Mean Curve Evaluation (B-line and E-line)
Job aid for post processing using the Mean Curve Evaluation
Mean Curve Evaluation (B-line and E-line) syngo MR Systems with B-line and E-line Software Mean Curve can be used to evaluate contrast uptake in dynamic scanning, as well as other dynamic applications 1. Load Series into Mean Curve Task Card a. Open Patient Browser b. From the Local Database select your series (e.g. dynamic, pre- and post-contrast, TI scout, etc.) i. Hold Ctrl + Left Click on each series if separate (not needed if single dy- namic series) ii. Note: Subtraction series can be also be loaded if desired c. Select Main Menu > Applications > Mean Curve Patient Applications Transfer Edit View Filter Evaluation Sort Options Help Report Open Tissue Report Tools 40 Mosaic ? 3D TRICOTW TTTTT Argus [3] tirm_tra BreVis ₹/com/ //11 / BOLD [4] t1_f13d_tra_nonfatsat R/com/ 1/11 / BOLD Evaluation Soft Tissue (MR) [5] t1_f13d_tra_dynaVIEWS_spa Ricom/ 11/1 1 Composing [6] Care Bolus Mean Curve R/com/// // / Perfusion (MR) [7] t1_f13d_tra_dynaVIEWS_spa Spectroscopy R/com/ 1/11 / Neuro 3D (MR) [8] t1_f13d_tra_dynaVIEWS_spai R/com/ // // / Tissue 4D (MR) Vessel View [9] t1_f13d_tra_dynaVIEWS_spai R/com/ //11 / Study Split [10] t1_f13d_tra_dynaVIEWS_sp: R/com/ / 111 1 DICOM Tools SIM Breast [11] t1_f13d_tra_dynaVIEWS_sp R/com/ 1111 1 S Desktop TimCT abdomen [12] t1_f13d_tra_dynaVIEWS_spi | R/com/ / /11 / Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Job Aid | Mean Curve Evaluation (B-line & E-line) Effective Date: 06/19/2020 | HOOD05162003094576 2. Processing in Mean Curve a. A new tab will open that contains the selected series b. Scroll through image to find area-of-interest and best time-point (series) i. Use the shortcut buttons on your keyboard or Scroll tab tools in Mean Curve Scrolling Tools Scroll Series +/- +0 Scrolling Image +/- + 0 c. Drawing an ROI i. Select ROI tool (e.g. circle, rectangle, freehand) Tools Scroll ii. Draw ROI over area of interest 1. Note: Can draw more than one ROI (4 ROI Maximum) SIM A MRC1 SIM 3/31/1974, M, 55Y Skyra MR D13 STUDY 1 1/4/2012 ALPH 9:33:22 AM 15 IMA 55 / 112 R 10 cm MF 1.00 TR 4.5 TE 1.6 TA 01:29 TP H15 BWV 385,0 SP H12.3 p3 M/DIS20 SL 1 611 FoV 390*390 LA1/PFP/SES 426p*448 7BL;7BR; AXL; AXR Tra W 190 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 *#3d1 /10 66 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 2 of 5 Job Aid | Mean Curve Evaluation (B-line & E-line) Effective Date: 06/19/2020 | HOOD05162003094576 d. Select Start Evaluation tool to begin processing Start Evaluation 3. Evaluating Results a. The Resulting diagram will display in the Upper Right Segment and shows a curve in the color and line style of the corresponding ROIs b. To see generated table, use Dog Ears in top right corner of graph segment Mamma1 Result mage 1 Mamms1. Result Table 1 Mean Curve across (3 ima 27 - 9 ima 27, rel 3 ima 27] dif Mean Curve across (3 ima 27 - 9 ima 27; rel 3 ima 27) diff Scaling Factor = 1.0 Offset = 00 SPAT1.3 Scaling Factor = 1.0 Offset = D.O Average of mean values: 65 00 -5.19 Averane of alco5: 0.50 0.09 Series Rol 1 ROI 2 RCI 3 ROI 4 Average of max. values: 241.00 219.1 NO. Series No. vean SDev Area SDeY Area Mean SDev | Area Mean SDev Area --- NON Moon 05.6 - - 14.1 96.0- 10.0 31.1 0.5 0.0 75 0.7 39.3 44.6 05 _5.6 77 0.7 76.0 79.5 0.5 -3.0 8.1 0.7 95.6 90.9 -14.1 9.5 0.7 72.8 46.8 0.5 -1.7] 7.7 0.7 73.5 46.5 05 -5.0 89 0.7 97.8 54.6 0.5 TO 13.0 0.7 41.5 O.D 15.0- Scris No. 1 of 1 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 3 of 5 Job Aid | Mean Curve Evaluation (B-line & E-line) Effective Date: 06/19/2020 | HOOD05162003094576 c. Additional Tools: i. To smooth the curve slect the icon in the Tools subtask card 1. Result tables are not affected › ii. To change the scaling/sorting select the icon in the Tools subtask card 1. Note: May be necessary to change scaling in some instances (e.g. trigger time for TI Scout or Native Space) Scaling X X-AXIS y-AXIS Sort Minimum 7 Maximum 11 Axis Label o Ser / Ima No O Trigger Time O Echo Time O Slice Pos. O Normal Time automatic Scaling OK Cancel Help 4. Saving Results a. To save images with ROIs and the result data, select Save Evaluation As Save Evaluation As Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 4 of 5 Job Aid | Mean Curve Evaluation (B-line & E-line) Effective Date: 06/19/2020 | HOOD05162003094576 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 5 of 5
- Mean Curve Evaluation (B-line and E-line)