PEPconnect

Multitom Rax Turnover Workbook

Multitom Rax Turnover Workbook

SIEMENS SIEMENS User Services www.usa.siemens.com/education Multitom Rax Turnover Workbook Answers for life. User Services. Driven by More. More: Our philosophy for a lifelong improvement through continuing education and consulting. Working closely with you, we develop your personalized education and consulting strategy and support you and your staff with our comprehensive User Services to help gain: • More: Routine Confidence • More: Clinical Expertise • More: Superior Performance More: Personalized training, education, and consulting services from Siemens Healthcare Customer Services. For your leading edge in medical care. User Services. Driven by More. More: Personalized More: More: Superior Clinical Performance More: Routine Expertise Confidence 2 I Contact Information Summary Welcome to Siemens Healthcare Clinical Education Offerings: Siemens Healthcare is dedicated to helping you Call 1-888-221-8010 (follow the prompts) • get the most out of your investment throughout Classroom Training the entire product life cycle and beyond. Our goal (Offerings, Registration & Scheduling) • is to enable you to take technology further, Educational Symposia • profitability higher, and patient care to the next On-site Training • level. Find the information, resources, and tools Printed Self-studies • you need to get the most out of your recent Virtual Education (Offerings & Registration) • investment and stay up-to-date. Visit Workshops & Fellowships www.usa.siemens.com/Welcome2Healthcare. Visit www.usa.siemens.com/education for more information regarding the current Clinical Training and Siemens Clinical Training and Continuing Continuing Education Education portfolio. Siemens Customer Care Center: Call 1-800-888-7436 Siemens Training Centers • Troubleshooting assistance Immediate assistance for software Siemens Clinical Education • applications and workflow issues Training Center – TDC2 • For Tech Support press option 2 / for 110 MacAlyson Court applications support, press option 3 Cary, NC 27511 • Press the * key or enter the last six digits of your Functional Location Number Functional Location Number ____________________ Serial Number ________________________________ IP Address System _____________________________ IP Address PACS _______________________________ 3 II Contents I Contact Information Summary ............................................................................................... 3 II Contents .............................................................................................................................. 4 III Course Agenda .................................................................................................................... 5 IV Course Objectives ................................................................................................................ 6 1. Day One: System Introduction and Startup............................................................................ 7 1.1 Objectives .................................................................................................................... 7 1.2 System On/Off.............................................................................................................. 7 1.3 Tube Stand Movement Buttons ...................................................................................... 8 1.4 Detector Stand Movement Buttons ................................................................................ 8 1.5 Emergency Stop Buttons ............................................................................................... 9 1.6 Table Top.................................................................................................................... 10 1.7 PEX Editor .................................................................................................................. 10 1.8 Stand Positions ........................................................................................................... 14 2. Day Two: System Training Continued .................................................................................. 15 2.1 Objectives .................................................................................................................. 15 2.2 Room Review.............................................................................................................. 15 2.3 Wireless Remote Control ............................................................................................. 15 2.4 Fluorospot Compact (FLC) Training .............................................................................. 17 2.5 Tube Stand with MAX Touch User Interface .................................................................. 23 2.6 Remote Control Console (RCC) with TUI ....................................................................... 24 2.7 Perform Patient Exams ................................................................................................ 28 3. Day Three: Review and Ortho Training* .............................................................................. 29 3.1 Objectives .................................................................................................................. 29 3.2 Review ....................................................................................................................... 29 3.3 Ortho Package Training*............................................................................................. 29 3.4 Perform Patient Exams ................................................................................................ 29 4. Day Four: Review ............................................................................................................... 30 4.1 Objectives .................................................................................................................. 30 4.2 Review ....................................................................................................................... 30 4.3 Perform Patient Exams ................................................................................................ 30 5. Day Five: Review................................................................................................................ 31 5.1 Objectives .................................................................................................................. 31 5.2 Customer Care Center................................................................................................. 31 5.3 Review ....................................................................................................................... 31 5.4 Checklist .................................................................................................................... 31 Appendix A: Multitom Rax Siemens Radiography Trainer to Trainee Checklist............................ 33 4 III Course Agenda Day One Introduction to basic system workflow Storing stand positions Protocol customizations Day Two Day one review Wireless remote control Fluorospot Compact Tube Stand Touch User Interface Perform patient exams Day Three Perform patient exams Review system Q&A Ortho package and options (if applicable) Image quality review Day Four Perform patient exams Review system Day Five Perform patient exams Q&A Intro to Customer Care Center 5 IV Course Objectives Course Overview: This training guide will enable the end user to affectively operate the Multitom Rax at its optimal level. Proper use of system functions and features will empower operators with precise workflow, quick patient through put and user satisfaction. Upon completion of this course, you will be able to: • Correctly perform start-up and shutdown procedures. • Identify the key hardware features of the Multitom Rax system. • Utilize the FLUOROSPOT Compact imaging system. • Utilize postprocessing functions to optimize image impression. • Troubleshoot common issues. 6 Turnover Workbook | Multitom Rax 1. Day One: System Introduction and Startup 1.1 Objectives Notes By the end of this section, the technologist will be able to: • Turn the System On/Off • Utilize the Tube/Detector Stand buttons • Identify the Emergency Stop Buttons • Table top Functions • Basics of the PEX Editor • Storing Stand Positions 1.2 System On/Off The system is turned On/Off by selecting the corresponding button on the Remote Control Console (RCC). STOP WARNING! THIS X-RAY UNIT MAY BE DANGEROUS TO PATIENT AND OPERATOR UNLESS SAFE EXPO- SURE FACTORS, OPERATING INSTRUCTIONS AND MAINTENANCE SCHEDULES ARE OBSERVED. P A daily re-boot of the system is recommended. 7 Turnover Workbook | Multitom Rax 1.3 Tube Stand Movement Buttons Notes (1) (5) (2) (6) (3) (7) (4) Els (8) # 20 cm H ACSS # 20 cm 3 (1) Rotation Around Vertical Access (2) Longitudinal Tube Movement (3) Vertical Tube Movement (4) Detector to Tube Centering/Rax Align (5) Rotation Around Horizontal Access (6) Transverse Tube Movement (7) Horizontal Float Only (8) Three Directional Tube Float 1.4 Detector Stand Movement Buttons • Rotation Around Horizontal Access (RHA) • Rotation Around Transverse Access (RTA) 8 Turnover Workbook | Multitom Rax Notes • Manual Vertical Movements • Tube to Detector Centering/Rax Align • Motorized Vertical Movements T 1.5 Emergency Stop Buttons STOP • Table Side Locations • Wall Locations • Remote Control Console • When pressed all motor driven system movements are interrupted. • Active radiation will be interrupted; to initiate radiation again step off and back on the desired foot pedal. 9 Turnover Workbook | Multitom Rax 1.6 Table Top Notes • The table top is 3 meters long, and weighs approximately 58 lbs. • The Max patient table weight is 529 lbs. • The table top can be removed if not required for the examination. • Hand grips can be attached to the table for patient safety. 1.7 PEX Editor Opening the PEX Editor • On the Patient Task Card > Settings Subtask Card, select this icon: • The Logon Screen will appear Programs and Exam Editor • Select the radio button next to Siemens. • Enter the password the Applications Specialist gave, and select OK. Programs and Exams Editor Login Viewing only Customer SIEMENS Password ....... Ok Ok Java Java is a registered trademark of Oracle and/or its affiliates 10 Turnover Workbook | Multitom Rax Exam Tab Notes • The PEX Editor opens up to the Exam subtask card. Exam Organ Program Fluoro Program Param. Module Configuration OGP View Examination View 9_Peri_Template (d) ABDOMEN 3 VIEWS_S(d) C Abdomen, left side pos. (d) ABDOMEN FLAT & UPRIGHT_S(d) C C-spine lat (d) ABDOMEN KUB_S(d) C Femural neck axial (d) Insert OGP T ABDOMEN SUPINE (d) C Hip (d) X ABDOMEN SUPINE (d) C Hip, with grid (d) T ABDOMEN (8-13cm) (d) C Humerus lat (d) T ABDOMEN (14-19cm) (d) C Patella tangential (d) T ABDOMEN (20-25cm) (d) C Pelvis (d) L XTL ABDOMEN DECUB (d) C Pelvis, with grid (d) CR (d) C Portable lung (d) ABDOMEN UPRIGHT VIEW ONLY_S(d) C Portable lung, with grid (d) Remove OGP ABDOMEN-ACUTE INCL PA CHEST_S( C Shoulder (d) ABDOMEN-DECUBITUS_S(d) ..... C Shoulder axial (d) ABDOMEN-LATERAL ONLY_S(d) C Zygomatic arch (d) ACROMIOCLAVICULAR JOINTS BIL_S( Group by Name Body Part @ Acq. type Sort by O Name Body Part Acq. type Exam Parameters Default Exams OGP Parameters ExamName ABDOMEN KUB_S Name for RIS ABDOMEN KUB_S DICOM Modality Add to favorites Filming Layout Favor B Network Node 1 Default Network Node Exam level OGP level Network Node 2 Fluoro Network Node 3 Rad Camera Default camera O Auto Scale Auto Stale Autosending Never for this exam % Automatically switch to next OGP after acquisition Store as new Store Delete Close Entering Exam Names Exan Organ Program Fluoro Program Configuration OGP View Examination View 9_Peri_Template (d) ABDOMEN 3 VIEWS_S(d) C Abdomen, left side pos. (d) ABDOMEN FLAT & UPRIGHT_S(d) C C-spine lat (d) ABDOMEN KUB_S(d) ...... C Femural neck axial (d) Insert OGP T ABDOMEN SUPINE (d) C Hip (d) X ABDOMEN SUPINE (d) C Hip, with grid (d) T ABDOMEN (8-13cm) (d) C Humerus lat (d) T ABDOMEN (14-19cm) (d) ..... C Patella tangential (d) T ABDOMEN (20-25cm) (d) C Pelvis (d) L XTL ABDOMEN DECUB (d) C Pelvis, with grid (d) CR (d) C Portable lung (d) ABDOMEN UPRIGHT VIEW ONLY_S(d) .... ABDOM C Portable lung, with grid (d) ABDOMEN-ACUTE INCL PA CHEST_S( C Shoulder (d) Remove OGP ABDOMEN-DECUBITUS_S(d) .... C Shoulder axial (d) ABDOMEN-LATERAL ONLY_S(d) C Zygomatic arch (d) ACROMIOCLAVICULAR JOINTS BIL_S( - Group by O Name . Body Part @ Acq. type Sort by Name Body Part Acq. type Exam Parameters Default Exams OGP Paramete ExamName ABDOMEN KUB_ Name for RIS ABDOMEN KUB_S DICOM Modailly Add to favorites Filming Layout Network Node 1 Default Network Node Exam leve OGP level Network Node 2 Network Node 3 Rad Camera Default camera O Auto Scale OAuto Scale Autosending Never for this exam % % Automatically switch to next OGP after acquisition Store as new Store Delete Close • The Examination View is located on the right side of the screen in the Exam tab. • This is where the names can be created or modified to match the RIS Exam Names (a copy of the RIS Exam Names should be supplied by the site). • Left Click on an Exam name that is similar to the name in the RIS worklist. • Populate the Name for RIS field, with the name from the RIS list, then copy and paste this name into the Examination View field (Control C to copy and Control V to paste). • Use “Store” if the name was modified and “Store as New” if a new name is created. 11 Turnover Workbook | Multitom Rax Modifying or Creating Organ Programs Notes • The OGP View is on the left side of the screen in the Exam Tab. This is where organ programs can be modified or created. • When creating or modifying Organ Programs, be mindful to pick the correct prefix. • C = Cassette Exposure (CR or Film) • T = Table Exposure (Detector under table) • W = Wallstand Exposure (Wall position) • V = Free Exposure (Detector Stand) • X = Free Exposure* (Wireless Detector) • Fluoro = Fluoroscopy Mode • DSA = Subtracted Imaging/Roadmap* • OW/OT = Ortho Imaging* (In table mode or wall mode) • L=Cross tabel Exposure • Double left click on the Organ Program to be modified. • The Organ Program subtask card will open. • In the Program Name field, remove the (d) and enter the new or modified name. • Adjust any Exposure Parameters/Settings, and select Store for modifying or Store as New if a new Organ Program is created. Exam Organ Program Fluoro Program Param . Module Configuration Body Part Examined ABDOMEN Alternative Acquisition Programs Program Name T ABDOMEN SUPINE (d) X ABDOMEN SUPINE (d) Y X ABDOMEN DECUB (d) W ABDOMEN UPRIGH ... Acquisition Mode DR RAD Acquisition Type Table X - Ray Parameters Image Processing Parameters Presettings Mark Image Auto-cropping Standard Set Black Fluoro Program Set CP_RAD_Po ... PT Position Not defined Defined size as cropped MField III Laterality Not Defined Amplification 2.0 Auto Enhanced MField View position Not Defined 1 pt Gradation Parameters Anatomically Correct View 1 pt with ext. exp. Flip 2 pt 13 Spine/Abdomen No change 13 pt Invert (Image) R 3 pt with AEC Spatial Frequency Parameters KV 81 v votate 90 180 @ 270 O MAS Abdomen Label XI Value LO R Exp. Correction 0 EP default Dose 2.5 Sensitivity 400 Windowing Stand Parameters Tube Load 80 % Width Factor Center Shift V Auto TOD not defined Focus cm Filter Type 0.0 Cu mm Window Center 2000+ Grid 115v cm Grid rotation Window Width 2500 + Collimator 16,93 × 16.93 inches Stand Position Table position Top Alignment V SID Tracking Tracking Anatomic order number 0 Store Store as new Print previous next Close * Option 12 Turnover Workbook | Multitom Rax Adding an OGP View to Examination View Notes Exam Organ Program Fluoro Program Param . Modul Configuration OGP View Examination View T ABDOMEN (20-25cm) (d) 0_Pex Database_OCT2015_G1_ROW(I - T ABDOMEN (8-13cm) (d) 0_RAD_Daily_Check(d) .... T ABDOMEN BARIUM AP (d) 0_Siemens CSE Test Programs(d) T ABDOMEN BARIUM PA (d) 1_Position_Setup ..... T ABDOMEN IODINE (d) Insert OGP ABDOMEN 3 VIEWS_S(d) T ABDOMEN LATERAL (d) ABDOMEN FLAT & UPRIGHT_S(d) T ABDOMEN OBLIQUE (d) ABDOMEN KUB_S(d) T ABDOMEN PEDS BARIUM AP (d) T ABDOMEN SUPINE (d) T ABDOMEN PEDS IODINE (d) X ABDOMEN SUPINE (d) 44444 T ABDOMEN SUPINE (d) T ABDOMEN (8-13cm) (d) ..... T ABDOMEN UPRIGHT (d) T ABDOMEN (14-19cm) (d) ..... T AC JOINTS (d) T ANKLE 0-3yrs (d) Remove OGP T ABDOMEN (20-25cm) (d) L XTL ABDOMEN DECUB (d) T ANKLE 4-12yrs (d) CR (d) T ANKLE AP (d) ABDOMEN UPRIGHT VIEW ONLY_S(d) Group by Name Body Part Acq. type Sort by O Name Body Part Acq. type Exam Parameters Default Exams OGP Parameters ExamName ABDOMEN KUB_S Name for RIS ABDOMEN KUB_S DICOM Modality Add to favorites Filming Layout Network Node 1 Default Network Node Exam level OGP level Network Node 2 Fluoro Network Node 3 Rad Camera Default camera Auto Scale O Auto Scale Autosending Never for this exam % % Automatically switch to next OGP after acquisition Store as new Store Delete Close • Highlight the desired Examination View and highlight the OGP View to be added, select Insert OGP. To remove OGP Views, highlight the OGP View from the desired Examination View and select Remove OGP. • The order of the OGP Views can be adjusted, using the up/down arrows. • The check box for, automatically switch to next OGP after acquisition allows the next view to populate automatically. Select Store to save this function per OGP View. Backup PEX Editor • After changes to the PEX Editor, a backup is necessary. • While in the PEX Editor, select the Configuration tab. • Select Backup/Export • Select the C or D drive and Go to back up the PEX Editor to the local hard disc (each drive can hold ten backups). 13 Turnover Workbook | Multitom Rax 1.8 Stand Positions Notes • Each Organ Program will have a stand position assigned to it. The exact location of the position in the room will be configured in the PEX Editor. Each stand position may be used by multiple Organ Programs. Storing Stand Positions In the PEX Editor • Set up the system in the desired location in the room. • Select the Parameter Module tab in the PEX Editor. Exam Organ Program Fluoro Program Param . Module Configuration Body Part Examined Stand Position ABDOMEN Identifier $005 Name Delete Table position Store New Collimator settings Ignore for auto-cropping Position: Assigned EXI Values Identifier Store Position tore Parameters Name Min. EXI Delete Activate New Max. EXI Target EXI Spatial Frequency Parameters Delete Store Gradation Parameters Identifier Name Name Diamond View ID 00 Shape 0 Diamond View Name Off Contrast 0.14 Noise Reduction Center 1 Edge Filter: Kernel 3 Offset -2048 Edge Filter: Gain -16 Harmonization: Kernel 3 Delete Store New Harmonization: Gain 0 Trajectory Import Delete Store New Close • In the Stand Position Section (top right), select the desired stand position from the “Name” field. • Select “Store Position” (confirm override of previous stand position) Assigning Stand Positions to Organ Programs • In the Exam tab double left click on the Organ Program to be modified. • In the Stand Parameters section (bottom right), select the desired Stand Position from the drop down and select Store. 14 Turnover Workbook | Multitom Rax 2. Day Two: System Training Continued 2.1 Objectives Notes By the end of this section Technologist will be able to: • Review and use the wireless Remote Control • Utilize the Fluoro Spot Compact and all corresponding tabs • Utilize the Tube Stand and TUI • Remote Control Console and TUI • Utilize room for patient exams 2.2 Room Review 2.3 Wireless Remote Control • The Wireless Remote has an approximate range of 5 meters around the receiver mounted to the stand. • Charging time is approximately 2 hours. • Operating time with a full battery is approximately 12 hours. Display area Operation area # Selection area • Dead-Man Switch must be pressed to facilitate system movements. Dead-man switch 15 Turnover Workbook | Multitom Rax • Remote RHA Buttons Notes • Remote RVA Buttons • Remote Transverse Adjustments • Remote Longitudinal Adjustments • Remote Move to OGP Position • Remote Vertical Adjustments • Remote Detector Center Tracking enable/disable • Remote SID Tracking enable/disable • Remote Activate Park Position • Remote Charging Station 16 Turnover Workbook | Multitom Rax 2.4 Fluorospot Compact (FLC) Training Notes Attaching a detector • The Max Detector Overview page must be open on the FLC. Detector overview MAX dynamic MAX WI-D MAX min Serialnumber 1307H6 131783 Calibrason due 10-02-2017 10-02-2017 10-02-2017 Default Disconnect Discorrect • Hold the detector with the LED’s facing the infrared sensor on the upper right corner of the Fluorospot Compact. SIEMENS • All of the LED’s on the detector will start to blink orange, then green. • When the LED’s stop blinking, the detector can be taken away • The following message will display on the FLC. Detector attachment Detector ALREADY attached. Do you want to attach it again? Detector type:MAX wi-D, Serial number: 160936. Yes Cancel 17 Turnover Workbook | Multitom Rax Patient Tab Notes • Pre-Registered and Examined Patient Tabs • Patient Subtask Card Patient Settings Service + == = 0 RIS RIS • Settings Subtask Card Patient Settings Service ?F EXI • Service Subtask Card Patient Settings Service 18 Turnover Workbook | Multitom Rax Examination Tab Notes • Patient and Resource Information SIEMENS, SIEMENS 11-11-1999 uGym2 Patient 0.00 C *T ABDOMEN (8-13cm) T ABDOMEN (14-19cm) T ABDOMEN (20-25cm) T ABDOMEN (26-31cm) Examination Fluoro Rad - 16.6 " x 16.6 " 41.6 Post 8 Current Target none • Fluoro Subtask Card Examination Fluoro Rad Postprocessing 0 7.0 s CP_Pediatric Series DSA p/s 3 2 KV 0 KV 73 mA 0.0 mAs Documentation ms ms Dose 3.48 min 000.0 0.0 mm Cu 0.3 mm Cu 0.0 30 p/s Focus mGy/min % = 2 Gy 0.0 mGy 1.1 • Rad Subtask Card Examination Fluoro Rad Postprocessing CP_RAD_Position RAD p/s 3 KV 0 KV 70 Documentation mA 0.0 mAs 2.8 ms 0.0 ms min 000.0 Dose mm Cu 0.2 mm Cu 0.0 30 p/s FOCUS mGy/min 96 < 2 Gy 0.0 mGy 0.0 19 Turnover Workbook | Multitom Rax PostProcessing Tab Notes • Process Subtask Card T ABDOMEN (26-31 cm) Examination Process. Graphics Rad D-0 R R Postprocessing R 0- • Graphics Subtask Card T ABDOMEN (26-31cm) Examination Process. Graphics Rad Postprocessing • Rad Subtask Card T ABDOMEN (26-31 cm ) Examination Process. Graphics Rad Auto-cropping Set black Auto-window Amplification 0.5 Auto Postprocessing as cropped 20 Turnover Workbook | Multitom Rax Notes • DSA Subtask Card* CR VOSA TABLE PEDIATRIC_2fp: Examination Process. Graphics DSA MI Jopac % Postprocessing @XYZ D • Image Subtask Card tation KV 0 KV 73 mA 0.0 mAs min 000.0 ms Image Tools • Tool Subtask Card Intation KV KV 70 mA 0.0 mAs 2.8 min 000.0 ms Image Tools >>REF *Option 21 Turnover Workbook | Multitom Rax • Documentation Tab Notes • Select Subtask Card Examination Select Film Send X processing Documentation KV KV 73 mA 0.0 MAS • Send Subtask Card camination Select Film Send Target Target 2 Target 3 Postprocessing Send Exam Protocol as: SCimage DICOM Dose SR Override configured settings Documentation ? KV 0 KV 73 MA 0.0 MAS 22 Turnover Workbook | Multitom Rax 2.5 Tube Stand with MAX Touch User Interface Notes Tape Measure Tab • SID Measurement 8 • SOD Measurement 8 • Magnification display (SOD Mag = SID/SOD) Generator Tab • Exposure Parameters • Home Button Device Position Tab • Zero degree detent On/Off • Tube Rotation Horizontally/Vertically • Detector RHA/RTA • Max Align* 50ª • Combined Angulation Setup Tab • Block Movement/block Radiation • CAREPOSITION On/Off* • Stand Movement Speed *8* *Option 23 Turnover Workbook | Multitom Rax 2.6 Remote Control Console (RCC) with TUI Notes Hardware Functions DE STOP WARNING! THIS X-RAY UNIT MAY BE DANGEROUS TO PATIENT AND OPERATOR UNLESS SAFE EXPO- SURE FACTORS, OPERATING INSTRUCTIONS AND MAINTENANCE SCHEDULES ARE OBSERVED. P -O * 100 - • Collimation Adjustments # # # • Tube Angulation • Orbital Movements • Main Joystick 24 Turnover Workbook | Multitom Rax Notes • Exposure with Rotor • Room Lights (If configured) • SID Adjustments • Room On/Off • Emergency Stop STOP • Park P • Patient Transfer • Slow/Fast OGP Position Touch User Interface (TUI) • The TUI is split into three main sections; Fluoro Settings, Acquisition Settings, and the Image/Tools/Setup Subtask Cards. • Header Information is always displayed at the top • Footer Information is always displayed at the bottom 25 Turnover Workbook | Multitom Rax Fluoro Settings Notes 70 0.2 mit Cu 80 V 3.5 7.5 min pis • Automatic Fluoro Program 1,2, or 3 • Automatic Fluoro Stop • Reset Fluoro Alarm • Store Fluoro Loop • Fluoro Pulse Rate Selection Acquisition Settings + 70 • Exposure Parameters • Frame Rate Selection • Series On/Off • Restore Original Values (Home) • “+” Button (Show More Parameters) 26 Turnover Workbook | Multitom Rax Image Subtask Card Notes Image Tools Setup • Image navigation • Start/Stop Loop • Last Image Hold LIH • Display Overview Tools Subtask Card Image Tools Setup 0. # ta Da cy LAr • Image Navigation • Mark/Unmark Image • Set L/R Label • Magnification • Lock Collimation • DSA Functions* *Option 27 Turnover Workbook | Multitom Rax Setup Subtask Card Notes Image Tools Setup R RA DVD • Flip Horizontal/Vertical • Reverse Transverse/Longitudinal Movement • Block Movement/Block Radiation • DVD Recording • CAREPosition* 2.7 Perform Patient Exams *Option 28 Turnover Workbook | Multitom Rax 3. Day Three: Review and Ortho Training* 3.1 Objectives Notes By the end of this section Technologist will be able to: • Review Ortho Package and Options • Utilize room for patient exams 3.2 Review 3.3 Ortho Package Training* System Set Up • Tube/Detector Ortho Tab* • TOD 10.5 cm • Set Position one (Start Position) • Set Position two (End Position) V Auto Composing • Manual Adjustments 3.4 Perform Patient Exams *Option 29 Turnover Workbook | Multitom Rax 4. Day Four: Review 4.1 Objectives Notes By the end of this section Technologist will be able to: • Utilize room for patient exams 4.2 Review 4.3 Perform Patient Exams 30 Turnover Workbook | Multitom Rax 5. Day Five: Review 5.1 Objectives Notes By the end of this section Technologist will be able to: • Utilize room for patient exams • Review Checklist 5.2 Customer Care Center • To Contact the Customer Care Center dial 800-888-7436, then follow the prompts to route you to Applications or Technical Support. 5.3 Review 5.4 Checklist 31 Workbook | Workbook Name Notes 32 Appendix A: Multitom Rax Siemens Radiography Trainer to Trainee Checklist 33 Multitom Rax Siemens Radiography Trainer to Trainee Checklist ***This checklist is not accredited for Continuing Education Units*** General Information Trainer Name: Trainee Name: Training Dates: Topic Trainer Trainee Initials Initials Time In Room Equipment Emergency Stop Buttons Wireless Detectors* Detector Stand Rax Align Stand Movements Grids Tube Stand Stand Movements Max Touch Screen Patient Table Removal Table Controls Wireless Remote Control Remote Control Console Touch User Interface (TUI) Hardware Controls Fluorospot Compact Computer System: Patient Tab Preregistered vs Examined Patients vs Archiving Info Updating Worklist Create New Study (Manual Patient Entry) Modify Patient Data Delete Patient Examination Tab: OGP Selection Acquisition mode (Alternate Programs) Exam Manager 34 Topic Trainer Trainee Initials Initials Time Adjusting / Setting Technical Factors Rad Subtask Card Fluoro Subtask Card Crop Previous / Next Series in Study Previous / Next Image in Series Post Processing Tab: Process. Sub-Task Card Graphics Sub-Task Card Rad Sub-Task Card Ortho Sub-Task Card * Documentation Tab: Marking and Unmarking Images Select Sub-Task Card Film Sub-Task Card Send Sub-Task Card Calling Uptime Service Center Cleaning Trainer Signature _________________________ Date: _________ Trainee Signature _________________________________ Date: _________ * indicates Option 35 On account of certain regional limitations of sales rights and service availability, we cannot guarantee that all products included in this brochure are available through the Siemens sales organization worldwide. Availability and packaging may vary by country and is subject to change without prior notice. Some/All of the features and products described herein may not be available in the United States. The information in this document contains general technical descriptions of specifications and options as well as standard and optional Local Contact Information features which do not always have to be Siemens Medical Solutions USA, Inc. present in individual cases. 40 Liberty Blvd. Siemens reserves the right to modify the Malvern, PA 19355-9998 design, packaging, specifications and options USA described herein without prior notice. Please Telephone: +1-888-826-9702 contact your local Siemens sales representative www.usa.siemens.com/healthcare for the most current information. Note: Any technical data contained in this Global Business Unit document may vary within defined tolerances. Siemens AG Original images always lose a certain amount Medical Solutions of detail when reproduced. X-ray Products Henkestr. 127 DE-91052 Erlangen Order No. A91SVC-17539-P1-4A00 Germany Printed in USA 02-2017 | All rights reserved Phone: +49 9131 84-4746 © 2017 Siemens Medical Solutions USA, Inc. www.siemens.com/healthcare Global Siemens Headquarters Global Siemens Healthcare Siemens AG Headquarters Wittelsbacherplatz 2 Siemens AG 80333 Muenchen Healthcare Sector Germany Henkestrasse 127 91052 Erlangen Germany Telephone: +49 9131 84-0 www.siemens.com/healthcare www.siemens.com/healthcare