Mean Curve of MR Neurology Workflow Job Aid
Mean Curve of MR Neurology Workflow Job Aid
Mean Curve of MR Neurology Workflow Job Aid syngo.via MR An evaluation with Mean Curve provides information about signal changes as a function of time and place. With Mean Curve evaluation, you can analyze the contrast medium uptake in the tissue. 1. Select > Mean Curve icon in the Case Navigator MR Neurology Reading 2. A new image layout opens. Select a desired image, from the upper right corner menu, select MCEval Ellipse ROI or MCEval Freehand ROI. Note: You can draw ROIs in all segments, each ROI is displayed in all other segments. AHR Distance Line MR_Neurology ROI Circle Q ... CURRENT Pixel Lens 1000-300 Marker IT row Angle VOI Freshand Text T RFA Spine Rib Label O TR 8720 D TP H14 TE 540 ENTHOD BL 5 MPR THICK CCHIO NORM 102"12 HEAHEF 78 60 3000 / 100 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date: 08/14/2019 | HOOD05162003026833 Mean Curve of MR Neurology Workflow Job Aid Effective Date08/14/2019 | HOOD05162003026833 3. If required, select another series from the Selected 4D series list in the lower right segment. You can set a Mirror line and mirror the drawn ROI to compare the signal time course of the suspect tissue with normal tissue. a. Select > Show Lines Icon. If required, adjust the midline to the correct position b. Select > Mirror ROIs Icon. Each ROI is displayed on the opposite sides of the mirror line and is indicated by a white contour. Each mirrored ROI can be adjusted individually without affecting the original ROI. C Show Mirror ROIs 4. Select > Save Finding button to add a snapshot of all segments and the signal time courses to the finding. Note: If you modify a measurement afterwards, the Save Finding button changes into the Update Finding button. Use this button to update the existing finding with the updated measurement. To create a new finding, you will need to close and reopen the mean curve tool. CSy Show Export lo Lines Selected 4D Series: Current. MR. ep2d_perfusion_FB3_MoC.latest Save Finding Close 5. Select > Close button to exit the mean curve evaluation and to close the mean curve layout. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 3 Mean Curve of MR Neurology Workflow Job Aid Effective Date08/14/2019 | HOOD05162003026833 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein‐ after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84‐0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 3
- Mean Curve of MR Neurology Workflow Job Aid