MR Spectroscopy 1H CSI JobAid

MR Spectroscopy 1H CSI JobAid

MR Spectroscopy 1H CSI syngo.via syngo.MR Spectroscopy is a post-processing application to analyze and evaluate MR Spectroscopy 1H datasets. It provides evaluation of MR Single Voxel Spectroscopy (SVS) and MR Chemical Shift Imaging (CSI) data with workflow guidance to support the diagnostic process. A novel fit-algorithm reduces the need for manual data processing and offers the user reproducible evaluation results. Info: syngo.MR Spectroscopy doesn’t support the following image types for evaluation  Distortion-corrected images  Images with different frames of reference (e.g., images acquired with different table positions 1. From the Patient Worklist, load the appropriate data set into the MR Spectro Workflow a. Examination correctly mapped: double click to load a. Manual mapping required: right click the examination and Open With > MR Spectro. Open Ctrl+O Open with - Favorites View as Read-Only with - Suggested Batch Open Assign Workflow MR Neurology Group Studies MR Oncology Batch Assign Workflow MR Prostate MR Spectro Cancel Workflow MR Tissue4D Search Patient with DICOM Q/R MR Whole Spine * Add to Demo List › More Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date:02/18/2020 | HOOD/HILS HOOD05162003063282 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 2. MR Spectro Workflow a. MR Spectroscopy Evaluation : assigned MR Spectro has one workflow step SIEMENS Administrator ? 2 0 INAAWON!) MR Spectro ... IChoWCr1) Imins WOr1) MR_Spectro_Head Av_Demyelin_CSISVS Radiologie Ur Tuebingen MR_Spectro_Head Av_Demyelin_CSI+SVs MR Spectro Analysis Radiologie wy Just an 485034 Ret RAARKEP 485034 "12 8/1963, M, 19Y Avanto BYng8 MAR 2004V 4VB11A "12/8/1963. M. 19Y CURRENT HES CURRENT cal se 155, 11/13/2003 3:22. 12 brm tra_datie ffuld $V$ 5 30 01/17_se_30/Spectrum (Sise_30.11/13/2003 3:32 ->Spectro!.Refimage, 1 L esi se 30 # 0002134217 -> Spectrol Specfroml 1 # 0002134217 SVS_Se 30: 11/13/20012:37 STUDY 1 STUDY 1 5.0 av se.30 11/19/2003 11/12/2003 sys_de_30,11/13/2003-2 43 3 00:54 PM 3 37.54 PM ES 80 30 genes 2 Senes 16 Cri 1: 24.64 3.0 Che R E. 44.8 1cm 25 Res Past ww Viewing SP.H40 4 V FOY 249-230 TR 1500 40 11 Tra>Con[-6) NA 126 TA03:18 VOX AP LR FH 1201_21/150 VOK AP LR FH SIZE 20 20 20 Potentially off-label use in USA Integral POS A17 L16 H42 SICE 20 20 20 MR_Spectro_Head Av_Demyelin_Cai+SVS Radiologe Un Tuebingen MR_Spectro_Head Av_Demyelin_CSivsVS Radologe Un Teatrogp 488034 RE PAARKEP 485034 Findings Navigator Avanto "12/8/1963. M. 15Y Avanto Syngo MF 2004V 4VB11A "12/5/1983. M. 19Y Name Value Source CURRENT HE'S CURRENT 12_the_cor.2mm 440, pitz latiet latest "> SpectroI Fenmsge 2 # 0002134217 -a Spectro! Pentmice 3 # 0002136217- STUDY 1 STUDY 1 11/13/2003 11/13/2003 3 08:47 PM 3:09:35 PM Series 4 Tools A L Siren Full Tod How Hoe Lines Reset MRI 4 MAI MRI 5 MA 1 SP A10.3 SPL19.6 MPR THICK EL 3:0 MPR THICK TR 4000 FOV 249 230 EL 3.0 TR 4210 TE 102 FOV 238-220 TE 104 Con Tra(-7]-Sag(-0) Sag>Com(3)>Tra(-3) NA 3 NA2. Edf Snapshot Print Export Undo Heco VOK AP LR FH VOX AP LR FH Layout 10 Finding Stack Stack "tse2d1 13/150 SIZE 20 20 20 SIZE 20 20 20 3:35 PM 3. Performing MR Spectro Analysis a. MR Spectro Navigator is displayed in the control area of Spectro Analysis MR Spectro + b. MR Spectro Analysis Step allows the calculation MR Spectro Analysis and visualization fo spectroscopy results for all csi_se_135,11/13/2003 3:22. Spectro raw data series tha are contained in the wcsi se 135 csi se_30,11/13/2003 3:32 i assigned study. Ww csi se 30 svs_se 30,11/13/2003 3:37 We svs se 30 i. Automatic or Manual selection of a svs se 30.11/13/2003 3:43 svs se 30 post-processing protocol ii. Automatic Calculation and T+ M. AB Visualization of post-processing + rda Export Export, Export Spectro Compare Selected Selected Browser results iii. Each Spectroscopy raw data set, Viewing results are generated based on an assigned post-processing protocol iv. Display individual spectra for CSI measurements Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 11 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 c. Spectro Object: Spectroscopy results i. First line: Measurement series ii. Second line: Post-processing protocol used Icons on Left of Spectro Object Customer Protocol Siemens Protocol Icons Right of Spectro Object Post processing protocol successfully applied to measurement series Post-processing algorithm failed; hover mouse over icon to display reason X for failure and suggested corrective action. 4. MR Spectro Analysis > select an CSI sequence a. Reference images and MR Spectrum Results are automatically displayed MR Spectro ++ MR Spectro Analysis csi se 135,11/13/2003 3:22 csi se 135 csi se 30,11/13/2003 3:32 Ww csi se 30 svs se 30.11/13/2003 3:37 I svs se 30 svs se 30,11/13/2003 3:43 I svs se 30 M+ AB rda Export Export Export Spectro Selected Compare Selected Selected Browser Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 11 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 5. CSI Images: results are automatically displayed a. Reference images b. Metabolite Image c. Spectral Map d. Spectrum (enlarged) 11.38 % AH MR Spectro Head Av_Demyelin_CSH+SVS se Ur Tuebingen 485034 Rer: RAARKSP MR_Spectro_Head_Av_Demyelin_CSI+SVS MNAA) Radiologie Uri Tuebingen MR_Spectro_Head_Av_Demyelin_CSI+SVS. 1(Cho) "12/8/1963, M, 19Y Avanto V4V811A "12/3/1983, M. 19Y Avanto 480034 Ref: PARKSP 485034 Tyngo MR 2004V AVSHA Avanta CURRENT HFS CURRENT HE'S "12/8/1989, M. 19Y "12/8/1983, M. 19Y WOOD MR 2004V AVELLA cal_ge_135_T2 +LFH CURRENT SY1109 MR 2004Y 4Y811A HFS CURRENT Istesbcal ge 135/Spectrum 12 brm tra darlahija 12 trm tra don had -> Spectrot. Rennage 1 #0002134217 -> Spectro1 Spectrum t latort # 0002134217 -> Spectro1 MecscoreImage 1 -> Spectro1 Metacoste magens STUDY 1 STUOY 1 0 4D # 0082134217 # 00021 34217 11/13/2003 11/10/2003 STURE 3:00:54 PM 3:22:37 Ft4:35 1241 31/1974703 3.00 06 PM LALUN.L.ILAL 0.10 0.05 CSI F 0.00 CE SP H47 6 MAI 2 MA 1 -0.05 SP Ha 51 10 BL 10:31 MRI 2 MAI SL 18.52 SP H37 1 SP H37.1 40 35 3.0 25 2.0 Tra Tra MPR THICK SL 3.0 TR 1500 15 10 0.5 MFR THICK MER THICK TR 9000 DV 230-273 TE 109 Tra>Con-6) TE 135 TR 9000 FON:230/237 TR SOCO Chemical saft [ppm] TE 109 Tra>Con(-6] TE 109 TrasCorce) TA 07,12 VOX AF LR FH NA 1 VOX AP LR FH POS A19 L6 H39 VOX AP LR FH Zurzeit_21/150 SIZE 10 10 10 HE 1-4Potentially oft-label use in USA Tradi 21/150 CH_36190 Inegral EIZE 10 10 10 Tradi_21/150 SIZE 10 10 10 Voocel 137 Vogel 137 Maxel 137 Vacel 137 MR Spectro Head Av Demyelin C5H+SVS Rsdoccie Uni Tuebingen MR Spectro Hood Av Dumyelin CSI+SVS 485034 Ret PAARKSP 465034 *12/8/1983. M, 19Y Avatito CURRENT 3YTOO MR 2004V 4V811A +12/8/1983. M. 1BY HPS CURRENT 12 Be cor 3mm_4481_putz Lobest lacest > Spectro1.Hetmage.2 # 0002134217 -> Spectro1 Reflitage STUDY 1 # 0002134217 STUOY 1 A C9 SP A130 SL 10 MF1 4 MAI Tra SP A22.0 Tra MPR THICK 5L 3,0 TR 4CCO FuV.230 273 TR 4719 TE 104 Cor> Tra[6] TE-102 VOX AP LE FH 'T3e2d1_13/150 SIZE 10 10 10 Vowel 137 Vavel 137 6. Result Table: automatically displayed in the upper right corner once a CSI sequence is selected I(NAA)/I(Cr1) (Cho)/I(Cr1) Define Result Table Define Result Table ? X Defined values I(NAA)/I(Cr1) I(Cho)/1(Cr1) Define new value I(NAA)/I(Cr1) Integral Examples >> Add OK Cance Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 4 of 11 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 7. Edit Result Table a. Upper Right Corner Menu select Define Result Table I(NAA)I(Cr1 I(Cho)/I(Cr1) Define Result Table Define Result Table X Defined values b. Define a New Result Value I(NAA)/I(Cr1) I(Cho)/1(Cr1) i. New Value Field: enter expression 1. e.g., I(Cho), I(Cho)/I(Cr) ii. Select Add icon iii. Select OK c. Delete Result Value Define new value I(NAA)/I(Cr1) i. Select Result Value > Select Minus icon << Examples Add ii. Select OK Examples: "Integral of NAA" write: d. Reorder Result Value I(NAA) "Integral of Cho plus integral of NAA" write: i. Select Result Value > Click Up or Down I(Cho) + I(NAA) 'Sum of Integral of Cho and Cr divided by integral of Ci" write: Arrow icon (or) Click a Result Value (I(Cho) + I(Cr))/I(Ci) "Scale Factor of NAA" write: SF(NAA) and drag to a New Position protocol . Note: Availability of items is depending on the underlying ii. Select OK OK Cancel 8. Compare Mode: open one Spectroscopy dataset and compare two voxels (or) select two Spectroscopy datasets and compare two TE’s. a. Compare two voxels in one CSI Spectroscopy dataset i. Select a CSI Spectrum sequence (e.g., csi_se_135) ii. Select Compare icon iii. Top Row: select a Voxel in the Spectral Map for comparison iv. Bottom Row: select a Voxel in the Spectral Map for comparison 1. Note: Spectral Map, Single Spectrum & Metabolite images are displayed v. Two different voxels within the same spectrum are compared 23 973% MR Spectro Q + MR Spectro Analysis 483034 Fiet RAIANSP IINA Ratinge lin Tintrigen MR Spectio_Hesit Av_Demyelin_CSI-SUS Ch Awarto 40:1034 CURRENT SIDO MR 1004V 4VBITA "12/0/1983, M. 19Y Tipo MIR 2004V 4VB11A CURRENT IFS CURRENT CURRENT Istest Spectint Reimage 1 rSi se 30 # 0002194917 5.0002134217 STUDY 1 no_3 30 11/132001 3:37 11/13/2099 100 54 PM 5.32 37 PM 04 343 5: 30:11/1 3/2003 3:43 --- - Viewing IF 8514 42 SP H37 1 Tra SF H37.1. 35 30 Fav 220-273 FOV-200-237 MPR THICK TR 9000 FOY 230-237 TrasCor(E) TE 109 Chenical shit japol TE 109 Tra> Cont-El YOK AP IR TH TA 9 12 VON AP LR TI seit 10 10 10 IChoMiCrtl 10 08 % Findings Navigator Austinje Un Turtingm VR Spectre 480034 Fat PAARKER AV Den Ref: RA4FKBP MR_Spectro Hemd_As_DamysEn_Cal+SYS |IN Rido oge Uni Tuazeigen MR_Sprobe Head Aw_Demyelle_C81+808 |Cho) 483034 455034 Fer FAIPNGP 48:1034 MFarto MIÇO MR 2004Y AVGHA 330/1300 M. 19Y Averto TUDO MIR 2004V 4/3116 CURRENT CURRENT Ango MR 20DE AVEIA CURRENT CURRENT A CO02134217 STUDY Y # 0072134211 11/13/2033 920:54PM Tools Fill Text Hide Hoe Lines Reset EL 10 21 8. 10 92 Graprica Teve por SPHITI HP H37.1 MER THICK SP -371 MFR THICK 35 TR 5000 FOY 280057 TR 9300 TR 9000 FOY 2330-2:37 TE 109 FOV 230 275 TropCot E TE 135 Troscon-0 TE 105 TrasCor-4) NA4 VOK AP LA PH VON AF LR FH AB VOX AP LE FH lage TA 02 12 SIT 30 10.10 182al_24/109 921 10 10 10 SIZE : 10 10 10 Voarl 134 Compare vi. Turn off Compare Mode: when finished comparing 2 voxels Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 5 of 11 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 b. Compare two CSI Spectroscopy datasets with different TE’s i. Depress Ctrl and left mouse > select (2) CSI sequences e.g., csi_se_30 and csi_se_135) 1. Select Compare Icon 2. Top Row: CSI sequence (e.g., csi_se_135) 3. Bottom Row: CSI sequence (e.g., csi_se_30) a. Note: Spectral Map, Single Spectrum and Metabolite images are displayed ii. Turn off Compare Mode when finished comparing CSI TE’s 0.73% MR Spectro MR Specire Head Av_Demgelis Csi+SVS Mit Specim Haad Av Dem MR_Spectro_Head Foi clage UIT Tuebingen MilSpectro_Head Av MR Spectro Analysis Aparte 405034 Re: RAARKOP 485034 Avolto +13/9/1 983. M. 19Y CURRENT CURRENT JOINR 2004V 4VBTIA CURRENT CURRENT Inesors te_175 Spectrum Cho # 0002134217 STUDY 1 # 00021 94213 1 9.73 STUDY 1 11/13/2000 Deries 14 O Viewing F Tra V 11 MPP THICK 30 20 TR 9500 FOV 2207-237 TE 108 Chemical shet [pon] Tra>Con-6) YOX AP CE FH SCE 10 16 10 KNAAINCITY Findings Navigator MR_Spectro_Heail Av_Demgeil_CSI+ BVS Roodlogie Uni Turtingen 625% 485-094 Ret. RAAPSP Mit_Spentre_Head Av_Dem, -85034 MR Spectro Had Av Demyoon_Cal-SVS 0 Rachat Uhs Tiporijen MR_Spectro Heail Av_Demyoin_CSI+SVS |Cho) 51 Snapshot Spect +120/12E0, M. 10Y CURRENT TWIDO MER 2004Y A 9 11A Ty003 MR 2004V dvB11A CURRENT ntigo NR 2004V 4VS114 CURRENT CURRENT -> Spicruz Coachun 1 #0002134237 Sto:tros Metabisimmigr STUDY1 14 11/13/2003 3.00 E 10.19 Real Fort Tools F Hoe Hoe Lites Reset Reset Braptics TineDol TeneDol Tra Tra MOR THICK 90 HST 1 30 25 20 MPR THICK TH 9500 TH 1800 TE 100 TE 105 tra>con-B Layout Snapshot TAG? IT MJX AF LR FH VOLK AF LE PH 312d 1_21/150 WOX AF LA PH HAT Stack VOR AF LA FA 602 10 10 18 SIZE D-40 19 SIZE 10 10 10 SIZE 10 10 19 10:48 PM 9. Metabolite Images: Create metabolite images a. Select a Metabolite Image b. Upper Right corner menu > select Define Metabolite Image Define Metabolite Image Define Metabolite Image ? X MR_Spectro_Head_Av_Demyelin_CSI+SVS 485034 I(NAA) Distance Line "12/8/1983, M, 19Y ROI Circle Value CURRENT 12 tirm tra dark-fluid latest Pixel Lens I(Cho) + I(NAA) -- > Spectro1.Metabolitelmage 1 # 0002134217 Marker -IT Examples >> 11/13/2003 3:00:54 PM Series 24.18 Arrow VOI Freehand OK Delete Cancel 3.22 R Angle A 2.27 Text T CS F SP H47-6 SL 10.31 MRI 2 IMA 1 Tra SP H37.1 MPR THICK SL 3.0 TR 9000 FoV 230*237 TE 109 Tra>Con(-6) NA 1 "tir2d1_21/150 VOX AP LR FH SIZE 10 10 10 Voxel 139 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 6 of 11 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 c. Define Metabolite Image dialog box displayed i. Value: enter and define definition of a metabolite, examples of various parameters that can be entered 1. Integral values: I(Cho) 2. Integral of Cho plus integral of NAA: I(Cho) + I(NAA) 3. Sum of Integral of Cho and Cr divided by integral of Ci: (I(Cho) + I(Cr)/I(Ci) 4. Ratios of integral values: I(Cho)/I(Cr) 5. Scale-factors: SF(Cho) ii. Examples button: select to view Define Metabolite Image definition examples Value 1. Note: availability of items depends on the I(Cho) + I(NAA) << Examples underlying protocol Examples: 2. Select OK: newly defined "Integral of NAA" write: metabolite image displayed in segment Sum of Integral of Cho and Cr divided by integral of Ci“ write: (I(Cho) + I(Cr))/I(Ci) Scale Factor of NAA" write: SF(NAA) Note: Availability of items is depending on the underlying protocol. OK Delete Cancel d. Adjust Range and Transparency - Lower Right corner menu i. Select Adjust Range & Transparency MR_Spectro_Head_Av_Demyelin_CSI+SVCho) + I(NAA) Radiologie Uni Tuebingen Ref.: RA4RKSP ii. Intensity Range 12/8/1983, M. 19Y Avanto syngo MR 2004V 4VB11A CURRENT HFS 1. Define Upper and Lower limits t2_tirm tra dark-fluid latest -- > Spectro 1.Metabolitelmage.1 2. Select Absolute or Percentage # 0002484217 STUDY 11/13/2003 iii. Automatic: when activated, automatic 3:00:54 PM Series 2 7.06 display of intensity range so the range between the maximum and minimum 5.69 Check Spectral Quality values in the metabolite images is Metabolite Image Color .32 used Interpolation On/Off CSI Adjust Range & iv. Transparency SP H47-6 Transparency SL 10.95 Tra 1. Slider: use to modify the AutoWindowing - MPR THICK TR 9000 transparency of metabolite TE 109 MR Color LUT 2. NA 1 image *tir2d1 21/150 MR Presets -O- 2. Enter Percentage Voxel 139 Reset Windowing v. Reset button: select to reset range and transparency Intensity Range 2,95 8.42 Absolute Automatic Transparency Reset 50 % Information: intensity range is set for the complete CSI slab in case of 3D Information: The Intensity range in relative percentages represent the minimum occurring value in the metabolite image as 0% and the maximum occurring value as 100% Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 7 of 11 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 10. Peak Information Map: Show/Hide Peak Information Map a. Upper Left corner menu > select Show/Hide Peak Information Map and toggle on/off i. Peak information map displayed/or removed on Metabolite image Show Peak Information MapAH Hide Peak Information Map Show Quality Markals SV Cho) + I(NAA) Show Quality MarkalsSV Cho) + I(NAA) Show Selected Voxel Only Show Selected Voxel Only Show Peak Information Map Hide Peak Information Map AH AH MR_Spectro_Head Av_Demyelin_CSI+SYSho) + I(NAA) Radiologie Uni Tuebingen MR_Spectro_Head Av_Demyelin_CSI+SVS Radiologie Uni Tuebingen 485094 Ref.: RAARKSP 485034 "(Cho) Ref: RAARKSP "12/8/1983. M. 19Y Avanto Avanto syngo MR 2004V 4VB11A "12/8/1883. M. 19Y Syngo MR 2004V 4VB11A HFS CURRENT HFS t2 tirm tra_dark-fluid 12 tirm tra dark-fluid Latest latest -> Spectro 1.Metabolitelmage -> Spectro 1 Metaboltelmage 2 # 0002434217 # 0092534217 5.517.786.765 65 5 76 6 876 76531 STUDY 11/15/2003 PM 3:00 50 PM Series 2 4.27 8.897.116.11 6806 095887.18657 R 5,69 7.186 096.115.19 0.71 8.59 68 997 3.02 7.20 8:426.505-016 397/107 57970 1cm 6:2 7:536 585 906 296496 94861 1.77 3 124 253 16 2 953 223 663 77361 F CSI CSI IF SP H47-6 SP H476 SL 10 95 MRI 2 IMA 1 SL 10:52 MRI 2 1MA 1 Tra SP H37:1 Tra SP H37:1 MPR THICK SL 30 MPR THICK SL 3 0 TR 900D FoV 230-237 TR 9000 FoV 230-237 TE 109 Tra>Cor(-6) TE 109 Tra>Con(-6) NA 1 NA 1 YOX AP LR FH VOX AP LR FH "Zir2d1_21/160 SIZE 10 10 10 "wir201_21/150 SIZE 10 10:10 Voxel 237 Voxel 139 11. Update Spectrum Real Time a. MR Spectro Analysis > Select a CSI sequence b. Right-click on Reference Image or Metabolite Image segment > Select Context Menu > Real Time Spectrum update c. Move mouse over voxels on the metabolite image to see real time updates of enlarged spectrum Mark Voxel as Low Quality Real Time Spectrum Update Paste Measurement Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 8 of 11 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 12. Spectral Map a. Show/Hide Spectral Map b. Upper Left corner menu > select Show/Hide Spectral Map to toggle on/off c. Spectral map displayed/or removed on image Show Spectral Map AH Hide Spectral Map Show Quality Markers SI+SVS Demyelin_CSI+S Show Quality Markers Show Spectral Map Hide Spectral Map CURRENT HFS MR_Spectro_Head_Av_Demyelin_CSI+SVS Radiologie Unil Tuebingen t2 trm tra dark-nuld 485034 Ref. RAARKSP latest "12/8/1983, M; 19Y Avanto -- > Spectro1 Refimage. 1 syngo MR 2004V 4VB11A # 0002134217 CURRENT HFS STUDY 1 t2 tirm tra dark-fluid latest 11/13/2003 -- > Spectro 1 Refimage 1 3:00:54 PM # 0002134217 Series 2 STUDY 1 11/13/2003 3.00:54 PM Series 2 R ILAL 5cm 5cm CSI IF CS F SP H47.6 SP H47.6 SL. 10 MRI 2 IMA 1 St. 10 MRI 2 IMA 1 SP H37.1 Tra SP H37.1 MPR THICK SL 3.0 MPR THICK SL 3:0 TR 9000 FoV 230*273 TR 9000 FoV 230 273 TE 109 Tra>Con(-6) TE 109 Tra>Cor(-6) NAT NA 1 VOX AP LR FH VOX AP LR FH tir201_21/150 SIZE 10 10 10 "tir2d1_21/150 SIZE 10 10 10 Voxel 168 Voxel 237 13. Curve Display a. Select Spectrum i. Lower Right corner menu > select Curve Display Options ii. Check Fit radial button to add Red Curve Fit iii. Un-Check Fit radial button to remove Red Curve Fit iv. Peak Information: select up to 3 to display on spectrum 00 check Spectral Quality auto Display Options ? × 4.0 3.5 Show Individual Fit Curves TR 1500 3.0 Curves Peak Information Metabolites TE 135 Chemical shift [ppm] Manual Phasing 1 NA 4 Signal Name NAA TA 07:12 HE 1-4Potentially off-label use in USA Curve Display Options Fit ¥ Integral V Cr1 csi se/90 . Baseline Width Cho Voxel 1Adjust Range & Scale Subtract Baseline Scale Factor Cr2 Position OK Reset Cancel Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 9 of 11 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 14. Check Spectral Quality a. Quality Check Condition i. Checked: quality check condition for each voxel not manually marked as low quality is re-evaluated. Based on the result, the display of the spectral map and metabolite image are updated ii. Un-checked: voxels that were marked as low quality by the quality check are now marked as high quality. The status of any voxels that were manually marked as low quality is not changed. b. Marking a Voxel as Low Quality: that have low Quality Spectra and discard their values i. Checks all “hot spots” in metabolite images and ensure they have corresponding high-quality spectra o.o VIN Check Spectral Quality Check Spectral Quality ? X auto Quality Check Condition TR 1500 4.0 3.5 3.0 Show Individual Fit Curves Quality Check Condition TE 135 Chemical shift [ppm] Manual Phasing &Residual(Lipids_vs_Noise)<3008&1(Cr2)<2*(I(NAA)+I(Cr1)+I(Cho))&&SNR()>3 NA 4 TA 07:12 I: IntegrCurve Display Options << Examples HE 1-4Potentially off-label use in USA csi se/90 Examples Voxel 1Adjust Range & Scale IA If the Signal to noise ratio must be greater than 5 then write: SNR() > 5 If the Signal to noise ratio must be greater than 5 and width of Cr2 must be smaller than 15 then write: SNR() > 5 && W(Cr2) < 15 If the Standard Deviation of integral of Cho must be smaller than 20% then write: StdDev(I(Cho)) < 20 Mark Saturated Voxels as Low Quality OK Apply Reset Cancel Information: Spectral Quality Check is performed by the system.  Voxels of Low Spectral Quality are marked and results are not used or displayed on the Spectral Map or Metabolie Image.  Quality Check Condition determines whether or not a voxel is high quality.  Voxels that don’t pass Quality Check Condition marked as low quality. 15. Findings a. Create or Add findings for spectra results Findings Navigator Name Value Source S1 Snapshot Spect ... 16. Save Results Save and Send: Results are stored on the system and sent to your archive II Save and Pause: Results are stored on the system Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 10 of 11 Job Aid | MR Spectroscopy 1H CSI syngo.via Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063282 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 11 of 11