MAX Systems: Using MAXalign
MAX Systems: Using MAXalign Step by Step
MAX System: Using MAXalign Radiography MAXalign is a tool that can be utilized while performing “Free Exposures.” This tool assists the user with proper angulation of the X-Ray tube by displaying the current wireless detector angle on the MAXtouch screen. Note: The angle degree of the detector while in “Portrait” position is represented by the icon on the left. When in “Landscape” position the icon on the right will display the angle degree. When the detector is not flat in either plane a “side to side” or “top to bottom” degree of angle may be displayed. 1. Open the desired patient in the Examination tab on the FLC. 2. Select an “X” Organ Program (for free exposure). 3. On the MAXtouch screen located on the front of the X-Ray tube, select the “Device Position” tab. Tape Device Measure Position 5ª Generator Setup 'o 0 164cm 48ª 4. Position the wireless detector under the patient/X-Ray tube. After a few seconds the angle of the wireless detector will appear on the MAXtouch screen. Note: The system can read angles of detector tilt from zero to eighty-nine degrees only. SIEMENS siemens.com/healthineers Healthineers Job Aid | MAX Systems: Using Maxalign Effective Date: 06/02/2017 | HOOD05162002609401 5. Rotate the X-Ray tube until the angle corresponds to the displayed wireless detector angle. OOOO 00 O 8 100 -430 OOOO Position Siemens Healthineers Services Page 2 of 3 © Siemens Healthcare GmbH, 2017 Job Aid | MAX Systems: Using Maxalign Effective Date: 06/02/2017 | HOOD05162002609401 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3 © Siemens Healthcare GmbH, 2017
- MAX systems: Using MAXalign