PEPconnect

Measurement Shortcuts syngo MR XA

Measurement Shortcuts syngo MR XA

Measurement syngo MR XA This Job Aid provides an overview of shortcuts available during the measurement. Program control Tab Go to the next button or program step within the queue. Shift + Tab Go to the previous button ot program step within the queue. Up Arrow/Down Arrow/ Select the previous or next program step within the queue. Ctrl + Spacebar Toggle the selection. Page Up/Page Down Selection side up/down. Up Arrow Preselect the previous or next program step within the queue. Down Arrow Shift + Up Arrow Select the previous or next program steps consecutively upward Shift + Down Arrow or downward within the queue. Home/End Select the first or last program step within the queue. Shift + Del Remove all queue entries (Clear All, only possible if queue is not running). F3 Stop. F12 Start next measurement (Continue). Depending on workflow status or active dialogs, Continue may apply to multiple functions simultaneously. In this case Continue is automatically assigned to the function with the highest priority:  Close the Exam Paused dialog box during measuremnts with/without contrast agent and perform the next meas- urement (Continue of the program scheduler) Ctrl + C Copy program step. Ctrl + X Cut program step. Ctrl + V Paste program step. Ctrl + S Save program or protocols (Save As). Ctrl + Insert Append a measurement pause to the end of the queue (Append Pause). Alt + Up Arrow Move the selected step up or down within the queue (Move Up, Alt + Down Arrow Move Down). Alt + Return Open the Step Properties dialog box for the selected step (Properties). Crtl + Shift + F3 Start measurement of the opened protocol step (Scan). Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Measurement shortcuts Effective Date: 05/13/2019 | HOOD05162003011876 SIEMENS Healthineers Measurement shortcuts | syngo MR XA Effective Date: 05/13/2019 | HOOD05162003011876 lanning segments in the GSP Ctrl + A Select all planning segments. Ctrl + B Shift to image plane. Ctrl + G Switch Group Graphics on/off. Ctrl + T Change between individual sub-steps in a Set-n-Go protocol. Ctrl + 1 Rotate selected object so that it is oriented perpendicular ot the reference plane (Perpendicular). Ctrl + 2 Shift the centers of all slice and slab groups into the defined ref- erence image plane (Shift to image plane). Ctrl + 3 Shift the selected slice or slab group against or in slice-selection Ctrl + 4 direction (Stack-, Stack+) Ctrl + 7 Shift the selected slice or slab group in Z direction (FoV-, FoV+). Ctrl + 8 Up Arrow/Down Arrow Scroll to previous or next slice according to display order. Left Arrow/Right Arrow Display previous or next series in the reference segment if such a series exists. When the first (last) loaded series is reached, the last (first) loaded series is displayed (Series+, Series-). Page Up/Page Down Scroll a predefined number of images up or down, according to display order. Home/End Go to initial or last document in stack. Spacebar Start, stop, continue playback of the movie. T Show or hide image text. H Show or hide reference lines. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 2 of 4 Measurement shortcuts | syngo MR XA Effective Date: 05/13/2019 | HOOD05162003011876 Parameter cards Ctrl + Right Arrow Go to the next parameter card. Ctrl + Left Arrow Go to the previous parameter card. Ctrl + Shift + Right Arrow Go to the next parameter subtask card. Ctrl + Shift + Left Arrow Go to the previous subtask card. Tab Go to the next parameter. Shift + Tab Go to the previous parameter. Up Arrow Increase numerical value. Down Arrow Decrease numerical value. Return or Tab (go to the Accept numerical value. next parameter) Up Arrow/Right Arrow Scroll to next parameter in the parameters set. Down Arrow/Left Arrow Scroll to previous parameter in the parameter set. Return or Spacebar Select/clear check box. Return Expand/collapse selection list. Arrow keys Select entry from selection list. or Home to first input or End to the last input Return or Esc Apply entry from selection list. or Tab (go to the next pa- rameter) Return or Spacebar Select button (for example, for coil selection). Inline Display Return or Spacebar Apply function of the icon with focus. F12 Start next measurement (Continue) Depending on workflow status or active dialogs, Continue may apply to multiple functions simultaneously. In this case Continue is automatically assigned to the function with the highest priority:  Start the breath-hold measurement (Scan Breathhold function of the Inline Display)  End the current measurement and start the next one in the queue (Stop & Continue function of the Inline Dis- play) Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 3 of 4 Measurement shortcuts | syngo MR XA Effective Date: 05/13/2019 | HOOD05162003011876 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the soft- ware and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Func- tionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales rep- resentative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and exam- ples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 4 of 4