MR Cardiac Analysis Volume Quant Job Aid

MR Cardiac Analysis Volume Quant Job Aid

MR Cardiac Analysis Volume Quant Job Aid syngo.via MR Volume Quant provides manual delineation of lesions on Parallel 2D images which can be performed in the Cardiac Reading step. Note: You would want to create this after the Ventricular Function Analysis so that you get a percentage value. 1. From the Patient Browser, load the appropriate data set into the MR Cardiac Analysis Workflow:  If the examination has been correctly mapped, double‐click to load  If manual mapping is required, right‐click the examination and select Assign Workflow > MR Cardiac Analysis 2. The Cardiac Reading step enables you to view and evaluate functional, dynamic, tissue characterization and flow data using common tools. 3. Images are loaded and displayed in 2D mode. In a 2D segment > select Volume Quant from the upper right corner menu Distance Lire MR Cadias Analysis ROIFrethand CURRENT Marker Arrow Angle  STUDY ID FEM 12S Text T Volume Quant TE 1.5 SP FIE Cr Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date: 09/04/2019 | HOOD0516200302722 Job Aid | MR Cardiac Analysis Volume Quant Effective Date: 09/04/2019 | HOOD0516200302722 4. A mini toolbar is displayed Type New Lesion Create 5. Draw a ROI in the image. Note: For each ROI, the individual area and its intensity distribution are listed. The lesion’s volume is displayed. If the result of the left ventricle analysis is available, the volume is also displayed as a percentage of the LV myocardium. 6. If necessary, go to the next slice and draw a further ROI to define the lesion. Lesion 1 Area: 0.58 cm2 Mean/SD: 2374.03 /75.98 TotalVolume: 7.71 cm3 % Myocardium: 4 % 7. To classify the lesion, select the ROI and assign a type in the mini‐toolbar or enter a new clinical category directly into the text field below Type. Type Lesion 8. Select the New icon to abort the definition of the currently active lesion. Note: All corresponding ROIs are deleted. Type New Lesion Create 9. Select the Create icon to create a finding. The finding contains the lesion’s volume and snapshots. o Findings Navigator Name Value Source Lesion1 0.80. MR B .. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 3 Job Aid | MR Cardiac Analysis Volume Quant Effective Date: 09/04/2019 | HOOD0516200302722 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein‐ after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84‐0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 3