MR Cardiac Function - Right Ventricle - Numaris X

BMR MR Cardiac Function – Right Ventricle - Numaris X The MR Cardiac Ventricular Analysis provides assessment of the left and right ventricles. The left ventricle is automatically contoured during the work-flow assignment, while the right ventricle contours can be created with a set of intuitive tools. 1. From the Patient Browser, load the appropriate data set into the MR Cardiac Analysis Workflow  Rght-click on the patient examination and select Assign Workflow > MR Cardiac Analysis  Double Left Click on Patient to open 2. The Cardiac Reading Step enables you to view functional, dynamic, tissue characterization and flow data using the common tools 3. Select the MR Cardiac Function Step MR Cardiac Analysis MR Cardiac Reading MR Cardiac Function Normal Manual Mode  Note: MR Cardiac Analysis performs segmentation of the left ventricle automatically by recognizing the anatomical landmarks (Apical Extent, LV Blood Pool Point, RV In- sertion Point and the Base Plane Points) SIEMENS Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Healthineers Job aid: Effective Date | HOOD# Job Aid MR Cardiac Function – Right Ventricle- Numaris X Effective Date: 01/17/2019 | HOOD05162002981768 4. Perform RV analysis, you can segment the right ventricle using the User Guidance or direct editing using the segmentation tools. If you need to edit the segmentation of the RV analysis, select Guidance RV Analysis Refine Segmentation + Endo Epi Pen Circle Nudge Freehan Edit x Delete Delete All Guidance Propagate ED/ES Join .  Note: The Guidance feature assists you with a recommended workflow for refining seg- mentation and guides you through each of the steps required to perform the segmenta- tion. The Set Landmarks tab and the Refine Contours tab guide you through segmentation. When you select the Refine Contours tab, the corresponding icons are ac- tivated in the Case Navigator. If you do not want to use the Guidance, contours can be created and refined using the contour editing and contour creation tools. 5. Start Segmentation refinement and follow guidance steps: A. Check the ED and ES phase for accurate segmentation. If the Set Landmarks tab is selected > correct the selection in the TVG segment. Drag the ED and ES slider to the appropriate positions. 25 120 0.00 108 0.00 96 0.00 84 72 0.00 60 0.00 48 0.00 36 0.00 24 0.00 12 0.00 10 20 40 50 80 90 % 110 220 331 551 661 771 881 992 11/12 m2 es ED RV EF RV Moss .... g RV ED Volume .... ml RV ES Vclune .... Il Set Landmarks Refine Contours Check ED and ES Step 1 of 2 Check if the position of the ED/ES slider correctly identifies ED and ES. To correct the position drag the ED/ES slider as shown in guidance image. 10 20 30 40 50 175 263 351 439 . ED ES Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 6 Job Aid MR Cardiac Function – Right Ventricle- Numaris X Effective Date: 01/17/2019 | HOOD05162002981768 B. Define the base plane in the long axis working segment by defining two points at the tricuspid valve on ED slice with a left click, then scroll to ES slice and reposition the points at the valve by click and drag. Points should then move along the valve plane as you scroll through phases. Set Landmarks Refine Contours Base Plane Step 2 of 2 Set landmarks on ED and ES on standard "4-chamber" view according to guidance images. ED ES Please note: For optimal accuracy check/correct contours on all This is required if you are interested in parameters that phases. are not determined by the segmentation in ED/ES alone (e.g. peak ejection rate) C. Check the Refine Contours tab gives you an overview of the different tools to define Right Ventricle Analysis. I. Select mid ventricle slice, ensure segments are viewing ED slice and ES slice II. Select pen tool from RV common tools RV Analysis Refine Segmentation Endo Eci Nudge il Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 6 Job Aid MR Cardiac Function – Right Ventricle- Numaris X Effective Date: 01/17/2019 | HOOD05162002981768 III. Draw contour from one insertion point to other insertion point HL Cardiac_Flow, @ Cardiac Dot Engine Anlagenzentrum *6/21/1968, F, 50Y CURRENT MAGNETOM Sola 6/18/2018 Cine_Segmented_SA_01 2:19:14 PM 11 2 IMA 25 ARH SP A33.4 TT 1112.6 SL 8.0/2.0 FoV 339*342 TR 44.2 222*224 TE 1.2 ED Cor-Sag(40)-Tra(-27) TA 08.22+9 45€ .. TRO/NORM/DIS2D/MFSPLIT 192 nE' RR 1159 +/- 46; 8 heartbeats IV. Select propagate > Contour will propagate to phases of all slices RV Analysis Refine Segmentation O. Nudge i ENES V. Select join VI. Return to first slice and edit contours as needed. 6. Create/editing MR Cardiac Function Findings – Throughout MR Cardiac Analysis, all standard measurement tools are available to create findings. The results of the current functional analy- sis are available in the Findings details. The wall thickening results of the LV functional analysis is documented in an AHA-conforming model. LV and RV findings can be created separately us- ing the corresponding buttons in the Findings details. A. Select the Findings details icon in the Findings Navigator > a Findings details dialog box will open Findings Navigator Name Value Source B. In the Findings details dialog box – Choose the heart rate of the patient  The heart rate influences the cardiac output Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 4 of 6 Job Aid MR Cardiac Function – Right Ventricle- Numaris X Effective Date: 01/17/2019 | HOOD05162002981768 Findings details ? X Patient Name: Cardiac_Flow“@Cardiac Dot Engine Export Result Images All Age: 50 Years ED and ES Height: 66.92914 Inches . None Weight: 154.185 Lbs Heart Rate: 52 beats/min Create LV Findings Create RV Findings ( max 56; min: 49; ava:52: med.51 1 C. If contours are to be sent to PACS, choose a selection from export results images.  None is the default Findings details ? X Patient Name: [email protected] Dot Engine Export Result Images @ All Age: 50 Years @ ED and ES Height 66.92914 Inches . None Weight 154.185 Lbs Heart Rate: 52 beats/min Create LV Findings Create RV Findings (max:56; min:49; avg:52, med:51 ) D. Select the check box to use the Long-axis and short-axis or to use short-axis only for a LV and RV functional analysis or to functional analysis Results Long- axis and short- axis @ Short-ads only Export Results LV LV NORM RV RY NORM LV Thickening E. Click Create RV Findings – The findings are listed in the Findings Navigator and are added to the report. Findings details Patient Name: Cardiac_Flow'@ Cardiac Dot Engine Export Result Images A 50 Years ED and ES Height 56.97914 Inches None Weight 154. 185 Lbs Heart Rate: 52 ~ boats/min Create Ly Findings Create RV Findings [max.56; min:49; avg:52. med:51 ) Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 5 of 6 Job Aid MR Cardiac Function – Right Ventricle- Numaris X Effective Date: 01/17/2019 | HOOD05162002981768 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instruc- tions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 6 of 6