MR Composer Workflow
MR Composer Workflow Job Aid syngo.via MR Composing is a general function, which can be included in several workflows. By default, the following workflows contain composing: MR Whole Spine workflow and MR Angio Multi Station workflow. In other workflows, the Composing function can be added via the Workflow Editor. The Composing step for composing: Multiple stations of spine images Multiple stations of angiography images Multiple stations of MIP images Multiple stations of other suitable images 1. From the Patient Browser, load the appropriate data set into the appropriate workflow: If the examination has been correctly mapped, double click to load If the manual mapping is required, right‐click the examination and select Assign Workflow>Desired Workflow In this example, the assign workflow is MR Whole Spine Workflow is used 2. Go to the MR Composer task, then select > New Compose MR Composer New New Compose Combine 3. A Create New Composition dialog box opens: Select the series you want to compose Select the algorithm Enter a name for the composed series and cofirm with OK to start composing The dialog box is closed and the result series is displayed in the corresponding segments Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date: 07/31/2019 | HOOD05162003026176 | MR Composer Workflow Job Aid Effective Date: 07/31/2019 | HOOD05162003026176 Create New Composition ? × Selected Series Available Series t2_tirm_sag.latest H_tse_sag.latest t2_tirm_sag_1.latest H1_tse_sag_1.latest 12_space_stir_cor_cs6_iso.latest 12_tse_sag_1.latest H1_tse_sag.latest 11_tse_sag_1.latest 12_space_stir_cor_cs6_iso latest 12_tirm_sag.latest t2_tirm_sag_1.latest 12_tse_sag.latest Composing Algorithm Spine algorithm Name Of Composed Serie: Composed Stir Sag OK Cancel 4. Edit the Composing Right mouse click the composed series and select > Edit Composing Create New Composing dialog box opens i. Adjust your settings and start composing again ii. Note: The previously composed images are overwritten with the new series 5. Select the Confirm Result Icon MR Composer New New Confirm Compose Combine Result Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 3 | MR Composer Workflow Job Aid Effective Date: 07/31/2019 | HOOD05162003026176 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein‐ after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84‐0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 3
- MR Composer Workflow