Multifunctional Wireless Footswitch on the Cios Spin
This PDF provides an overview of the optional multifunctional wireless footswitch.
Multifunctional Wireless Footswitch (Option) Job Aid Cios Spin The optional multifunctional wireless footswitch offers the same functions as the standard footswitch and the multifunctional wired version, such as radiation release and image storage. The following image shows the standard configuration of the multifunctional wireless footswitch. Please note that the layout and functionality assigned to the foot pedals can be configured in the Service Software, and therefore can deviate from the standard configuration. 5 4 6 7 3 MODE 2 . MODE 1 8 No. Description No. Description 1 Left pedal 5 Rotary knob of battery compartment Radiation release for selected operating mode 2 Battery status LED 6 MODE button 3 Connection status LED 7 Stirrup 4 Save button 8 Right pedal Stores images or scenes Radiation release for fluoroscopy Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/14/2020 | HOOD05162003087824 Healthineers Job Aid | Multifunctional Wireless Footswitch (Option) Effective Date: 05/14/2020 | HOOD05162003087824 States of the Status LED No. Subject Modes Battery status LED • Green: Battery full or nearly full Battery capacity • Orange: Battery almost full The battery capacity is also shown on • Orange (flashing): Battery low the left monitor’s status bar. Connection status LED • Green: Connection active Radio link or pairing mode • Orange: No connection active • Orange (flashing): Footswitch not paired • Green and orange alternately flashing: Pairing mode activated Battery status LED + • Orange (both LEDs flashing): Fatal Connection status LED system errors (for example, battery Fatal error or footswitch update exhausted or memory error) • Green and orange (both LEDs alternately flashing): Firmware update process running Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/14/2020 | HOOD05162003087824 Healthineers Page 2 of 7 Job Aid | Multifunctional Wireless Footswitch (Option) Effective Date: 05/14/2020 | HOOD05162003087824 Switch on the Wireless Footswitch Take the wireless multifunctional footswitch out of the footswitch holder. o- Place it horizontally on the floor. This will switch on the footswitch automatically. Swivel the stirrup into the upright position until it locks. The footswitch is now ready to use. The footswitch automatically switches to standby mode if it is not used for a certain period of time. Activate it again by pressing any button or pedal. Selecting the Operating Mode If necessary, press the MODE button several times to select one of the operating modes: Single image, Fluoro, SUB, Roadmap or a video source (depending on the available operating modes). CMODE The selected operating mode is indicated in the Examination Orb. 0' Ang. 0 task card and on the control panel of the C-arm system. 68 A confirmation sound acknowledges successful operating 00:00:00 17 himniss MA mode/video source switchover. You can release radiation again right away. PROCESSING EXTERION Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/14/2020 | HOOD05162003087824 Healthineers Page 3 of 7 Job Aid | Multifunctional Wireless Footswitch (Option) Effective Date: 05/14/2020 | HOOD05162003087824 Release radiation The functionality of the pedals can optionally be changed. The information provided in this document refers to the default settings. Use the right pedal to activate Fluoroscopy. Keep the foot pedal pressed during radiation release. MODE CMODE Press the left pedal to activate the currently selected operating mode. Exception: If Fluoroscopy (CFC) mode is selected, the left pedal MODE is assigned as Single Image operating mode. In this case, keep pressing the pedal until the radiation stops automatically. Store images Press the save button on the multifunctional footswitch. () woce • Last image hold (LIH): Hold the key for less than two seconds to save the image last recorded. -MODE • Last scene hold (LSH): Hold the key for more than two seconds to save the scene last recorded. The images are stored in the local database. They are transferred from the left monitor to the right monitor unless the Hold reference function is active. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/14/2020 | HOOD05162003087824 Healthineers Page 4 of 7 Job Aid | Multifunctional Wireless Footswitch (Option) Effective Date: 05/14/2020 | HOOD05162003087824 Replace the batteries 1. To open the battery compartment, lightly press in the knob and turn it counterclockwise. 2. Remove the batteries. 3. Insert new batteries (LR14) into the footswitch. + + HI 4. To close the battery compartment, insert the knob into the depressions. Press lightly and turn it until it clicks into O place. Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/14/2020 | HOOD05162003087824 Healthineers Page 5 of 7 Job Aid | Multifunctional Wireless Footswitch (Option) Effective Date: 05/14/2020 | HOOD05162003087824 Secure the Footswitch for Transport For secure storage and transportation of the footswitch, insert the footswitch into the holder on the front of the C-arm system. Ensure that the colored symbols on the footswitch are lined up with the ones on the holder to avoid inserting the wrong footswitch. The following colored symbols are used for unique allocation of the footswitch to the holder: + Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/14/2020 | HOOD05162003087824 Healthineers Page 6 of 7 Job Aid | Multifunctional Wireless Footswitch (Option) Effective Date: 05/14/2020 | HOOD05162003087824 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/14/2020 | HOOD05162003087824 Healthineers Page 7 of 7
- cios
- spin
- footswitch
- wireless