MR View&GO - Corner Menus

This job aid will review the corner menus of the MR View&GO.

MR View&GO Corner & Context Menus Job Aid MR View&GO – Corner Menus and Context Menu for syngo Numaris X MR Systems. Corner Menus • MR View&GO - Corner Menus are available in the corner of each segment • Select tools without exiting the segment • Tools available depend on the images loaded in the segment and the active workflow. • Note: Some tools are also available in Favorite Tools • Working with Corner Menus – Accessing Tools: • Left-click Watermark in Corner of Segment to open the menu • Tools displayed depend on image/series displayed and current active workflow steps • Left-click Tool to Activate (or) Hover Mouse Over Menu Item • Opens Available Tool Options (if available) • Adjust Tool Settings - Change Tool Properties • Point to Tool > Select Setting Icon • Some tools allow adjustments to tool-specific settings and to set displayed values • Note: settings are applied to all future interactions with these tools • Deactivate Tool • Press Esc key - Deactivates/Closes Current Tool Selected  Upper Left Corner Menu – Image Preparation Tools  Lower Left Corner Menu – Visualization Functions and Display Types  Upper Right Corner Menu – Measurement and Marking Tools  Lower Right Corner Menu – Window Settings and Modality-specific Presets HRA MR_Oncology SPITALUL CLINIC SANADOR Romania_MAC Ref.: Congress *1/1/1964, F, 51Y Skyra CURRENT MR E11 11/13/2015 HFS +LPH t1_tirm_sag_dark-fluid_p latest # VE11 STUDY ID 2aaaa0918 20 IMA 23 AL TI 900.0 TR 2000.0 TE 9.0 TP F13 TA 01:02*3 SP L1.0 BW 260.0 FoV 240*240 p3 M/NORM/DIS2D 256*320 Sag>Tra(-3)>Cor(-1) A1/IR Zoom 1.53 HC1-7;NC1,2 W 860 *tir2d1_4/ 150 463 SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: xx/xx/2021 | HOOD0 Healthineers Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 Upper Left Corner Menu Zoom/Pan • Zoom/Pan – action (Zoom/Pan) depends on position of mouse pointer in image 1. Zoom 1 2. Pan r- • Image Segment > choose Zoom/Pan from Upper Left 2 Corner Menu • Mouse pointer changes shape according to its current position • Zoom > Drag mouse pointer in outer area of image • Drag Mouse Up – Zooms Image In • Drag Mouse Down – Zooms Image Out • Windowing – Modify Image Brightness and Contrast (e.g., Change Width/Center Values) Windowing • Window Images – Press and drag middle mouse button (Scroll Wheel) (or) • Choose Windowing from Upper Left Corner Menu • Adjust Window Center > move mouse Vertically • C (Center) – defines Brightness • Adjust Window Width > move mouse Horizontally • W (Width) – defines Contrast • Rotate – Optimize image presentation by rotating displayed images (or) displayed volume to a new Rotate orientation • Select Segment > choose Rotate from Upper Left Corner Menu > mouse pointer changes shape • Rotate Image or Volume > drag mouse next to image border and rotate in a new direction (e.g., clockwise or counterclockwise) • Rotate MIP & VRT images > Right-mouse button • Rotate MPR images > Right-mouse button + Alt key • Orientation Cube – indicates anatomical image orientation AL • Rotate 90 Icon – Rotate Images 90° Clockwise • Flip Horizontal/Vertical – Flip images Horizontal or Vertical Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 2 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Scroll – Use mouse or keyboard to scroll through images Scroll • Scroll through Images • Select Right-mouse (or) select Scroll Wheel • Select Left-mouse (or) select Scroll from Upper Left Corner Menu • Drag Mouse to Scroll • Deactivate Scroll • Select Left-mouse button > Choose Scroll a second time (or) Press Esc Key Keys Effect in Stack Mode Effect in Stripe Mode Arrow Up/Down Scrolls to the next/previous slice in stack Moves one segment up/down Page Up/Down Moves a predefined number of images forward /backward Moves one segment left/right Arrow Left/Right Navigates in time points or data sets Moves one segment left/right Home Goes to first image in a stack Goes to first image of the stripe End Goes to last image in stack Goes to last images in stripe U Activates & deactivates scrolling with skipping No effect Shift + l Activates & deactivates performance mode for scrolling without skipping No effect • Movie – Scroll through an Image Series, 3D or 4D Il Movie Volume Data Set • Start/Stop Movie – select Movie > Upper Left Corner Menu (or) Press Spacebar • Movie Control Panel – displayed briefly • Movie Icon Hidden – select Movie Icon bottom of segment to reopen 1. Control Icons 2. Frame Rate Slider – Movie speed 1 60 F/s 2 Icons Features 11 Start/Stop movie Movie Direction Go to Previous or Next image Go to Beginning or End Repeat Movie Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 3 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • 3D Reference Point – Navigates to same coordinates of a patient in different series and/or series view. 3D Reference Point • Crosshair Displayed – with same point in all segments that are spatially aligned to each other • Note: 3D reference point is positioned on a volume and can also be displayed in a stack of 2D images (e.g., crosshair is displayed on the best matching slice in stack) • Select 3D Reference Point > Upper Left Corner Menu (or) Press R Key • Click Required Position (or) Drag 3D Reference Point to Required Position • Ranges – Reformat volumetric data as a series of images (i.e. create other anatomical planes or Ranges projections for better visualization. • Note: Arrow Icon has different options Parallel Ranges – creates a series of images Parallel Ranges • vertically to the displayed reference image plane. Radial Sliced Ranges • Radial Sliced Ranges – creates a series of images * that contain cut planes with a defined angle. • Cut Planes are arranges around a pivot Radial Ranges • Radial Ranges – create series of images with different view directions Curved Ranges • Views from reconstruction are arranged around a pivot point • Curved Ranges – creates curved images perpendicular to the displayed reference image plane • Save as Series – After a modification is made to a Series > Save images as a New Result Series. Save as Series • Option for saving new series is only available for planar image display types (2D or 3D Slices) • Steps for Saving • Images are loaded into image area & have been modified • Upper Left Corner Menu > choose Save as Series • Save as Series dialog box opens • Enter Name for New Series • Enter Image Comment (e.g., only if require) • New Series Saved in Results Series Panel > Results Section Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 4 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Fit to Segment – Resizes images in selected segment to original size and location (e.g., removes Zoom/Pan) Fit to Segment • Select Fit to Segment > Upper Left Corner Menu • Note: Arrow Icon has different options • Fit to Acquisition Size – displays selected iamges in original Fit to Acquisition Size (acquired) resolution • Select Fit to Acquisition Size > Upper Left Corner Menu • Flip Images – Optimize image presentation by flipping R A Flip Horizontal displayed images Horizontally or Vertically R Flip Vertical • Flip Horizontal – Flip images Left or Right • Flip Vertical – Flip images Up or Down • Rotate 90 – Rotates images 90° Rotate 90 • Region Growing – Tissue segmentation applies an algorithm Save as Series that detects anatomical structure with nearly the same HU value and creates a separate segmentation object from these Fit to Segment structures. Region GrowingRM/DIS2D • Interactively segments structures (e.g., vessels, bones, AL/SAT1 or organs). Anatomy Visualizer X • Typically used to identify and segment tissues (e.g., aorta, visceral arteries, iliac arteries, kidneys, or liver). Segmentation Objects • Region Growing Segmentation Workflow • Select a 3D Image Segment (VRT, MIP, or MPR) Object 1 Volume • Choose Region Growing from Upper Left Corner Menu OX • Anatomy Visualizer Segmentation Tools • Select Tissue Type from Drop-down list • Depress Left-Mouse On Selected Structure Region VRT Punch FreeHand FineTune Threshold Growing MPR • Position Mouse Pointer on Structure > Depress Left Mouse (mouse pointer changes Region Growing Controls shape) Mode Single click mode Region Grows until Left-Mouse Button Add Tissue Type • Released Remove General Isolate trength • Note: switch between image segments and Apply continue segmentating structures. Undo / Redo • Reverse Region Growing Action – restore/remove last actions • Select Seed Undo/Redo Icon Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 5 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 Lower Left Corner Menu Cinematic VRT – volume rendering technique that provides a HD Cinematic VRT • photorealistic visualization of the human body • Select Cinematic VRT > Bottom Left Corner Menu • VRT (Volume Rendering Technique) – renders and displays different tissue types from CT and MR images in a semi- VRT transparent 3D View. VRT • Note: Select Arrow Icon to see options VRT Thin • VRT – entire volume used to generate 1 rendered image • Choose VRT > Bottom Left Corner Menu • VRT Thin – only a slab of volume is used to calculate rendering • Choose VRT Thin > Bottom Left Corner Menu • Define Slab Thickness • MIP –MIP image reconstruction, entire volume is checked, MIP results in one projection image. • Image Segment > choose MIP from Bottom Left Corner Menu • Note: Select Arrow Icon to see options • MIP Thin – slab volume only used to calculate projection Define Slab Thickness Image Segment > choose MIP MIP Thin • Thin from Bottom Left Corner Menu • MinIP Thin – Creates a minimum intensity projection from MinIP Thin images of a 3D series. • Select MinIP Thin > Bottom Left Corner Menu • Volume Evaluated Voxel by Voxel – in selected orientation. MinIP Thin Properties ? X • Voxels with Lowest Intensity – recorded in a 2D image, result is a parallel projection of a volume. Slab Thickness p.8 mm • MinIP Thin Properties Slab Spacing • Select MinIP Thin > Bottom Left Corner Menu > . Minimum click Properties Icon 100 % of slab thickness • MinIP Thin Properties window 0 0.8 mm • Slab Thickness – change in mm Note: This value must not be larger than the slab thickness. • Slab Spacing – specify space between slabs • Select OK OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 6 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • MPR – combines loaded images in a volume used for MPR calculating cuts in any orientation • Image Segment > choose MPR from Bottom Left Corner Menu • Reconstructs slices that are one pixel thick • Note: Select Arrow Icon to see options • MPR Thick – reconstructs using an individually defined slice MPR Thick thickness (usually thicker than original image) • Image Segment > choose MPR Thick from Bottom Left Corner Menu • Mean Gray Value of a slice used for calculation of displayed gray values • MPR Thick Properties • Select MPR Thick > Bottom Left Corner Menu > click Properties Icon • 2D – displays 2D images • MPR Thick Properties Window – Adjust Settings • Slice Thickness – change in mm • Slice Spacing – specify space between slabs • Minimum – applies smallest space between slices • % of slice thickness – defines space between slice as a portion of slice thickness • mm – defines spacing in mm • Select OK MPR Thick Properties ? X Slice Thickness p.8 mm Slice Spacing Minimum 100 % of slice thickness 0.8 mm Note: This value must not be larger than the slice thickness. OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 7 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 Upper Right Corner Menu • Edit Comment – change image comments in original 2D Edit Comment images • Add To (or) Edit Image Comments in displayed images • Edit Image Comment dialog box • Can Only edit First Two lines of Image Comment • Edit Comment Workflow Edit Image Comment ? X • Select Image Segment • Select Edit Comment > Upper Right Corner Menu V Replace image comments of all images of the same • Edit Image Comment dialog box opens stack. • Replace image comments to all images of the same stack > Check Image Comment 1 Box check box (e.g., Displays comments on each image within a Image Comment 2 series ) • Enter Image Comment 1 • Enter Image Comment 2 (optional) OK Apply Cancel • Select OK • Distance – Measures length in an image SPI Distance Line • Draw Distance Line on One Slice • Select Distance Line > Upper Right Corner Distance Line Menu • Click Start Point > Drag Mouse to End Distance Polyline Point • Distance Polyline – used to measure length of a vessel • Select Distance Polyline > Upper Right Corner Menu • Click Points to Connect Line Segment to Distance Polyline > Double Left-Mouse to Complete Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 8 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • ROI Circle – evaluates statistical values for a circular of elliptical (e.g. measure diameter of a vessel) ROI Circle O • Select ROI Circle > Upper Right Corner Menu Image Segment > Depress Shift + Left ROI Circle O • Mouse Button > Draw Circle (or) Ellipse ROI Freehand ROI Auto Contour • ROI Freehand – mark a specific irregular region • Select ROI Freehand > Upper Right Corner Menu • Draw a ROI Freehand > Depress Left Mouse > Draw Shape • Release Mouse to finish editing • ROI Auto Contour – define contours automatically • Select ROI Auto Contour > Upper Right Corner Menu • Depress Left Mouse > Move Mouse over structure • System suggests contours with a dotted line based on mouse movements • Mark a Specific Structure • Depress Left Mouse > Repeatly Drag and Left-click until entire structure is marked • Selected contour indicated with dotted line • Polygonal ROI – mark a specific irregular region • Select ROI Polygonal > Upper Right Corner Menu • Draw a Polygon > Click Required Points > Double Left Mouse > Closes Polygon • ROI Properties Select ROI > Upper Right Corner Menu > Settings ROI Properties ? X • • ROI Properties Dialog Box Opens • Check Boxes to display required evaluation results Display the following evaluations: • Min/Max – Minimum/Maximum ROI Grayscale Values Min/Max • Mean/SD– Mean Value and Standard Deviation V Mean/SD Grayscale Values in ROI V Area (cm2) Sum • Area (cm2) – ROI Area in cm² • Sum – Sum of All Pixel Values within ROI Number of Pixels • Number of Pixels – Total Number of Pixels Enhancements: within ROI Automatic Contour in Polygonal ROI OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 9 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Pixel Lens – Determines pixel value at a current position of a pixel (or) a voxel Pixel Lens • Select Pixel Lens > Upper Right Corner Menu • Mouse Pointer changes shape • Move mouse pointer across image and left-click a position • Grayscale Values shown beside pixel lens marker 104 R 64 P 32 F 10 • Pixel Lens > Pixel Coordinates Displayed • Viewing Step (or) 3D Step of MR View&GO is Open • MR Images with image plane loaded and 2D View selected • Note: only displayed when Viewing Step (or) 3D Step of MR View&GO is open • Pixel Lens – Calculation of Grayscale values • Note: Depends on pixel lens settings, grayscale value is calculated as follows • 2D images – average of a plane • (1x1), (3x3), (5x5) pixels • Planar Display Types (MPR, MPR/MPR, MPR Thick, MIP Thin, MinIP Thin) • (1x1 x slice thickness) voxels • (3x3 x slice thickness) voxels • (5x5 x slice thickness) voxels • Volume Display Types (VRT, MIP) • (1x1x1) voxels • (3x3x3) voxels • (5x5 x5) voxels • Setting Pixel Lens Properties – Specify Pixel/Voxel Size of Pixel Lens • Select Pixel Lens > Upper Right Corner Menu > Properties Pixel Lens Properties ? x icon • Size of Pixel Lens – Specify Pixel (Voxel) Size of Pixel Lens • Continuous Pixel Lens 1x1(x1) pixel (voxel) • Checkbox – to keep pixel lens 3x3(x3) pixel (voxel) tool activated • Select OK 5x5(x5) pixel (voxel) Continuous Pixel Lens OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 10 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Arrow – Mark/Highlight specific areas in an image, draw annotation arrows Arrow • Select Arrow > Upper Right Corner Menu • Mouse pointer changes shape • Click Start Point > Drag Mouse to End Point (or) • Click Start Point only to Draw a Default Arrow • Text field Displayed next to Arrow • Enter Annotation Text • Enter a line break > Press Ctrl + Return • Only standard characters can be entered • Complete Annotation > Press Return key • Edit Annotation • Select Arrow > Edit Annotation Text from Context Menu (or) Double-click Text • Drag Corner of text field to increase or decrease size of annotation text • Marker – Mark specific areas in an image and label Marker -IT • Select Marker > Upper Right Corner Menu • Mouse pointer changes shape • Set Marker > Click a Position • Position marked with Crosshair • Text field displayed next to crosshair • Enter Annotation Text • Enter a line break > press Ctrl + Return • Only standard characters can be entered • Complete Annotation > Press Return key • Angle – Measure angles between two distance lines Angle • Select Angle > Upper Right Corner Menu • Mouse pointer changes shape • Draw lines to Create Angle • Begin at Vertex of Angle • Tips of lines indicated by graphic identification number and an arrow • Edit Angle • Press Alt key > Drag Endpoint Handles of Either Line to New Position • Move Single Line > Drag Middle of Line to New Position • Move Whole Object > Drag Line between Middle and Endpoint to New Position Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 11 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Text – Label specific areas in an image, insert image text Text T • Select Text > Upper Right Corner Menu • Mouse pointer changes shape • Click position in image segment • Text Field displayed > Enter Annotation Text • Enter a line break > press Ctrl + Return • Only standard characters can be entered • Complete Annotation > Press Return key • Edit Annotation • Select Text Field > Edit Annotation Text from Context Menu (or) Double-click Text • Drag Corner of text field to increase or decrease size of annotation text • Drag annotation text to a new position VOI Sphere • VOI (Volume of Interest) – evaluates stastical values of Spherical, Ellipsoid, a nd Freehand volumes (or) Volumes defined by drawing Freehand Volume Contours. VOI Sphere • VOI Sphere VOI Freehand • Select VOI Sphere > Upper Right Corner Menu • Image Segment > Depress Left Mouse and Draw VOI Sphere • Results Displayed next to VOI Sphere • VOI Elliptical • Select VOI Ellipitcal > Upper Right Corner Menu • Image Segment > Depress Left Mouse and Draw Ellipitical VOI • Results Displayed next to Ellipitical VOI • Freehand VOI • Rotate and Position Image Plane • Select Freehand VOI > Upper Right Corner Menu • VOI Mini Toolbar Displayed > Mouse-pointer changes shape • Auto – performs interpolation automatically when a 3D object is created • Contour – includes the volume between the contours before a 3D object is created • Draw First Contour > Double Left Mouse > Completes Contour • Scroll to another Image Plane > Keep Drawing Contours until All are created. • Select Create VOI – calculates result auto Auto Contour Create VOI Undo Redo Start New Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 12 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 Spine/Rib Label • Spine/Rib Label – depends on selected data set *** • Spine Labeling Only (or) Spine and Rib Labeling available • Note: Depending on workflow, automatic spine labeling may have already run (or) spine label algorithm will start running • Select Spine/Rib Label > Upper Right Corner Menu • Mini Toolbar Displayed • Mini Toolbar 1) Confirms Spine and Rib labels 2) Enables quick insertion of multiple spine labels 3) Resets all label values and locations to initial values 15 7 1 2 3 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 13 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 Lower Right Corner Menu Position Display Series • Position Display Series – Shows display of lines where images were acquired Position Display • Create a Position Display Series (Multiple Slices Displayed) Position Display Series • Select Image Segment • Select Position Display Series Icon • New Series Name “PosDisp” • Series Number shown in Series Navigator with square brackets and Position series name Displa .. • Position Display Selection Position Display Series • Create Position Display Selection (Single Slice Displayed) – Displays a slice on a specific image Position Display selected • Select Image Segment – Coronal, Sagittal, and Position Display Series Transverse Series loaded • Depress Ctrl + Left Mouse > 1st select Coronal Image Segment > select Transverse Image Segment > release Ctrl + Left Mouse • Select Position Display Selection Icon • New Series Name “PosDisp” – Series displays Transverse slice on Position selected Coronal image Display • Create Position Display Selection (Multiple Slice Displayed) – Displays all slices in a series on a specific image selected • Select Image Segment – Coronal, Sagittal, and Transverse Series loaded • Depress Ctrl + Left Mouse > 1st select Coronal Image Segment > select Transverse Image Segment > release Ctrl + Left Mouse • Select Position Display Series Icon • New Series Name “PosDisp” – Series displays all Transverse slices on Position selected Coronal image Displa ... Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 14 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Correction Tools – Function for correcting motion and distortion artifacts Correction Tools • Motion Correction (Elastic) • Correct soft tissue motion of imaging volume • Correction of one or more volumes relative to an initially supplied reference volume • Applications – MR Breast or MR Angio Exams with multiple measurements • Motion Correction (Elastic) Workflow • Select Two Series (minimum) • 1st Series – shows soft tissue motion • 2nd Series – serves as a reference volume • Select Correction Tools > Motion Correction (or) Favorite Tools > Motion Correction • Settings > select a Setting from dropdown • Input Volume > select a Volume • Reference Volume – default Reference Volume Name entered • Result Series Name –default Result Series Name entered • Select OK – Starts Motion Correction and Saves Results • Motion-corrected series is displayed in Series Navigator & Result Segments of Layout. Motion Correction ? X Motion Correction (Elastic) 1) Settings – name of setting 2) Config Icon – settings 1 Settings MR Motion Correction Sett ... Config. 2 3) Input Volumes Input Volumes t1_vibe_dixon_tra_caipi4_bh_opp.latest 4) Remove Icon – deletes t1_vibe_dixon_tra_caipi4_bh_W.latest t1 vibe dixon_tra_caipi4_bh_in.latest selected volumes 3 5) Reference Volume – name of reference volume 6) Result Series Name – name of result series Remove 4 Reference Volume t1_vibe_dixon_tra_caipi4_bh_F.latest 5 Result Series Name Results MoCoHiQ_11_vibe_dixon_tra_caipi4_bh_opp 6 OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 15 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Distortion Correction • Geometric Distortions may occur at edge of images when using a large Field-of-View (FoV) (or) Off-center Slices • Image errors can be eliminated using Distortion Correction • Modes of Distortion Correction • 2D Distortion Correction – Image distortions corrected within an image plane Motion Correction (Elastic) • 3D Distortion Correction – Image distortions of current slice are corrected in all 3 spatial 2D Distortion Correction directions with regard to neighboring slices Reverse 2D Distortion • Reverse Distortion Correction – Removes Correction distortion correction 3D Distortion Correction • Image Filter – post-process blurred images or ImageFilter Smooth images with strong noise • Filters available ImageFilter Medium • ImageFilter Smooth – soft-focus effect • ImageFilter Medium ImageFilter Sharp • ImageFilter Sharp – edge or contrast enhancement • Image Filter Workflow • Select Image Segment • Select an Image Filter • ImageFilter Smooth • ImageFilter Medium • ImageFilter Sharp Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 16 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Analysis Tools – arithmetic and statistical functions for evaluating dynamic processes and images Subtraction • Depending on function – evaluate single images, Addition + more than one image, one series, or more than one series Multiplication Result images are stored in database X • • Analysis Tools Division • Subtraction • Addition *ImADC & b-value • Multiplication Division Arithmetic Mean ThT • • ADC & b-value • Arithmetic Mean • Analysis Tools Prerequisites • Images must have the following characteristics • Originate from Same Examination • Same Field-of-View • Corresponding Matrix Size • Same Slice Orientation • Same Slice Position • Same Intensity Correction (all correct or all not corrected) • Same Type of Distortion Correction (none, 2D, 3D) • Note: system message is displayed when selected images are being loaded if they do not meet criteria Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 17 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Subtraction – Perform on images, series, or 4D data sets to subtract different time phases. • Subtraction Workflow • Depress Ctrl Key > select Segments for Subtraction (or) Segment with 4D data set • Lower Right Corner Menu > select Analysis Tools > Subtraction (or) Favorite Tools area > Subtraction Icon • Create Subtraction Datagroup dialog box opens • Oldest Series Displayed as Subtrahend • Newer Series Displayed as Minuend • Note: Drag Subtrahend to Minuend or vice versa to adapt the Minuend/Subtrahend • Result Series > Enter Name • Select OK – Starts Subtraction • Subtraction Series – displayed in Series Panel and Result Segments of Layout Create Subtraction Datagroup ? X Create Subtraction Datagroup 1 1) Settings – name Current Active Settings 2 MR ViewAndGo Subtracti ... Config. Setting Minuend t1_vibe_dixon_tra_caipi4_bh_F.latest t1_vibe dixon_tra_caipi4_bh_W.latest 2) Config Icon – opens Subtraction t1_vibe dixon_tra_caipi4_bh_in.latest 3 Settings dialog window 3) Minuend – Phases or Series (Newest Series is Displayed) 4 4) Swap Icon – moves select series to swap Remove 5 Subtrahend or Minuend Subtrahend t1_vibe_dixon_tra_caipi4_bh_opp.latest 5) Remove Icon – deletes selected 6 Minuend or Subtrahend 6) Subtrahend – Phases or Series (Oldest Series is Displayed) 7 Use Constant 0 7) Use Constant Value Remove 8) Result Series Name – default name is freely editable Result Series Name Results Sub_11_vibe_dixon_tra_caipi4_bh_F 8 OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 18 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Addition – adds grayscale values of images or to add a constant • Addition Options • Add constant value to a set of images or to a set of series • Add all images in a Series • Add images across Series • Addition Workflow • Depress Ctrl Key > select Segments for Addition • Lower Right Corner Menu > select Analysis Tools > Addition (or) Favorite Tools area > Addition Icon • Create Addition dialog box opens • Summands – Select Phases or Series • Use Constant – set Value (e.g., only if needed) • Result Series > Enter Name • Select OK – Starts Addition • Addition Series – displayed in Series Panel and Result Segments of Layout Create Addition ? X Create Addition 1 Settings MR Addition Settings 2 Config. 1) Settings – name Current Active Setting 3 Summands diff bo-1000-3000 TRACEW.latest.B-Value 01 diff_b0-1000-3000 TRACEW.latest.B-Value 02 2) Config Icon – opens Addition diff b0-1000-3000 TRACEW.latest.B-Value 03 Settings dialog window 3) Summands – Phases or Series 4) Use Constant – set Value 5) Remove – removes Summands 4 Use Constant Remove 5 6) Result Series Name – default name is freely editable 6 Result Series Name Results ADD_diff_b0-1000-3000_TRACEW OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 19 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Multiplication – rescales the grayscale value of images. • Multiply a set of images or series by a constant value • Multiplication Workflow • Depress Ctrl Key > select Segments for Multiplication • Lower Right Corner Menu > select Analysis Tools > Multiplication (or) Favorite Tools area > Multiplication Icon • Create Multiplication dialog box opens • Factors – Select Phases or Series • Use Constant – set Value (e.g., only if needed) • Result Series > Enter Name • Select OK – Starts Multiplication • Multiplication Series – displayed in Series Panel and Result Segments of Layout Create Multiplication ? X 1 Settings MR Multiplication Settings Config. 2 3 Factors angio_fl3d_cor_pre.latest angio_f13d_cor_post.latest Create Multiplication 1) Settings – name Current Active Setting 2) Config Icon – opens Multiplication Settings dialog 4 window Use Constant 14 5 Remove 3) Factors – Phases or Series 6 Result Series Name 4) Use Constant – set Value Results MUL_angio_f1 3d_cor_pre_C1 5) Remove – removes Factors 6) Result Series Name – default name is freely editable OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 20 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Division • Division Options • Divide images or a set of series by a constant value • Divide series by series • Divide a series by one image • Division Workflow • Depress Ctrl Key > select Segments for Division • Lower Right Corner Menu > select Analysis Tools > Division (or) Favorite Tools area > Division Icon • Create Division dialog box opens • Dividend – Select Images or Series • Divisor – Select Phases or Series • Use Constant – set Value (e.g., only if needed) • Result Series > Enter Name • Select OK – Starts Division • Division Series – displayed in Series Panel and Result Segments of Layout Create Division ? X 1 Settings MR Division Settings 2 Config. Create Division 1) Settings – name Current 3 Dividend angio_fl3d_cor_post.latest Active Setting 2) Config Icon – opens Division Settings dialog window 3) Dividend – Phases or Series 4) Remove – removes Dividends 5) Divisor – Phases or Series Remove 4 6) Use Constant – set Value 5 Divisor angio_f13d_cor_pre.latest 7) Result Series Name – default 6 Use Constant name is freely editable Result Series Name Results DIV_P1_angio_fl 3d_cor_post 7 OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 21 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Apparent Diffusion Coefficient (ADC) – mobility of molecules in certain tissue types • ADC Maps – calculated for diffusion-weighted images and require measurements with various diffusion weightings (b-values) • Higher b-value – stronger diffusion weighting • Calculating ADC maps and Computed b-values Workflow Favorite Tools X • Select Diffusion Series 3D • Lower Right Corner Menu > select Analysis Tools > ADC Show in TimeCurve ADC & b- Compose/ 3D value Combine & b-value (or) Favorite Tools area > ADC & b-value Icon • ADC & b-value dialog box opens • ADC Map Calculation • Input Series > Clear Check Boxes for b-values not required for calculation • Threshold (Recommendations) – optimize results of ADC map and b-value • Neuro = 40 • Body = 10 • Computed b-value Images • Enable Computed b-value –check box • b-value slider – move slider to adjust (or) enter b-value • Result Series > Enter Name ADC & b-value ? X • Select OK – Starts Calculation and Saves Results ADC Map Calculation • ADC & b-value Series – displayed in Series Panel and Result Segments 1 nput Series Vresolve_3scan_trace_tra_192_p2_TRACEW of Layout B-Value_01_0 B-Value_02_1000 2 Threshold 10 + Remove 3 ADC & b-value 4 Result Series Name Results ADC_bo_1000_resolve_3scan_trace_tra_192 1) Input Series – select series required for Computed b-value images calculation Enable Computed b-value 2) Threshold – enter value to optimize ADC p-value 1400 M Auto Preview map & b-value 3) Remove – removes Input Series 6 Result Series Name Results CALC_b1400_b0_1000_resolve_3scan_trace_ 4) ADC Map Result Series Name – default name is freely editable 5) Enable Computed b-value – adjusts b-value 6) Computed b-vaule Images Result Series Name – default name is freely editable OK review Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 22 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Arithmetic Mean – Calculate the mean value of the grayscale, to average large intensity differences in images. • May improve the signal-to-noise ratio or reduce image artifacts • Arithmetic Mean Workflow • Depress Ctrl Key > select Segments for Arithmetic Mean • Lower Right Corner Menu > select Analysis Tools > Arithmetic Mean • Arithmetic Mean Dialog Box opens • Input Series >Clear Check Boxes for series not required for calculation • Slider – define calculation range • Note: Useful when handling large amounts of input data (several time points). Input data can be split up to create several result series (i.e., mean value series can be created for time point 1 to 6, and then for time point 7 to 13) • No.of Output Images – number of mean value images • Result Series > Enter Name • Select OK – Starts Arithmetic Mean calculation o Arithmetic Mean Series – displayed in Series Panel and Result Segments of Layout Arithmetic Mean ? X 1 Input Series Vangio_f13d_cor_pre.latest angio_f13d_cor_post.latest Arithmetic Mean 1) Input Series – select series required for calculation 2) Arrows – moves input series up or 2 - 3 Remove down Use slider for selection of input series for calculation 3) Remove – removes Input Series 4) Slider – define calculation range 4 -O 5) No of Output Images 6) Result Series Name – default 5 No. of Output Images name is freely editable 6 Result Series Name Results MEAN_angio_fl3d_cor_pre OK Cancel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 23 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Auto Windowing – window width and center values are automaticall calculated Auto Windowing auto • Select Auto WIndowing MR Presets • MR Presets – predefined window values • Configured for Modality Type and Scanned Organ p3 MINORMID • Lower Right Corner Menu > select MR Presets ADC_MAP F5 A1/PFP • All available Presets shown BO2,3;801-3:S. B VAL F6 • Note: Windowing presets can be assigned to function keys *f13d1 / 21 (F5 to F8). DYN F7 • Preset Set-up SUB|MIPIMIP_THIN F8 • Point to Window Preset in Bottom Right Corner Menu > select Settings Icon > choose Function Key MR_Angiography STIR Germany MAC from Context List *1/1/1962, M. 55Y CURRENT SUB 7/26/2017 T2 • MR Color LUT – look-up table defines sequence of colors Inverted Grayscale Shift+F5 • Color LUT Applied to Grayscale Image – intensity of individual Hot Body Shift+F6 pixels transformed into a color according to color sequence in Warm Metal Shift+F7 X LUT MR_Aof Metal Shift+F8 • MR Color LUT Workflow Germany_MAC *1/1/1962, M. 55Y • Lower Right Corner Menu > select MR Color LUT Grayscale CURRENT 7/26/2017 All Availlable entries for image type shown Perfusion • angio_113d corsa Choose a Color LUT latest Heart • # XA10 (or) STUDY ID 3aaa Hot Iron 9001 IMAG ........... • Color LUT already applied > select Invert Hot Metal New R • Applies negative Color LUT Parathyroid ............ • F9 – Toggles through all color LUTS Rainbow TR 2.6 TE 0.9 Red TA 12.47 BW 723.0 Spectrum p3 M/NORM/DIS2DA A1/PFSpectrum 10 Step BO2,3;801-3:840 *113d1 / 21 Grays ASIST Perfusion Invert F10 • Reset Windowing – applied window values are not as expected, restores original window values to when data was Reset Windowing loaded initally to View&GO. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 24 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 • Context Menus – access to functions corresponding to current work situation • Configure Context Menu – configure context menu to quickly access Corner Menu favorite tools • Open Context Menu • Select Image segment > Right-Click > opens Context Menu • Add Tool to Context Menu • Select Watermark in any Corner Segment • Select Tool > Right-Click select Send to Context Menu • Rearrange Tools in Context Menu • Depress Left Mouse > Drag Tool to New Position in Context Menu • Remove Tool from Context Menu • Select Tool in Context Menu • Depress Left Mouse > Drag Tool out of Context Menu HRA MR_Oncology SPITALUL CLINIC SANADOR Romania_MAC Ref.: Congress *1/1/1964, F, 51Y CURRENT T Text Skyr MR E11 11/13/2015 HFS Clip Box +LPH t1_tirm_sag_dark-flu latest Fit to Segment # VE11 STUDY ID 2aaaa0918 ROI Circle 20 IMA 23 AL 3D Reference Point Distance Line L TI 900.0 TR 2000.0 is Marker m TE 9.0 TP F13 TA 01:02*3 SP L1.0 ADC & b-value BWV 260.0' FoV 240*240 p3 M/NORM/DIS2D 256*320 [I] Exclude Time Point Sag>Tra(-3)>Cor(-1) A1/IR Zoom 1.53 HC1-7;NC1,2 Insert and Propagat W 1176 *tir2d1 -- 4/150 586 3D Show in 3D Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 25 of 26 Job Aid | MR View&GO Corner Menus Effective Date: 06/24/2021 | HOOD05162003199248 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/24/2021 | HOOD05162003199248 Healthineers Page 26 of 26