MULTIX Impact: Setting Multi-Study or Single-Study Mode

This job aid will cover how to change the settings on the Impact system to
either single or multi study mode.

MULTIX Impact: Setting Multi-Study or Single Study Mode XPRF The following job aid can be used to set the system to Single Study or Multi-Study mode. These settings can be accessed by selecting the “General Settings” in the “Service” tab . • Single Study mode treats each study individually. • Multi-Study mode treats all the studies of a patient together. When selecting a study, all studies of the patient are selected. 1.) Log-in to the system as a “User” with permission to access the “Service” tab. 2.) In the “Service” tab, under “User Settings”, select the “General Setting” button. Operation Patient Tool OGP Editor Clean FD FD Archiv ... Calibration Reconnect RIS Mapping Statistics Audit Trail Test Image Examination Tube Load User Setting Site Info, General Processing Exam Setting Properties Properties Postprocessing Image Register DICOM Disk Display Config. Properties Manager User Manager Service PMS Remote Remote DICOM View Assistance Node FD Manager Sensitivity Print LifeNet PEPconnect Service Mgr 09:19:34 SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 04/24/2020 | HOOD05162003088115 Healthineers Job Aid | Multix Impact Setting Multi-Study or Single Study Mode Effective Date: 04/24/2020 | HOOD05162003088115 3.) Under “General” tab, “Patient list”, select the desired study mode. Select “Apply” and then “OK”. General Setting General Patient Result Table Columns Screen saver Waiting time 10 min Use recycle bin Yes Use USB Yes Modality image DX CR Patient list Single study mode Multi-study mode The Default Position Of Mouse Cursor In Patient Mode Name AccNo. Sample of date and time format Date 2000.01.31 Time 00:00:00 OK Apply Cancel SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 04/24/2020 | HOOD05162003088115 Healthineers Page 2 of 3 Job Aid | Multix Impact Setting Multi-Study or Single Study Mode Effective Date: 04/24/2020 | HOOD05162003088115 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and c autions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be comme rcially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Job Aid Effective Date: 04/24/2020 | HOOD05162003088115 Healthineers Page 3 of 3