PEPconnect

MR Camtasia - Numaris X

This Job Aid reviews Camtasia workflow to record and save Viewing, post-processing and examination workflow.

MR Camtasia – Numaris X Job Aid MR Camtasia – Numaris X Camtasia is a software tool that allows you to record and save desktop activities. Create step-by- steps on MR workflow (e.g., post-processing workflow, examination workflow, etc.) Camtasia Software Tool 1. Select Screen Recorder Icon 2. Select Camtasia Recorder Camtasia Recorder Camtasia Player Take Screenshot 3. Screen Capture Target Window a. Target i. Local Video Directory – saves recording to default “Screen Capture folder” ii. Click Dropdown – save recording to alternate file folder (e.g., USB, external hard drive) b. Select OK Screen Capture Target x Please select a target for your screen captures. Target: Local Video Directory OK Cancel SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 06/07/2021 | HOOD05162003195185 Job Aid | MR Camtasia – Numaris X Effective Date: 06/07/2021 | HOOD05162003195185 4. Camtasia Recorder Window a. Select Tools > Options Camtasia Recor ... - X Capture View Effects Tools Help Camtasia Studio Camtasia Producer Camtasia Effects Camtasia MenuMaker TechSmith Camtasia Player Cam Theater for Camtasia Studio Converter for Camtasia Studio Options ... 5. Tools Options Window a. Select Program Tab i. Select Minimize before starting capture • Camtasia tool minimizes so doesnt interfere with during the video capture Tools Options × AVI File Hotkeys| Live Program Capture Options Minimize before starting capture Pause before starting capture Boost priority during capture Hide capture rectangle Solid capture rectangle Play movie after saving file Play AVI files with Camtasia Player Report dropped frames Always on top Round frame size to a 4 pixel boundary Disable display acceleration during capture Capture layered windows Single frame capture Quick capture Enable tips OK Cancel Help Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2021 | HOOD05162003195185 Healthineers Page 2 of 7 Job Aid | MR Camtasia – Numaris X Effective Date: 06/07/2021 | HOOD05162003195185 Tools Options X AVI File Hotkeys Live Program b. Select Hotkeys Tab Record/Pause hotkey i. Define Record/Pause hotkey ii. Define Stop hotkey CTRL SHIFT + + + F9 iii. Note: select any number of key combinations to Start/Stop Stop hotkey recording F10 Screen Draw hotkey None Advanced .. c. Select File Tab OK Cancel Help i. Output File Name • Select Ask for File Name –enter video name ii. Output Folder – default iii. Temporary File Folder • Default (C:\ProgramData\Siemens\Numaris\MriSiteData\ScreenCap- ture\Videos\) • Click on Folder – select destination (e.g., USB, External Hard drive) d. Select OK Tools Options X AVI File Hotkeys | Live | Program | Output File Name Ask for File Name Fixed File Name Name: Capture C Automatic File Name Prefix: Capture Output Folder: C:\ProgramData \Siemens \Numaris \Mri Site Data\ Temporary File Folder mens \Numaris\MriSite Data \ScreenCapture \Videos OK Cancel Help Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2021 | HOOD05162003195185 Healthineers Page 3 of 7 Job Aid | MR Camtasia – Numaris X Effective Date: 06/07/2021 | HOOD05162003195185 6. Camtasia Recorder Window Camtasia Recor ... a. Select Effects > Cursor – define X how cursor is visualized during Capture View Effects Tools Help Annotation Camtasia recording Audio i. Select Highlight clicks Cursor Hide Cursor ii. Optional Cursor Effects – Zoom & Pan Show Cursor selections are User Prefer- TechSmit Options ... Highlight Clicks ence Camtasia Highlight Cursor Highlight Cursor & Clicks • Highlight Cursor Recorder) • Highlight Cursor & Clicks Highlight mouse clicks in the capture b. Select Effects > Options i. Highlight Cursor • Select Color • Translucent, Semi-translucent, or Opaque – Select One • Note: selections are User Preference ii. Highlight Mouse Clicks • Left – Select Shape & Color • Right – Select Shape & Color • Note: selections are User Preference iii. Select OK Effects Options Annotation | Audio Cursor Screen Draw | Watermark | Zoom Cursor Cursor Setup ... Highlight Cursor Shape Circle Color ... ABC Size: Half scale Translucent ( Semi-translucent @ Opaque Highlight Mouse Clicks Left O Shape: Rings Color ... Size: Right Shape: Rings Color ... O Size: OK Cancel Help Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2021 | HOOD05162003195185 Healthineers Page 4 of 7 Job Aid | MR Camtasia – Numaris X Effective Date: 06/07/2021 | HOOD05162003195185 7. Play Camtasia Recording – replay recording created a. Select Screen Recorder Icon b. Select Camtasia Player Camtasia Recorder Camtasia Player Take Screenshot []Camtasia Player X c. Select File > Open File Play Help Open ... Ctrl+C Close Exit TechSmith Camtasia" Player Open a movie file d. Select Look in: K:\ i. Select Camtasia Studio folder > Open • Note: all Camtasia Videos are store in this folder by default Open AVI File × Look in: Name A Date modified Camtasia Studio 5/17/2021 5:45 PM CustomerSeq 3/3/2021 12:47 PM CustomerSeqParamCardConfig 3/3/2021 12:47 PM DicomExport 3/3/2021 12:47 PM DICOMTestImages 3/3/2021 12:47 PM File name: Open Files of type: AVI Files (" avi) Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2021 | HOOD05162003195185 Healthineers Page 5 of 7 Job Aid | MR Camtasia – Numaris X Effective Date: 06/07/2021 | HOOD05162003195185 ii. Select Video > Open - Recording created plays Open AVI File × Look in: Camtasia Studio AVI Patient Registration File name: Patient Registration Open Files of type: AVI Files (" .avi) Cancel Note: Camtasia continues to run in the background until user stops recording Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2021 | HOOD05162003195185 Healthineers Page 6 of 7 Job Aid | MR Camtasia – Numaris X Effective Date: 06/07/2021 | HOOD05162003195185 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/07/2021 | HOOD05162003195185 Healthineers Page 7 of 7