PEPconnect

nexaris Angio-CT syngo Needle Guidance Job Aid

syngo 3D Needle Guidance Job Aid nexaris Therapy Suites Plan needle path pre-operatively Plan needle path intra-operatively • Before the procedure, load the patient vol- ume from another examination (XA, CT, MR, • Acquire a DynaCT-/Dyna3D- or a CT- PET) into the 4D task card volume of a nexaris Angio-CT • Start syngo Needle Guidance Define Path + • Click + to add a needle To define the needle path, set the target and the entry point in the ....... • image • Verify that the needle path does not injure any uninvolved anatomical structure = • Close the patient. The planning result is saved for a procedure later • To start a procedure, register the patient on the Artis and load the previous planning result SIEMENS Effective Date: 04/18/2018 | HOOD05162002840053 siemens.com/healthineers Healthineers . syngo 3D Needle Guidance Job Aid | nexaris Angio-CT Effective Date: 04/18/2018 | HOOD05162002840053 Progress Needle • Perform 2D/3D or 3D/3D registration • Select a needle • Select Bull’s Eye View and drive the C-arm to Bull’s Eye View position automatically. Table adjustment markers appear on the Artis Live image. (If configured, table adjustment may be not needed for Artis zeego. If so, no table graphics are shown) • Adjust the tabletop positin so that the markers coincide. (If configured, the laser positioner light is automatically on) • Adjust and progress the needle in Bull’s Eye View, check under fluoroscopy • Select Progression View 1, 2 and drive the C-arm to Progression View 1, 2 automatically • Check the needle progression under fluoroscopy in Progression View 1, 2 • Repeat the procedure if more than one needle is defined Control Scan (optional) • Perform a (collimated) 3D acquisition • Check 3D3D registration and adjust, if needed • Check the needle position and proceed needle guidance, if needed Siemens Healthineers Services Page 2 of 3 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018

  • nexaris Angio-CT syngo Needle Guidance Job Aid