MULTIX Impact: Arranging Film Sheets and Printing Images Video
This video illustrates how to arrange film sheets and print images on the MULTIX Impact Image Station software.
This video will demonstrate how to arrange film sheets, an print images in the print mode. The images are displayed on virtual sheets. Select the layout for the film sheets and adjust the size and view of each image to change the film sheet layout, click the layout icon and then drag the bottom right square to the desired layout size. In this example, the layout is changed to a two by two. There are multiple buttons that can be used to change the image size on the film sheet. To zoom in image continuously select this icon. And then drag the mouse cursor up or down in the image to pan and image select this icon and then press the left mouse button and move the mouse cursor in the image to adjust the segment. Click the image and click this icon. Then all of the images on a film sheet are adjusted to the segment to adjust the true size of all the images on the film sheet select this icon. To print images, select a printer from the list. Select the film size from the list and then enter the number of copies. Click the anonymous checkbox if necessary. If checked, know patient information will be printed on the film sheets. If necessary, click the print exam protocol checkbox. Note the exam protocol will be generated as a DICOM secondary capture image and this image will be printed in a separate film sheet. The layout for the clinical image only can be a one by one. Click the printer icon. The images are then sent to the selected device in the background. During the transfer, this icon is displayed in the bottom left corner indicating that the transfer process is running.
Patient Information Operation Filmi Patient Name: Layout Name:Anonymous Anonymous Acquisition Date:08-11-2018 00549 Acquisition Time:14:40:36 Age: 044M opr:KE Sex: Request Female Age: Tool DOB: 02-Mar-1974 Adj ust Accession No.: 00549 Images printer Printer PRINTSCP Film Size 141NX171N 1 OINX121N Copies 14.21NX141N Print exam protocol 75.2 75.6 current EX: 243.62 current EX: 313.68 current EX: 243_62 DI: -0.11 Matrix size:2065x2251 Matrix size: 1728x1961 ProtocolName:Hip Frog unilateral wc: 1530 wc: 1677 ww:61g Mgr 14:56:57 14:56:59 14:59:52 14:59:33 14:59:34 14:59:439 14:59:457 14:59:53 14:59:57
- MULTIX Impact
- Multix
- RAD 3
- Impact
- Multix
- Multx
- Impac
- MULTIX Impact Filming and Printing Images
- Filming and Printing Images