This Job Aid reviews Camtasia workflow to record and save Viewing, post-processing and examination workflow.

MR Camtasia – Eline Job Aid MR Camtasia – Numaris X Camtasia is a software tool that allows you to record and save desktop activities. Create step-by- steps on MR workflow (e.g., post-processing workflow, examination workflow, etc.) Camtasia Software Tool 1. Select Applications > Desktop Applications Transfer Edit Queue Protocol View Image Tools a. Select Camtasia Studio 3D b. Select Camtasia Recorder Argus BreVis BOLD Composing Mean Curve Perfusion (MR) Spectroscopy Neuro 3D (MR) Tissue 4D (MR) Vessel View Desktop Common Camtasia Studio Camtasia Recorder Camtasia Player Camtasia Producer 2. Camtasia Recorder Window a. Select Tools > Options B Camtasia Recorder Capture View Effects Tools Help Camtasia Studio Camtasia Producer Camtasia Effects Camtasia MenuMaker TechSmith Camtasia Player Camta Theater for Camtasia Studio Converter for Camtasia Studio Options View or change program settings Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/09/2021 | HOOD05162003196019 Healthineers Job Aid | MR Camtasia – Eline Effective Date: 06/09/2021 | HOOD05162003196019 3. Tools Options Window Tools Options X a. Select Program Tab Hotkeys| Live Program i. Select Minimize before starting AVI File capture - Capture Options • Camtasia tool minimizes so Minimize before starting capture doesnt interfere with Pause before starting capture during the video capture Boost priority during capture Hide capture rectangle Solid capture rectangle Play movie after saving file Play AVI files with Camtasia Player Report dropped frames Always on top Bound frame size to a 4 pixel boundary Disable display acceleration during capture Capture layered windows Single frame capture Quick capture M Enable tips OK Cancel Help b. Select Hotkeys Tab i. Define Record/Pause hotkey Tools Options X ii. Define Stop hotkey AVI File Hotkeys|Live Program iii. Note: select any number of key Record/Pause hotkey combinations to Start/Stop CTRL SHIFT ALT recording F9 Stop hotkey CTRL SHIFT ALT + + F10 ScreenDraw hotkey CTRL SHIFT ALT None Advanced .. OK Cancel Help Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/09/2021 | HOOD05162003196019 Healthineers Page 2 of 6 Job Aid | MR Camtasia – Eline Effective Date: 06/09/2021 | HOOD05162003196019 c. Select File Tab i. Output File Name • Select Ask for File Name –enter video name ii. Output Folder – default (C:\Medcom\temp\CDR_OFFLINE\) iii. Temporary File Folder • Select C:\Medcom\temp\CDR_OFFLINE\ • Click on Folder – select destination (e.g., USB, External Hard drive) d. Select OK Tools Options X AVI File Hotkeys| Live Program Output File Name Ask for File Name Fixed File Name Name: Automatic File Name Prefix: |video Output Folder: C:\Medcom\temp\CDR_OFFLINE\ Temporary File Folder C:\MedCom\temp\CDR_OFFLINE OK Cancel Help 4. Camtasia Recorder Window Camtasia Recorder a. Select Effects > Cursor – define Capture View | Effects Tools Help how cursor is visualized during Annotation Camtasia recording Audio i. Select Highlight clicks Cursor Hide Cursor ii. Optional Cursor Effects Zoom & Pan Show Cursor selections are User TechSmi Options. Highlight Clicks – Preference Carasia Highlight Cursor • Highlight Cursor Recorder Highlight Cursor & Clicks • Highlight Cursor & Clicks Highlight mouse clicks in the capture ............... Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/09/2021 | HOOD05162003196019 Healthineers Page 3 of 6 Job Aid | MR Camtasia – Eline Effective Date: 06/09/2021 | HOOD05162003196019 b. Select Effects > Options i. Highlight Cursor • Select Color • Translucent, Semi-translucent, or Opaque – Select One • Note: selections are User Preference ii. Highlight Mouse Clicks • Left – Select Shape & Color • Right – Select Shape & Color • Note: selections are User Preference iii. Select OK Effects Options X Camtasia Recorder Annotation | Audio Cursor ScreenDraw | Watermark | Zoom Capture View Effects Tools Help Cursor Annotation Cursor Setup .. Audio Cursor Highlight Cursor Zoom & Pan Shape: Circle Color ... ABC TechSmi Size: Options. Carlasia Half scale @ Translucent @ Semi-translucent @ Opaque Recorder Highlight Mouse Clicks Left Shape: Rings Color ... Size: O Right Shape: Rings Color ... View or change effects settings Size: OK Cancel Help 5. Camtasia Recorder Window Camtasia Recorder a. Select Capture > Input i. Select Screen Capture View Effects Tools Help Record ? Pause Stop Delete Input Screen Output Window Region Fixed Region ... Capture entire desktop Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/09/2021 | HOOD05162003196019 Healthineers Page 4 of 6 Job Aid | MR Camtasia – Eline Effective Date: 06/09/2021 | HOOD05162003196019 6. Camtasia Player – replay Camtasia recording created a. Select Applications > Desktop > Camtasia Studio i. Select Camtasia Player ii. Select File > Open Applications Transfer Edit Queue Protocol View Image Tools D Camtasia Player 3D File Play Help Argus BreVis Open ... Ctrl+O BOLD Composing Close Mean Curve Exi Perfusion (MR) Spectroscopy TechSmith Neuro 3D (MR) Camtasia® Tissue 4D (MR) Vessel View Player Desktop Common Camtasia Studio Camtasia Recorder Camtasia Player Camtasia Producer Open a movie file b. Select Look in: C:\Medcom\temp i. Select CDR_OFFLINE folder • File Name > left-click Video File (e.g., Registration Workflow) • Select Open – Recording created plays • Note: all Camtasia Videos are store in this folder by default DI Open AVI File X Look jn: CDR_OFFLINE Iten type: AVI File MR_NewDat ... MR+VE11A -... Registrati Size: 634 KB Workflow.] Length: 00:00:36 File name: Registration Workflow.avi Open Files of type: AVI Files (".avi) Cancel Note: Camtasia continues to run in the background until user stops recording Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/09/2021 | HOOD05162003196019 Healthineers Page 5 of 6 Job Aid | MR Camtasia – Eline Effective Date: 06/09/2021 | HOOD05162003196019 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/09/2021 | HOOD05162003196019 Healthineers Page 6 of 6