond the range. Move tube within range in order to align to the table bucky and activate tube to FD tracking. Wait at least 2s between acquisitions OK Acquisition button is being presses before the last acquisition is fully processed. Wait until last acquisition appears on screen. Radiation aborted. Switch Radiation button is being toggled off and on disengaged too early or system OK too rapidly. error occurred Green LED lights flashing indicate the DIT is P not parked or un-parked. Place the DIT in a fully parked or un-parked position. Siemens Healthineers Services Page 2 of 3 Disclaimers*:Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2017